Thin CdTe detector in diagnostic x-ray spectroscopy.

A CdTe Schottky diode detector of 1 mm thickness was employed in diagnostic x-ray spectroscopy. The detector response to monoenergetic photons was investigated with gamma rays from the calibration sources (241Am and 133Ba). As spectral distortion due to carrier trapping, known as tailing, was small in gamma-ray spectra, the effects of carrier trapping were not taken into account in the calculation of response functions. The distortion due to the transmission of primary x rays and the escape of secondary x rays (K-fluorescent x rays and Compton-scattered x rays) from the crystal was included in the calculated response functions. X-ray spectra corrected using the response functions were in good agreement with the reference spectra obtained with a high-purity germanium detector. The results indicated that correction for the distortion due to carrier trapping is not necessary when using a thin CdTe detector in diagnostic x-ray spectroscopy.

Cadmium Compounds↗

CdZnTe detector in mammographic x-ray spectroscopy.

A CdZnTe (CZT) detector was utilized in mammographic x-ray spectroscopy under clinical conditions. First, the detector response was investigated using y-rays from 241Am. The escape of secondary (Compton scattered and K fluorescent) x-rays and tailing due to carrier trapping were minor in the mammographic energy range. In addition, the transmission of primary x-rays was minimal from the results calculated using the mass attenuation coefficients of CZT. Therefore, spectral distortion in this energy range was expected to be negligible. Secondly, x-ray spectroscopy was carried out with the CZT detector. The measured spectra were in good agreement with the spectra obtained with the Compton-scatter method with a high-purity germanium detector. Moreover, the half-value layers (HVLs) calculated from the CZT spectra were consistent with the HVLs measured with an ionization chamber. The results indicate that a CZT detector can be utilized in mammographic x-ray spectroscopy without any corrections.

Cadmium↗

CdZnTe detector in diagnostic x-ray spectroscopy.

A method to utilize CdZnTe (CZT) detectors in diagnostic x-ray spectroscopy is described in this article. Spectral distortion due to transmission of primary x rays, the escape of cadmium- and tellurium-K fluorescent x rays, and tailing was severe in measured x-ray spectra. Therefore, correction for the distortion was performed with the stripping method using response functions. The response functions were calculated with the Monte Carlo method. The Hecht equation was employed to approximate the effects of carrier trapping in the calculations. The parameters in the Hecht equation, the mean-free path (lambda) of electrons and holes, were determined such that the tailing in calculated response functions fit that in measured gamma-ray spectra. Corrected x-ray spectra agreed well with the reference spectra measured with an HPGe detector. The results indicate that CZT detectors are suitable for diagnostic x-ray spectroscopy with appropriate corrections.

Algorithms↗

Monte Carlo calculation of depth doses for small field of CyberKnife.

PURPOSE: A Monte Carlo (MC) model of CyberKnife was developed as a quality assurance tool. The percentage depth dose (%dd) was verified by using this model. MATERIALS AND METHODS: An MC model was developed with Electron Gamma Shower version 4 (EGS4) in two steps: (1) a model of the CyberKnife treatment head and (2) a model of the collimator and phantom. The bremsstrahlung spectrum was calculated using the first model, and this spectrum was then used to calculate %dds with the second model. The calculated %dds for a large field (60 mm diameter) and three small fields (30, 15, and 5 mm diameter) were compared with those measured with a diamond detector. RESULTS AND DISCUSSION: The MC-calculated and measured %dd-curves for the 60 mm diameter field were in excellent agreement (<1.85%), thus confirming the validity of the model. Discrepancies between the calculated and measured %dd-curves increased with decreasing field size, with considerable discrepancy (11.62%) for the 5 mm diameter field due to lateral electron disequilibrium. Accurate dose can be determined with MC even in small fields. CONCLUSION: The MC technique can provide reliable standard data for accurate dose delivery with high-technology radiotherapies using small beams.