Capillary electrophoretic assay for nitrate levels in the vitreous of proliferative diabetic retinopathy.

The determination of nitric oxide (NO) in human vitreous samples is complicated by the relatively short half-life of the analyte and the viscous, high salt and protein biological matrix. In this work, we developed a fast (<5min) and useful CE method to determine the stable metabolite, nitrate, from vitreous samples. This proposed method has been successfully applied to determine the nitrate levels from the vitreous humor of patients undergoing vitrectomy for a variety of conditions. A statistically significant increase (P=0.000001) of the mean level of nitrate was observed in vitreous humor of patients with proliferative diabetic retinopathy (41.17+/-4.09microM, n=27) versus controls (15.22+/-0.86microM, n=35). The elevated levels of nitrate in the vitreous of patients known to have diabetic retinopathy suggests that NO is involved with the pathology of this disease.

Diabetic Retinopathy↗

Multiplexed detection of nitrate and nitrite for capillary electrophoresis with an automated device for high injection efficiency.

A simple automated nanoliter scale injection device which allows for reproducible 5 nL sample injections from samples with a volume of <1 microL is successfully used for conventional capillary electrophoresis (CE) and Hadamard transform (HT) CE detection. Two standard fused silica capillaries are assembled axially through the device to function as an injection and a separation capillary. Sample solution is supplied to the injection capillary using pressure controlled with a solenoid valve. Buffer solution flows gravimetrically by the junction of the injection and separation capillaries and is also gated with a solenoid valve. Plugs of sample are pushed into the space between the injection and separation capillaries for electrokinectic injection. To evaluate the performance of the injection device, several optimizations are performed including the influence of flow rates, the injected sample volume and the control of the buffer transverse flow on the overall sensitivity. The system was then applied to HT-CE-UV detection for the signal-to-noise ratio (S/N) improvement of the nitric oxide (NO) metabolites, nitrite and nitrate. In addition, signal averaging was performed to explore the possibility of greater sensitivity enhancements compared to single injections.

Automation↗

Hadamard transform CE-UV detection for biological samples.

A Hadamard transform-capillary electrophoresis-UV (HT-CE-UV) detection technique is described for the analysis of biological samples. Pseudorandom injections of sample and buffer according to a simplex matrix obtained from the corresponding Hadamard matrix is performed with conventional capillaries. Alternating injections are achieved with a novel capillary "T" connector created by drilling conventional capillary dimensions through a 1-cm diameter polycarbonate disc. This connector design coupled with a switching system allows for rapid, electrokinetic injections of solution into alternating sample and buffer capillary arms for UV detection. The standard mixtures of nitric oxide (NO) metabolites, nitrite and nitrate, dissolved in physiological saline solution are injected into the separation capillary according to an 83-element injection sequence to obtain a signal-to-noise ratio (S/N) enhancement of ca. 4.5 over a single injection. Nitrite, being the less concentrated metabolite in NO detection and thereby more difficult to detect, was calibrated with the HT-CE-UV method and a limit of detection (LOD) of 0.56 microM was obtained. Rat blood plasma was analyzed with this detection system and demonstrated to be comparable with NO metabolite concentrations of previously published results. This HT-CE-UV method is described where a unique reservoir tube design that contains 8-microL standard nitrite sample volumes is placed over the end of the capillary arm to explore low volume limits for biological samples.

Animals↗

MALDI-TOF MS detection of dilute, volume-limited peptide samples with physiological salt levels.

This paper presents a highly efficient sample preparation technique for matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The purpose of the research is to use a conventional MALDI support to directly and conveniently detect sub-nM levels of peptides from volume-limited samples with physiological salt levels. In this new method, highly uniform matrix-nitrocellulose spots with a 500 microm diameter were conveniently generated by direct contact of a capillary tip to a stainless steel MALDI plate. An array of 50 microspots can be blotted from 1 microL matrix-nitrocellulose solution within 1 min. It was found that the addition of high concentration nitrocellulose to the alpha-cyano-4-hydroxycinnamic acid (CHCA) matrix solution is critical for the formation of microspots. Samples are deposited on top of those microspots and incubated for 3 min. The CHCA-nitrocellulose surface shows a significant peptide binding capability for sub-nM levels of peptide. Restricting the matrix spot diameter to 500 microm gives an analyte enrichment effect because the peptides are confined to a small solid-phase surface area. Selective peptide binding is seen even with >0.15 M salt levels. Loading small aliquots of samples with multiple applications allows low level peptide detection down to 100 pM. Push-pull perfusates collected from the rat striatum were successfully analyzed with the microspot method.

Animals↗

Comparison of Hadamard transform and signal-averaged detection for microchannel electrophoresis.

A Hadamard transform (HT) detection method for microchip capillary electrophoresis with laser-induced fluorescence and a charge-coupled device (CCD) is described and compared to signal-averaged detection. A low-noise CCD camera is used to image a section of a separation channel where each camera pixel can be thought of as a unique detector. For signal averaging, electropherograms corresponding to individual pixels can be averaged for improved S/N. HT detection is performed on each pixel electropherogram to generate a contour plot electropherogram. The multiple injections required for HT provides an enhancement at the cost of longer times for the pseudorandom injection sequences. A short sample injection length of 0.25 s is used to reduce the overall analysis time and improve sensitivity compared to previously published results. An injection sequence is performed on the microchip that is based on a cyclic S-matrix of 513 elements that generates an 8-fold improvement in S/N compared to a single injection. This spatially resolved HT detection method is also capable of performing a multicomponent separation. Signal-averaged HT and single-injection data are compared to experimental HT and single-injection results. The unique capabilities of each method are described.

Journal Article↗

Competitive immunoassay for microliter protein samples with magnetic beads and near-infrared fluorescence detection.

A competitive immunoassay with near-infrared (NIR) fluorescence detection to analyze microliter biological samples with an amol limit of detection (LOD) is described. An important feature about this technique is that the immunoreaction and fluorescence detection are separated into two distinct steps, allowing for independent optimization. In the immunoreaction step, NIR fluorescence-labeled antigen (Ag) competes with the unlabeled analyte (Ag) for antibodies (Ab) immobilized on the surface of paramagnetic beads. A magnet is then used to separate the bound antigen from the free in the supernatant. As the amount of Ag in the sample increases, there is less binding between Ag and immobilized Ab; therefore, the amount of Ag in the supernatant is proportionally related to the amount of Ag in the sample. In the fluorescence detection step, aliquots of the supernatant are concentrated onto a protein binding membrane by a capillary blotting technique with an optimized 33 nL/min flow rate. The fluorescence of the blotted spots is detected with a NIR sensitive photon counting system that is optimized to an instrumental LOD of 30 000 fluorophore molecules. This competitive assay demonstrates a sample LOD of 400 pg/mL of unlabeled rabbit immunoglobulin G spiked into bovine serum. This design features low sample volumes and reagent consumption.

Animals↗

Determination of nitrate and nitrite in rat brain perfusates by capillary electrophoresis.

A fast and simple method for the direct, simultaneous detection of nitrite (NO(2) (-)) and nitrate (NO(3) (-)) in rat striatum has been developed using a capillary electrophoresis separation of low-flow push-pull perfusion samples. The method was optimized primarily for nitrite because nitrite is more important physiologically and is found at lower levels than nitrate. We obtained a complete separation of NO(2) (-) and NO(3) (-) in rat striatum within 1.5 min. Optimal CE separations were achieved with 20 mM phosphate, 2 mM cetyltrimethylammonium chloride (CTAC) buffer at pH 3.5. The samples were injected electrokinetically for 2 s into a 40 cm x 75 microm ID fused-silica capillary. The separation voltage was 10 kV (negative polarity), and the injection voltage was 16 kV (negative polarity). UV detection was performed at 214 nm. The limits of detection obtained at a signal-to-noise ratio (S/N) of 3 for nitrite and nitrate were 0.96 and 2.86 microM. This is one of the fastest separations of nitrite and nitrate of a biological sample ever reported. Interference produced by the high physiological level of chloride is successfully minimized by use of CTAC in the run buffer.

Animals↗

Determination of amino acids in rat vitreous perfusates by capillary electrophoresis.

In vivo determinations of amino acids are important for improving our understanding of physiological states of biological tissue function and dysfunction. However, the chemically complex matrix of different biological fluids complicates the assay of this important class of molecules. We introduce a method for characterizing the amino acid composition of submicroliter volumes of vitreous humor perfusates. Low-flow push-pull perfusion sampling is compatible with collecting small volume samples in a complicated matrix that are potentially difficult to separate. An efficient, sensitive, and rapid analysis of amino acids from in vivo perfusates of the vitreous is presented with 3-(4-carboxybenzoyl)-2-quinoline-carboxaldehyde (CBQCA) derivatitation and capillary electrophoresis (CE) separation with laser-induced fluorescence detection (LIF). Derivatization with CBQCA for up to 2 h provided high sensitivity and low detection limits at the nM level. Seventeen amino acids including D-serine (D-Ser) and D-aspartate (D-Asp) were resolved in less than 10 min. Importantly, D-Ser is separated from its enantiomeric pair. Characterization of vitreal amino acids with this assay technique will be useful for understanding ocular diseases and physiological mechanisms in vision.

Amino Acids↗

Solid-phase immunoassay detection of peptides from complex matrices without a separation.

A simple and sensitive solid-phase fluorescence immunoassay method was developed to detect peptides without separating them from a biological matrix. A near infrared fluorescence detection system was constructed for scanning analyte spots blotted onto protein binding membranes. Hydrophobic membranes were used with a modified vacuum spot blotting system to concentrate the peptide solution into a small area and the overall assay time was thus reduced by eliminating blocking steps. Both direct and indirect immunoassay methods are demonstrated; the indirect is more sensitive and features a 1 pmol detection limit of neat dynorphin A solutions. To further increase the immunoassay sensitivity, a novel capillary blotting system with hydrophilic membranes was designed where optimized sample volumes of 167 nL were deposited for each spot. The area-reduced blotting method shows a 1000-fold improved, 1.3 fmol spot(-1) detection limit of a dynorphin A diluted in a buffered solution of 150 mg L(-1) of casein. Low-flow push-pull perfusates with volumes of 1 microL sampled from the striatum of the rat were assayed for dynorphin A by the method of standard addition. The detection limit was estimated to be 1.9 fmol in the low-flow push-pull perfusates. These data demonstrate a solid-phase near infrared immunofluorescence strategy for the study of peptides directly blotted from chemically complex biological fluid matrices.

Dynorphins↗

Demonstration of low flow push-pull perfusion.

Methods to follow in vivo chemical composition provide information regarding the processes of intercellular communication. There is a need for methods that provide chemical information from small volumes of the central nervous system (CNS) without sacrificing neurochemical recovery. One method that offers potential for providing such information is push-pull perfusion. In this study a low flow push-pull perfusion system is introduced that provides high (70-80%) in vitro recoveries. A concentric probe design is used with a 27-gauge stainless steel outer cannula for saline infusion and an inner fused silica capillary for fluid withdrawal. Flow rates of 10-50 nl/min were reliably generated and were well matched in vitro. Sampling was performed in the striatum of an anesthetized rat generating a 0.5 microl sample every 12 min. Capillary electrophoresis was used to determine glutamate levels in each sample; the basal level was found to be 1.97+/-0.70 microM. The method described was also demonstrated to deliver L-trans-pyrrolidine-2,4-dicarboxylic acid through the perfusion solution while sampling. Post-sampling histological analysis demonstrates little tissue disturbance to the sampled region. These data provide evidence that low flow push-pull method is a viable alternative for studying neurochemical signaling in the CNS.

Animals↗

Shah and sine convolution Fourier transform detection for microchannel electrophoresis with a charge coupled device.

This paper describes an improved format for Shah convolution Fourier transform (SCOFT) detection that utilizes the spatial resolution of a charge-coupled device (CCD) rather than a fixed optical mask to perform a Shah or sine convolution over a fluorescence signal. The laser-induced fluorescence from a 9-mm section of microfabricated channel is collected with a CCD at 28 Hz. Each image frame is multiplied by a convolution function to modulate the collected signal through space. Each frame is then summed to generate an intensity-versus-time data set for Fourier analysis. The fluorescence signal oscillates at a frequency dependent upon both the convolution function multiplied across each data frame and the velocity of fluorescent microspheres or a plug of fluorescent dye flowing through the channel. This SCOFT technique affords more flexibility over formats that employ a physical mask and provides data that can be optimized for signal-to-noise (S/N) or resolution information. A 1,000-fold improvement in S/N is demonstrated for a plug of fluorescein dye. Detection of fluorescent beads exhibited frequency signals that were dependent upon the bead size distribution, the electric field, and the electrophoresis buffer concentration. Data are presented demonstrating the quantitation of fluorescent microspheres.

Journal Article↗