PubMed Health⌕ Search

Biomedical subjects

Satoshi Inoue

Publications and source records attributed to Satoshi Inoue.

132 records · Page 8Linked to original sources

An algorithm for estimating potential deposition of corn pollen for environmental assessment.

The safety and impact on the environment of transgenic crops are important issues, and studies have shown that pollen from transgenic Bt (Bacillus thuringiensis) corn (Zea mays L.) may kill nontarget insects. To develop an algorithm for assessing the environmental effect of transgenic crops, we arranged a field experiment in Tsukuba, Japan. Pollen dispersal and deposition were measured inside and outside a cornfield throughout the flowering period. Weather conditions such as wind speed and direction were measured at the same time. Pollen dispersal peaked 1 week after the start of flowering and continued for 12 days thereafter. The variation in daily pollen dispersal was similar at all observation points. Both pollen dispersal and deposition decreased exponentially with distance from the cornfield on all days. We estimated potential pollen deposition with a quasi-mechanistic model that incorporates the effects of wind direction, wind speed, and flowering intensity. The daily potential deposition was summed over the flowering period, and then the relationship between distance from the cornfield and the integrated potential deposition was estimated. It was possible to show the effective area of the environmental risk zone posed by genetically modified pollen by combining the distance/deposition relationship with the dose/response relationship derived from a laboratory assay. The algorithm described here can be applied to various wind-pollinated plants to estimate both potential and integrated pollen deposition.

Algorithms↗

Treatable complications of cancer patients referred to an in-patient hospice.

This paper illustrates the importance of accurate diagnoses and treatments of complications in terminally ill cancer patients. The paper reports on five hospice in-patients who completely recovered from life-threatening complications; three of them had been incorrectly labeled as "imminently dying" by the referring physicians. The paper concludes that it would be beneficial for patients to receive examinations and a trial of medical treatment in their continuing treatment settings.

Adult↗

Effect of water storage on the bonding effectiveness of 6 adhesives to Class I cavity dentin.

Adhesive-dentin interfaces degrade with time. This study determined the effect water storage may have on the bonding effectiveness of adhesives to occlusal Class I cavity-bottom dentin. Six adhesives, all representing contemporary classes of adhesives, were applied: a 3-step (OptiBond FL, Kerr) and 2-step (Scotchbond 1*, 3M ESPE) etch-and-rinse adhesive, a 2-step (Clearfil SE, Kuraray) and 1-step (Adper prompt, 3M ESPE) self-etch adhesive and a 2-step (FujiBond LC, GC) and 1-step (Reactmer, Shofu) resin-modified glass-ionomer adhesive. Bonding effectiveness was assessed by microtensile bond strength testing (MTBS) and electron microscopy (Feg-SEM and TEM). The MTBS was determined after 1 day and 1 year water storage of the entire restored cavity (indirect exposure of the adhesive-dentin interface to water) and prepared microTBS-beams (direct exposure of the adhesive-dentin interface to water). The hypotheses tested were: (1) resin-dentin bonds formed at the bottom of Class I cavities resist 1-year water storage and (2) an adjacent composite-enamel bond protects the composite-dentin bond against degradation. Non-parametric Kruskal-Wallis analysis statistically analyzed the microTBSs. The first hypothesis was rejected, as only the microTBS of OptiBond FL and Clearfil SE did not significantly decrease after 1-year direct and/or indirect water storage. The second hypothesis was corroborated, as the bonding effectiveness of most simplified adhesives (Scotchbond 1, Adper Prompt, FujiBond LC and Reactmer) approached 0 (because of the frequent pre-testing failures) after 1-year direct water exposure. The second hypothesis concluded that the 3-step etch-and-rinse adhesive must still be regarded the "gold standard." Though microTBS decreased significantly, Clearfil SE, as a 2-step self-etch adhesive, was the only simplified adhesive to perform reliably after 1-year direct water exposure.

Dental Bonding↗

Buonocore memorial lecture. Adhesion to enamel and dentin: current status and future challenges.

Bonding to tooth tissue can be achieved through an "etch&rinse," "self-etch" or "glass-ionomer" approach. In this paper, the basic bonding mechanism to enamel and dentin of these three approaches is demonstrated by means of ultramorphological and chemical characterization of tooth-biomaterial interfacial interactions. Furthermore, bond-strength testing and measurement of marginal-sealing effectiveness (the two most commonly employed methodologies to determine "bonding effectiveness" in the laboratory) are evaluated upon their value and relevance in predicting clinical performance. A new dynamic methodology to test biomaterial-tooth bonds in a fatigue mode is introduced with a recently developed micro-rotary fatigue-testing device. Eventually, today's adhesives will be critically weighted upon their performance in diverse laboratory studies and clinical trials. Special attention has been given to the benefits/drawbacks of an etch&rinse versus a self-etch approach and the long-term performance of these adhesives. Correlating data gathered in the laboratory with clinical results clearly showed that laboratory research CAN predict clinical effectiveness. Although there is a tendency to simplify bonding procedures, the data presented confirm that conventional three-step etch&rinse adhesives still perform most favorably and are most reliable in the long-term. Nevertheless, a self-etch approach may have the best future perspective. Clinically, when adhesives no longer require an "etch&rinse" step, the application time, and probably more importantly, the technique-sensitivity are substantially reduced. Especially "mild," two-step self-etch adhesives that bond through a combined micromechanical and chemical interaction with tooth tissue closely approach conventional three-step systems in bonding performance.

Acid Etching, Dental↗

Effect of conditioner on bond strength of glass-ionomer adhesive to dentin/enamel with and without smear layer interposition.

The effect of a polyalkenoic acid conditioner pretreatment on the bond strength of a glass-ionomer adhesive to tooth substrates with or without smear layer was evaluated. Smear-layer covered and smear-layer free dentin and enamel surfaces were prepared from 24 extracted human molars. Resin composite was bonded to the surfaces using FujiBond LC with or without a polyalkenoic acid conditioner and subjected to microtensile bond strength (microTBS) testing. Failure modes were determined using scanning electron microscopy. For dentin, smear-layer coverage and conditioner treatment did not reveal significant differences in microTBS, which ranged from 20 to 29 MPa. For enamel, smear-layer coverage did not significantly affect microTBS, whereas, the use of conditioner significantly improved microTBS, reaching the same microTBS-values as when bonded to dentin. Regarding failure mode, most dentin specimens failed mixed adhesive cohesively. For enamel, adhesive failures mostly occurred when no conditioner was used, though mixed failures were predominant when the specimens were conditioned beforehand. Bonding of the glass ionomer adhesive to dentin can be achieved without the separate use of a polyalkenoic acid conditioner, even with the interposition of a smear layer. However, instrumented and non-instrumented enamel requires separate conditioning to provide sufficient micro-mechanical retention.

Acrylic Resins↗