PubMed Health⌕ Search

Biomedical subjects

Sasa Mutic

Publications and source records attributed to Sasa Mutic.

At least 19 recordsLinked to original sources

Adaptive brachytherapy treatment planning for cervical cancer using FDG-PET.

PURPOSE: A dosimetric study was conducted to compare intracavitary brachytherapy using both a conventional and a custom loading intended to cover a positron emission tomography (PET)-defined tumor volume in patients with cervix cancer. METHODS AND MATERIALS: Eleven patients who underwent an [(18)F]-fluoro-deoxy-D-glucose (FDG)-PET in conjunction with their first, middle, or last brachytherapy treatment were included in this prospective study. A standard plan that delivers 6.5 Gy to point A under ideal conditions was compared with an optimized plan designed to conform the 6.5-Gy isodose surface to the PET defined volume. RESULTS: A total of 31 intracavitary brachytherapy treatments in conjunction with an FDG-PET were performed. The percent coverage of the target isodose surface for the first implant with and without optimization was 73% and 68% (p = 0.21). The percent coverage of the target isodose surface for the mid/final implant was 83% and 70% (p = 0.02), respectively. The dose to point A was higher with the optimized plans for both the first implant (p = 0.02) and the mid/last implants (p = 0.008). The dose to 2 cm(3) and 5 cm(3) of both the bladder and rectum were not significantly different. CONCLUSIONS: FDG-PET based treatment planning allowed for improved dose coverage of the tumor without significantly increasing the dose to the bladder and rectum.

Adult↗

A prospective study of differences in duodenum compared to remaining small bowel motion between radiation treatments: implications for radiation dose escalation in carcinoma of the pancreas.

PURPOSE: As a foundation for a dose escalation trial, we sought to characterize duodenal and non-duodenal small bowel organ motion between fractions of pancreatic radiation therapy. PATIENTS AND METHODS: Nine patients (4 women, 5 men) undergoing radiation therapy were enrolled in this prospective study. The patients had up to four weekly CT scans performed during their course of radiation therapy. Pancreas, duodenum and non-duodenal small bowel were then contoured for each CT scan. On the initial scan, a four-field plan was generated to fully cover the pancreas. This plan was registered to each subsequent CT scan. Dose-volume histogram (DVH) analyses were performed for the duodenum, non-duodenal small bowel, large bowel, and pancreas. RESULTS: With significant individual variation, the volume of duodenum receiving at least 80% of the prescribed dose was consistently greater than the remaining small bowel. In the patient with the largest inter-fraction variation, the fractional volume of non-duodenal small bowel irradiated to at least the 80% isodose line ranged from 1% to 20%. In the patient with the largest inter-fraction variation, the fractional volume of duodenum irradiated to at least the 80% isodose line ranged from 30% to 100%. CONCLUSION: The volume of small bowel irradiated during four-field pancreatic radiation therapy changes substantially between fractions. This suggests dose escalation may be possible. However, dose limits to the duodenum should be stricter than for other segments of small bowel.

Dose-Response Relationship, Radiation↗

FDG-PET imaging for the assessment of physiologic volume response during radiotherapy in cervix cancer.

PURPOSE: To evaluate the physiologic tumor volume response during treatment in cervical cancer using 18F-fluorodeoxyglucose positron emission tomography (FDG-PET). PATIENTS AND METHODS: This was a prospective study of 32 patients. Physiologic tumor volume in cubic centimeters was determined from the FDG-PET images using the 40% threshold method. RESULTS: The mean pretreatment tumor volume was 102 cm3. The mean volume by clinical Stages I, II, and III were 54, 79, and 176 cm3, respectively. After 19.8 Gy external irradiation to the pelvis, the reduction in tumor volume was 29% (72 cm3). An additional 13 Gy from high-dose-rate (HDR) brachytherapy reduced the mean volume to 15.4 cm3, and this was subsequently reduced to 8.6 cm3 with 13 Gy additional HDR brachytherapy (26 Gy, HDR). Four patients had physiologic FDG uptake in the cervix at 3 months after the completion of therapy. The mean time to the 50% reduction in physiologic tumor volume was 19.9 days and after combined external irradiation and HDR to 24.9 Gy. CONCLUSION: These results indicate that physiologic tumor volume determination by FDG-PET is feasible and that a 50% physiologic tumor volume reduction occurs within 20 days of starting therapy.

Adenocarcinoma, Clear Cell↗

Measurement of LINAC 90 degrees head leakage radiation TVL values.

One of the key components in modern LINAC room shielding design is the amount of 90 degrees head leakage radiation levels. With the general clinical acceptance of intensity-modulated radiation therapy (IMRT) technique, accurate knowledge of this quantity has become even more important. Measurement of 90 degrees head leakage radiation of medical linear accelerators can be technically challenging due to the low dose rate causing poor signal-to-noise ratios in most detectors. 90 degrees leakage tenth-value layer (TVL) values in concrete have not been reported for the Elekta linear accelerators. This report describes our measurements of 90 degrees leakage TVL values for 6, 10, and 18 MV x-ray beams for an Elekta Precise Treatment System. A large-volume (1000 cm3) unpressurized ionization chamber and a high sensitivity electrometer, together with a separate chamber bias power supply, were used in these measurements in order to maximize the signal-to-noise ratio. A lead enclosure, of minimum thickness 10 cm, was constructed inside the treatment room to house the ion chamber to reduce the influence of room-scattered radiation. A square aperture of 10 X 10 cm2 area was left in the shield and aimed towards the accelerator head. Measurements were performed with the chamber placed at approximately 2 m from the accelerator isocenter. Concrete slabs with individual dimensions of approximately 40 X 40 cm2 cross-sectional area and 5 cm thickness were placed between the accelerator head and the ion chamber for these measurements. The measurements were performed with total concrete thickness of up to 80 cm, so that values up to the third TVL were measured. These measurements showed thatthe first concrete TVL values are 22, 23, and 28 cm (8.6, 9.1, and 10.5 in.) for 6, 10, and 18 MV beams, while the average of the first 3 TVL's were 25, 26, and 29 cm (9.9, 10.2, and 11.5 in.). Measured values agreed to within 10% of previously reported values for Varian linear accelerators for equivalent radiation beam qualities.

Equipment Design↗

Progress toward a microradiation therapy small animal conformal irradiator.

Microradiation therapy (microRT) systems are being designed to provide conformal radiation therapy to small animals enabling quantitative radiation response evaluation. We used a Monte Carlo approach to estimate the radiation dose distributions from proposed blueprints and developed a beam model to aid in the microRT system design process. This process was applied to a prototype irradiator that uses a small (3 mm long and 3 mm in diameter), cylindrical, high-activity 192Ir source delivering the radiation beam using custom-fabricated tungsten collimators. The BEAMnrc Monte Carlo code was used to simulate dose distributions from these prototype collimators. Simulations were performed at three source-to-surface distances (50, 60, and 70 mm), and with five circular field sizes (5, 7.5, 10, 12.5, and 15 mm). A dose to a 50 X 50 X 50 mm3 water phantom with 1 X 1 X 1 mm3 voxel spacing was computed. A multiparameter dose calculation algorithm was developed to efficiently and accurately calculate doses for treatment planning exercises. The parametrization was selected so that the parameters varied smoothly as a function of depth, source-to-surface distance, and field size, allowing interpolation for geometries that were not simulated using the Monte Carlo simulation. Direct comparison of the model with the Monte Carlo simulations showed that the variations were within 5% error for field sizes larger than 10 mm, and up to 10% for smaller field sizes.

Animals↗

18F-FDG PET definition of gross tumor volume for radiotherapy of non-small cell lung cancer: is a single standardized uptake value threshold approach appropriate?

UNLABELLED: PET with (18)F-FDG has been used in radiation treatment planning for non-small cell lung cancer (NSCLC). Thresholds of 15%-50% the maximum standardized uptake value (SUV(max)) have been used for gross tumor volume (GTV) delineation by PET (PET(GTV)), with 40% being the most commonly used value. Recent studies indicated that 15%-20% may be more appropriate. The purposes of this study were to determine which threshold generates the best volumetric match to GTV delineation by CT (CT(GTV)) for peripheral NSCLC and to determine whether that threshold can be generalized to tumors of various sizes. METHODS: Data for patients who had peripheral NSCLC with well-defined borders on CT and SUV(max) of greater than 2.5 were reviewed. PET/CT datasets were reviewed, and a volume of interest was determined to represent the GTV. The CT(GTV) was delineated by using standard lung windows and reviewed by a radiation oncologist. The PET(GTV) was delineated automatically by use of various percentages of the SUV(max). The PET(GTV)-to-CT(GTV) ratios were compared at various thresholds, and a ratio of 1 was considered the best match, or the optimal threshold. RESULTS: Twenty peripheral NSCLCs with volumes easily defined on CT were evaluated. The SUV(max) (mean +/- SD) was 12 +/- 8, and the mean CT(GTV) was 198 cm(3) (97.5% confidence interval, 5-1,008). The SUV(max) were 16 +/- 5, 13 +/- 9, and 3.0 +/- 0.4 for tumors measuring greater than 5 cm, 3-5 cm, and less than 3 cm, respectively. The optimal thresholds (mean +/- SD) for the best match were 15% +/- 6% for tumors measuring greater than 5 cm, 24% +/- 9% for tumors measuring 3-5 cm, 42% +/- 2% for tumors measuring less than 3 cm, and 24% +/- 13% for all tumors. The PET(GTV) at the 40% and 20% thresholds underestimated the CT(GTV) for 16 of 20 and 14 of 20 lesions, respectively. The mean difference in the volumes (PET(GTV) minus CT(GTV) [PET(GTV) - CT(GTV)]) at the 20% threshold was 79 cm(3) (97.5% confidence interval, -922 to 178). The PET(GTV) at the 20% threshold overestimated the CT(GTV) for all 4 tumors measuring less than 3 cm and underestimated the CT(GTV) for all 6 tumors measuring greater than 5 cm. The CT(GTV) was inversely correlated with the PET(GTV) - CT(GTV) at the 20% threshold (R(2) = 0.90, P < 0.0001). The optimal threshold was inversely correlated with the CT(GTV) (R(2) = 0.79, P < 0.0001). CONCLUSION: No single threshold delineating the PET(GTV) provides accurate volume definition, compared with that provided by the CT(GTV), for the majority of NSCLCs. The strong correlation of the optimal threshold with the CT(GTV) warrants further investigation.

Carcinoma, Non-Small-Cell Lung↗

Sequential FDG-PET brachytherapy treatment planning in carcinoma of the cervix.

PURPOSE: To evaluate the utility of sequential (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) imaging for brachytherapy treatment planning in patients with carcinoma of the cervix. METHODS AND MATERIALS: Twenty-four patients with carcinoma of the cervix were included in this prospective study. The clinical stage of their disease was Ib (7), IIa (1), IIb (7), and IIIb (9). Patients were treated with irradiation and brachytherapy, with the majority receiving concurrent weekly cisplatin chemotherapy. Patients underwent diagnostic FDG-PET imaging before treatment, sequential FDG-PET brachytherapy imaging during treatment, and diagnostic FDG-PET 3 months after treatment completion. Delineation of the gross tumor volume, bladder, and rectum was performed for all scans using a commercially available treatment-planning system. Actual treatment delivery was based on two-dimensional orthogonal planning. RESULTS: The mean gross tumor volume and percent coverage by the target isodose surface for the initial, mid, and last implant were 37 cm3, 17 cm3, and 10 cm3 and 68%, 76%, and 79%, respectively. Nine of 11 patients were found to have continued decrease in tumor volume as measured by FDG-PET, with 3 patients having complete regression of their tumor before treatment was completed. The maximal bladder and rectal doses obtained from three-dimensional dose-volume histograms were significantly higher than the International Commission on Radiation Units and Measurements Report 38 bladder and rectal points obtained by two-dimensional treatment-planning. CONCLUSIONS: Sequential FDG-PET brachytherapy imaging identifies the tumor response in individual patients, potentially making patient-specific brachytherapy treatment planning possible.

Adult↗

Quantitation of the reconstruction quality of a four-dimensional computed tomography process for lung cancer patients.

We have developed a four-dimensional computed tomography (4D CT) technique for mapping breathing motion in radiotherapy treatment planning. A multislice CT scanner (1.5 mm slices) operated in ciné mode was used to acquire 12 contiguous slices in each couch position for 15 consecutive scans (0.5 s rotation, 0.25 s between scans) while the patient underwent simultaneous quantitative spirometry measurements to provide a sorting metric. The spirometry-sorted scans were used to reconstruct a 4D data set. A critical factor for 4D CT is quantifying the reconstructed data set quality which we measure by correlating the metric used relative to internal-object motion. For this study, the internal air content within the lung was used as a surrogate for internal motion measurements. Thresholding and image morphological operations were applied to delineate the air-containing tissues (lungs, trachea) from each CT slice. The Hounsfield values were converted to the internal air content (V). The relationship between the air content and spirometer-measured tidal volume (v) was found to be quite linear throughout the lungs and was used to estimate the overall accuracy and precision of tidal volume-sorted 4D CT. Inspection of the CT-scan air content as a function of tidal volume showed excellent correlations (typically r>0.99) throughout the lung volume. Because of the discovered linear relationship, the ratio of internal air content to tidal volume was indicative of the fraction of air change in each couch position. Theoretically, due to air density differences within the lung and in room, the sum of these ratios would equal 1.11. For 12 patients, the mean value was 1.08 +/- 0.06, indicating the high quality of spirometry-based image sorting. The residual of a first-order fit between v and V was used to estimate the process precision. For all patients, the precision was better than 8%, with a mean value of 5.1% +/- 1.9%. This quantitative analysis highlights the value of using spirometry as the metric in sorting CT scans. The 4D reconstruction provides the CT data required to measure the three-dimensional trajectory of tumor and lung tissue during free breathing.

Air↗

Reduction of motion blurring artifacts using respiratory gated CT in sinogram space: a quantitative evaluation.

Techniques have been developed for reducing motion blurring artifacts by using respiratory gated computed tomography (CT) in sinogram space and quantitatively evaluating the artifact reduction. A synthetic sinogram was built from multiple scans intercepting a respiratory gating window. A gated CT image was then reconstructed using the filtered back-projection algorithm. Wedge phantoms, developed for quantifying the motion artifact reduction, were scanned while being moved using a computer-controlled linear stage. The resulting artifacts appeared between the high and low density regions as an apparent feature with a Hounsfield value that was the average of the two regions. A CT profile through these regions was fit using two error functions, each modeling the partial-volume averaging characteristics for the unmoving phantom. The motion artifact was quantified by determining the apparent distance between the two functions. The blurring artifact had a linear relationship with both the speed and the tangent of the wedge angles. When gating was employed, the blurring artifact was reduced systematically at the air-phantom interface. The gated image of phantoms moving at 20 mm/s showed similar blurring artifacts as the nongated image of phantoms moving at 10 mm/s. Nine patients were also scanned using the synchronized respiratory motion technique. Image artifacts were evaluated in the diaphragm, where high contrast interfaces intercepted the imaging plane. For patients, this respiratory gating technique reduced the blurring artifacts by 9%-41% at the lung-diaphragm interface.

Air↗

Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer.

PURPOSE: Locoregional failure remains a significant problem for patients receiving definitive radiation therapy alone or combined with chemotherapy for non-small-cell lung cancer (NSCLC). Positron emission tomography (PET) with [(18)F]fluoro-2-deoxy-d-glucose (FDG) has proven to be a valuable diagnostic and staging tool for NSCLC. This prospective study was performed to determine the impact of treatment simulation with FDG-PET and CT on radiation therapy target volume definition and toxicity profiles by comparison to simulation with computed tomography (CT) scanning alone. METHODS: Twenty-six patients with Stages I-III NSCLC were studied. Each patient underwent sequential CT and FDG-PET simulation on the same day. Immobilization devices used for both simulations included an alpha cradle, a flat tabletop, 6 external fiducial markers, and a laser positioning system. A radiation therapist participated in both simulations to reproduce the treatment setup. Both the CT and fused PET/CT image data sets were transferred to the radiation treatment planning workstation for contouring. Each FDG-PET study was reviewed with the interpreting nuclear radiologist before tumor volumes were contoured. The fused PET/CT images were used to develop the three-dimensional conformal radiation therapy (3DCRT) plan. A second physician, blinded to the results of PET, contoured the gross tumor volumes (GTV) and planning target volumes (PTV) from the CT data sets, and these volumes were used to generate mock 3DCRT plans. The PTV was defined by a 10-mm margin around the GTV. The two 3DCRT plans for each patient were compared with respect to the GTV, PTV, mean lung dose, volume of normal lung receiving > or =20 Gy (V20), and mean esophageal dose. RESULTS: The FDG-PET findings altered the AJCC TNM stage in 8 of 26 (31%) patients; 2 patients were diagnosed with metastatic disease based on FDG-PET and received palliative radiation therapy. Of the 24 patients who were planned with 3DCRT, PET clearly altered the radiation therapy volume in 14 (58%), as follows. PET helped to distinguish tumor from atelectasis in all 3 patients with atelectasis. Unsuspected nodal disease was detected by PET in 10 patients, and 1 patient had a separate tumor focus detected within the same lobe of the lung. Increases in the target volumes led to increases in the mean lung dose, V20, and mean esophageal dose. Decreases in the target volumes in the patients with atelectasis led to decreases in these normal-tissue toxicity parameters. CONCLUSIONS: Radiation targeting with fused FDG-PET and CT images resulted in alterations in radiation therapy planning in over 50% of patients by comparison with CT targeting. The increasing availability of integrated PET/CT units will facilitate the use of this technology for radiation treatment planning. A confirmatory multicenter, cooperative group trial is planned within the Radiation Therapy Oncology Group.

Carcinoma, Non-Small-Cell Lung↗

Treatment planning guidelines regarding the use of CT/PET-guided IMRT for cervical carcinoma with positive paraaortic lymph nodes.

PURPOSE: Computed tomography (CT)/positron emission tomography (PET)-guided intensity-modulated radiotherapy of the paraaortic lymph nodes (PALNs) has been proposed for patients with cervical carcinoma and paraaortic metastasis. This investigation attempted to determine the guidelines regarding the selection of appropriate treatment parameters (e.g., number of beams, beam geometry) and organ-specific parameters (e.g., importance weighting and tolerance dose) for intensity-modulated radiotherapy planning for the PALNs. METHODS AND MATERIALS: Patients underwent imaging using CT and PET. The images were registered, and the structures were contoured. A goal dose of 50.4 Gy and 59.4 Gy was assigned to the clinical target volume (lymph node bed) and gross tumor volume (PET-delineated PALNs), respectively. For each patient, multiple treatment plans using various beam geometries and planning parameters were executed and evaluated in terms of the dose-volume histograms of the target and critical structures. RESULTS: Acceptable sparing of the stomach, liver, and colon was achieved, regardless of the number of beams used. Sparing of the spinal cord was strongly dependent on the number and arrangement of the beams. Varying the number and arrangement of the beams affected small intestine sparing, but the amount of sparing was limited because the small intestine overlapped the target volumes, and, therefore, received the prescription dose. Adjusting the number of beams, beam angles, and prescription parameters provided minimal improvement in kidney sparing. CONCLUSION: We successfully developed treatment plans that deliver 59.4 Gy to the positive PALNs and 50.4 Gy to the paraaortic region using CT/PET-guided intensity-modulated radiotherapy.

Female↗

A treatment planning study comparing HDR and AGIMRT for cervical cancer.

The customization of brachytherapy dose distributions for gynecologic malignancies is limited by the spatial positioning of the applicators. We tested the hypothesis that applicator-guided intensity modulated radiation therapy (AGIMRT) has the potential to deliver highly conformal dose distributions to cervical tumors, representing improvement over distributions obtained with intracavitary brachytherapy. A commercial three-dimensional (3-D) treatment planning system was used to create plans for ten cervical cancer patients treated at our institution. Dose distributions of conventionally designed high dose rate (HDR) plans were compared against those of AGIMRT. Tumor delineation was based on a previously published binary threshold technique, using image intensity on positron emission tomography (PET) scans. AGIMRT treatment schedules were designed using two fraction sizes: 6.5 Gy, to directly reproduce the HDR fractionation, and 1.8 Gy, to simulate traditional external beam fractionation. The average minimum tumor dose was significantly greater for the AGIMRT dose distributions than for the HDR distributions (64.2 Gy vs 33.6 Gy; p = 0.005). The mean percent tumor volume at the prescription dose was higher for the AGIMRT plans (90.0% vs 58.2%; p = 0.005). Using AGIMRT, the mean percent volume at the tolerance limit was decreased for the bladder (6.1% vs 16.6%; p = 0.047) but increased for the rectum (4.1% vs 2.2%; p = 0.646). Our study suggests that there may be conceptual and dosimetric advantages to replacing HDR with AGIMRT for patients with large-volume cervical tumors. This investigation is being expanded using sequential PET images to model tumor regression and compare brachytherapy and AGIMRT throughout the course of therapy.

Body Burden↗

Radiation exposure to family and household members after prostate brachytherapy.

PURPOSE: Patients with localized prostate cancer frequently seek alternatives to radical surgery and external beam radiation therapy. Permanent prostate brachytherapy is an acceptable option. However, fears of radiation exposure to family members may deter some individuals from choosing this treatment option. A direct measurement was performed to determine the expected lifetime exposure from the patient with a brachytherapy prostate implant to family members and the household. METHODS AND MATERIALS: After a permanent brachytherapy implant with (125)I or (103)Pd, patients and their family members were provided radiation monitors to measure direct radiation exposure at home. Each patient was given two monitors to wear, and each member of the household, including the spouse, children, and pets, was given a single monitor. In addition, four rooms in the house frequently occupied by the patient were monitored. Based on the reading from the dosimeters measured at the first follow-up visit, the lifetime exposure to each individual or room was calculated. Forty-four patients, along with their families, agreed to participate and complied with the use of the dosimeters. Twenty-nine patients received a (125)I implant and 15 a (103)Pd implant. Assays were obtained on 272 monitors: 78 worn by patients, 52 worn by household members, and 142 posted in rooms. RESULTS: Exposures measured by patient dosimeters were within the expected range for the type of implant received. Exposures to family members were low. Based on dosimeter readings, the calculated mean lifetime dose to a spouse from her husband was 0.1 (range: 0.04-0.55) mSv for a (125)I implant and 0.02 (range: 0.015-0.074) mSv for a (103)Pd implant. Other family or household members had 0.07 (range: 0.04-0.32) mSv or 0.02 (range: 0.015-0.044) mSv for (125)I and (103)Pd implants, respectively. The calculated lifetime exposure did not exceed the annual limit set by the U.S. Nuclear Regulatory Commission in any of the cases. The majority of room dosimeters (94%) had no detectable radiation exposure. CONCLUSIONS: Radiation exposure to family members from a patient receiving a permanent prostate brachytherapy implant with radioactive (125)I or (103)Pd is very low and well below the limits recommended by the U.S. Nuclear Regulatory Commission. Radiation exposure to members of a patient's family or to the public should not be a deterrent to undergoing this procedure.

Brachytherapy↗

PET-guided IMRT for cervical carcinoma with positive para-aortic lymph nodes-a dose-escalation treatment planning study.

PURPOSE: To evaluate a treatment planning method for dose escalation to the para-aortic lymph nodes (PALNs) based on positron emission tomography (PET) with intensity-modulated radiotherapy (IMRT) for cervical cancer patients with PALN involvement. One goal of this process was not to modify the traditional treatment of the pelvic region. METHODS AND MATERIALS: PET images for 4 cervical cancer patents with PALN involvement were registered with their corresponding CT scans. Positive PALNs were identified on PET images, and the surrounding critical structures were delineated on CT images. The treatment machine central axis (CAX) was placed at the level of the L4-L5 vertebral body interspace. There were two distinct treatment regions: the para-aortic bed superior to the CAX and the whole pelvis region inferior to the CAX. IMRT was used for treatment planning of PALN bed irradiation. The positive PALNs identified on PET images were defined as the gross target volume, and the para-aortic bed was defined as the clinical target volume. The radiation doses were escalated from the conventional 45 Gy to 59.4 Gy for the gross target volume and 50.4 Gy for the clinical target volume in 33 fractions. The pelvis area was treated with conventional treatment methods, AP-PA beams to 50.4 Gy in 28 fractions with a brachytherapy implant boost. The placement of the CAX allowed the two treatment regions to be abutted using the treatment machine's independent jaws. RESULTS: Dose escalation to positive PALNs, as identified on PET images, and the PALN bed is feasible with IMRT. Treatment plans for 4 patients revealed that escalated prescription doses could be delivered to target volumes while maintaining acceptable doses to the surrounding critical structures. Strategic placement of the treatment isocenter allows the IMRT region (PALN bed) and whole pelvis fields to be treated with a relatively uniform dose distribution in the abutment region. CONCLUSION: This study indicates that PET-guided IMRT could be used in a clinical trial in an attempt to escalate doses delivered to patients with cervical cancer who have positive PALNs.

Female↗

A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing.

Breathing motion is a significant source of error in radiotherapy treatment planning for the thorax and upper abdomen. Accounting for breathing motion has a profound effect on the size of conformal radiation portals employed in these sites. Breathing motion also causes artifacts and distortions in treatment planning computed tomography (CT) scans acquired during free breathing and also causes a breakdown of the assumption of the superposition of radiation portals in intensity-modulated radiation therapy, possibly leading to significant dose delivery errors. Proposed voluntary and involuntary breath-hold techniques have the potential for reducing or eliminating the effects of breathing motion, however, they are limited in practice, by the fact that many lung cancer patients cannot tolerate holding their breath. We present an alternative solution to accounting for breathing motion in radiotherapy treatment planning, where multislice CT scans are collected simultaneously with digital spirometry over many free breathing cycles to create a four-dimensional (4-D) image set, where tidal lung volume is the additional dimension. An analysis of this 4-D data leads to methods for digital-spirometry, based elimination or accounting of breathing motion artifacts in radiotherapy treatment planning for free breathing patients. The 4-D image set is generated by sorting free-breathing multislice CT scans according to user-defined tidal-volume bins. A multislice CT scanner is operated in the ciné mode, acquiring 15 scans per couch position, while the patient undergoes simultaneous digital-spirometry measurements. The spirometry is used to retrospectively sort the CT scans by their correlated tidal lung volume within the patient's normal breathing cycle. This method has been prototyped using data from three lung cancer patients. The actual tidal lung volumes agreed with the specified bin volumes within standard deviations ranging between 22 and 33 cm3. An analysis of sagittal and coronal images demonstrated relatively small (<1 cm) motion artifacts along the diaphragm, even for tidal volumes where the rate of breathing motion is greatest. While still under development, this technology has the potential for revolutionizing the radiotherapy treatment planning for the thorax and upper abdomen.

Adult↗

Quality assurance for computed-tomography simulators and the computed-tomography-simulation process: report of the AAPM Radiation Therapy Committee Task Group No. 66.

This document presents recommendations of the American Association of Physicists in Medicine (AAPM) for quality assurance of computed-tomography- (CT) simulators and CT-simulation process. This report was prepared by Task Group No. 66 of the AAPM Radiation Therapy Committee. It was approved by the Radiation Therapy Committee and by the AAPM Science Council.

Computer Simulation↗

Physiologic FDG-PET three-dimensional brachytherapy treatment planning for cervical cancer.

PURPOSE: To compare conventional two-dimensional (2D) orthogonal radiography-based brachytherapy treatment planning for cervical cancer with a three-dimensional (3D) treatment planning technique based on 18F-fluoro-deoxyglucose-positron emission tomography (FDG-PET). METHODS AND MATERIALS: Eleven cervical cancer patients were included in this prospective study that evaluated one tandem and ovoid brachytherapy procedure for each patient. The patient underwent FDG-PET of the pelvis to visualize the tumor followed by a second FDG-PET scan with the FDG isotope placed inside the tandem and ovoid applicators to visualize the treatment source positions for 3D treatment planning. The tumor volumes were delineated using a binary threshold technique in which the threshold FDG-PET image intensity was 40% of the peak tumor intensity. RESULTS: FDG-PET provides a reliable estimate of the cervical cancer volume and 3D spatial relationship of the tumor to the tandem and ovoid applicators. The maximal bladder and rectal doses determined from the 3D FDG-PET dose-volume histograms were found to be higher than those obtained using 2D treatment planning. The minimal dose to the tumor volume defined by FDG-PET ranged from 50 to 475 cGy for treatment plans designed to deliver 650 cGy to Point A and exhibited an inverse correlation with tumor volume. CONCLUSION: Physiologic FDG-PET brachytherapy treatment planning is feasible and accurate relative to conventional 2D treatment planning. The use of FDG-PET offers a unique method for tumor visualization and identifies the limitations of conventional brachytherapy treatment planning for coverage of large tumors and estimation of the dose to normal structures. This technique has the potential for improving isodose tumor coverage for patients with cervical cancer while sparing critical structures.

Brachytherapy↗

Toward automated quality assurance for intensity- modulated radiation therapy.

PURPOSE: To investigate whether high-quality, relatively inexpensive, document and transparency scanners used as densitometers are sufficiently quantitative for routine quality assurance (QA). METHODS AND MATERIALS: The scanner we investigated used a linear amplifier, digitizing gray-scale images to 12-bit resolution with a user-selected spatial resolution of 0.170 mm(2) pixels. To reduce Newton's rings artifacts, the standard glass platen was replaced by glass with an antireflective coating. Conversion of reading to transmission was conducted by permanently placing a calibrated photographic step tablet on the scanner platen. After conversion to light transmission, a zero-phase two-dimensional Wiener filter was used to reduce pixel-to-pixel signal variation. Light-scatter artifacts were removed by deconvolution of a measured light-spread kernel. The light-spread kernel artifacts were significant along the scanner's detector axis, but were insignificant along the scanning axis. RESULTS: Pixel-to-pixel noise was better than 2% for optical densities, ranging from 0.4 to 2.0 and 0 to 2.7 for the unfiltered and filtered images, respectively. The document scanning system response was compared against a confocal scanning laser densitometer. A series of IMRT dose distribution and dose calibration film sets were scanned using the two scanners, and the measured dose was compared. The maximum mean and standard deviation of the measured dose difference between the document scanner and confocal scanner was 1.48% and 1.06%, respectively. CONCLUSION: While the document scanners are not as flexible as dedicated film densitometers, these results indicate that, using the intensity and scatter corrections, the system provides accurate and precise measurements up to an optical density of 2.0, sufficient for routine IMRT film QA. For some film types, this requires the reduction in monitor units to limit the dose delivered to the film. The user must be cautious that the delivered IMRT dose is scaled appropriately. This inexpensive and accurate system is being integrated into an automated QA program.

Artifacts↗