PubMed Health⌕ Search

Biomedical subjects

Sarunas Petronis

Publications and source records attributed to Sarunas Petronis.

5 recordsLinked to original sources

Transparent polymeric cell culture chip with integrated temperature control and uniform media perfusion.

Modern microfabrication and microfluidic technologies offer new opportunities in the design and fabrication of miniaturized cell culture systems for online monitoring of living cells. We used laser micromachining and thermal bonding to fabricate an optically transparent, low-cost polymeric chip for long-term online cell culture observation under controlled conditions. The chip incorporated a microfluidic flow equalization system, assuring uniform perfusion of the cell culture media throughout the cell culture chamber. The integrated indium-tin-oxide heater and miniature temperature probe linked to an electronic feedback system created steady and spatially uniform thermal conditions with minimal interference to the optical transparency of the chip. The fluidic and thermal performance of the chip was verified by finite element modeling and by operation tests under fluctuating ambient temperature conditions. HeLa cells were cultured for up to 2 weeks within the cell culture chip and monitored using a time-lapse video recording microscopy setup. Cell attachment and spreading was observed during the first 10-20 h (lag phase). After approximately 20 h, cell growth gained exponential character with an estimated doubling time of about 32 h, which is identical to the observed doubling time of cells grown in standard cell culture flasks in a CO2 incubator.

Cell Culture Techniques↗

Characterization of an inexpensive, nontoxic, and highly sensitive microarray substrate.

An agarose film has been proposed as an efficient substrate for producing microarrays. The original film preparation procedure was simplified significantly by grafting the agarose layer directly onto unmodified microscope glass slides instead of aminated glass slides, and the blocking procedure was replaced with a wash in 0.1x standard saline citrate (SSC) and 0.5% sodium dodecyl sulfate (SDS) without decreasing the performance of the produced microarrays. Characterization of the grafted agarose film using atomic force microscopy (AFM) and scanning electron microscopy (SEM) showed that the agarose film had a 10-fold increase in surface roughness compared to glass and that the interior of the agarose film was porous, with pore sizes between 100-500 nm. A comparison of hybridization on aldehyde-activated agarose-coated microarray slides and commercial amino-reactive microarray slides showed that aldehyde-activated agarose-coated slides had the highest signal-to-noise ratio of 850, suggesting that the aldehyde-activated agarose microarray slides are suitable in applications where analytes have a wide concentration range. By immobilizing the DNA probes using ultraviolet (UV) light, the signal-to-noise ratio was further increased to 3000 on the agarose microarray slides. The specificity of the UV cross-linked DNA probes was demonstrated using 21 and 25 bp long capture probes, enabling discrimination of target molecules differing in only one base.

Adsorption↗

Model porous surfaces for systematic studies of material-cell interactions.

A model system for studying cell-surface interactions, based on microfabricated cell culture substrates, has been developed and is described here. Porous surfaces consisting of interconnecting channels with openings of subcellular dimensions are generated on flat, single crystal, silicon substrates. Channel size (width, depth), distribution, and surface coating can be varied independently and used for systematic investigation of how topographical, chemical, and elastic surface properties influence cell or tissue biological responses. Model porous surfaces have been produced by using two different microfabrication methods. Submicron-sized channels with very high depth-to-width aspect ratios (up to 30) have been made by using electron beam lithography and anisotropic reactive ion etching into single-crystal silicon. Another method uses thick-resist photolithography, which can be used to produce channels wider than 1 microm and with depth-to-width aspect ratios below 20 in an epoxy polymer. Preliminary cell culture tests show that fibroblasts bridge 0.8- to 1.8-microm-wide channels with very few exceptions (i.e., a continuous space below the cell-surface interface is created). It has also been shown that variation of channel periodicity significantly affects fibroblast morphology and attachment density. With this model system, it is possible to load the channels with bioactive substances intended to interact with cells at or near the surface in a time-dependent manner.

Biocompatible Materials↗

Response of rat osteoblast-like cells to microstructured model surfaces in vitro.

The role of surface microtopography in combination with different surface wettability for rat calvaria cell differentiation was examined. Mineralization and alkaline phosphatase (ALP) activity of rat calvaria cells on flat polydimethylsiloxane (PDMS) or PDMS contained pyramids which were either hydrophilic or hydrophobic were compared. ALP expressing cells were more frequent on hydrophilic PDMS contained pyramids. ALP activity, peaked at day 9, was highest for hydrophilic pyramids followed by hydrophobic pyramids and flat hydrophilic PDMS surfaces. A similar pattern was obtained with respect to mineralized nodules. These observations showed that micro-sized surface features promote differentiation of rat calvaria cells. Further, hydrophilic surfaces are more prone to stimulate differentiation in comparison with hydrophobic surfaces. The results suggest that both material surface chemistry and topography affect osteoblast differentiation.

Alkaline Phosphatase↗

Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown: the oxide thickness, micropore configurations, surface roughness, crystal structure and chemical composition.

Titanium implants have been used widely and successfully for various types of bone-anchored reconstructions. It is believed that properties of oxide films covering titanium implant surfaces are of crucial importance for a successful osseointegration, in particular at compromized bone sites. The aim of the present study is to investigate the surface properties of anodic oxides formed on commercially pure (c.p.) titanium screw implants as well as to study 'native' oxides on turned c.p. titanium implants. Anodic oxides were prepared by galvanostatic mode in CH3COOH up to the high forming voltage of dielectric breakdown and spark formation. The oxide thicknesses, measured with Auger electron spectroscopy (AES), were in the range of about 200-1000 nm. Barrier and porous structures dominated the surface morphology of the anodic film. Quantitative morphometric analyses of the micropore structures were performed using an image analysis system on scanning electron microscopy (SEM) negatives. The pore sizes were < or = 8 microm in diameter and had 1.27-2.1 microm2 opening area. The porosity was in the range of 12.7-24.4%. The surface roughness was in the range of 0.96-1.03 microm (Sa), measured with TopScan 3D. The crystal structures of the titanium oxide were amorphous, anatase, and a mixtures of anatase and rutile type, as analyzed with thin-film X-ray diffractometry (TF-XRD) and Raman spectroscopy. The chemical compositions consisted mainly of TiO2, characterized with X-ray photoelectron spectroscopy (XPS). The native (thermal) oxide on turned implants was 17.4 nm (+/- 6.2) thick and amorphous. Its chemical composition was TiO2. The surface roughness had an average height deviation of 0.83 microm (Sa). The present results are needed to elucidate the influence of the oxide properties on the biological reaction. The results of animal studies using the presently characterized surface oxides on titanium implants will be published separately.

Crystallography, X-Ray↗