PubMed Health⌕ Search

Biomedical subjects

Scott A Yerby

Publications and source records attributed to Scott A Yerby.

14 recordsLinked to original sources

Methodological approaches to developing criteria for improvement in lumbar spinal stenosis surgery.

STUDY DESIGN: The study design was an outcomes measure validation for overall patient success. OBJECTIVE: The objective of this study was to validate an established lumbar spinal stenosis outcomes measure for individual patient success. SUMMARY OF BACKGROUND DATA: The Brigham Spinal Stenosis (BSS) Questionnaire has been used to evaluate lumbar spinal stenosis patients since the early 1990s. The three-domain questionnaire has been previously validated for patient improvement in each domain, but criteria for overall patient success have not been established. METHODS: The sample consisted of preoperative and 24-month postoperative BSS scores from 197 individuals who had undergone a lumbar decompressive procedure with or without an instrumented fusion. For each of the three BSS domains, we determined a threshold score that marked a successful outcome in that domain using receiver operator characteristic (ROC) curves. We combined these threshold scores in different ways to produce varying definitions of overall surgical success. RESULTS: The threshold for changes in the Symptom Severity and Physical Function domain scores were calculated as 0.46 and 0.42, respectively, while for Patient Satisfaction it was 2.42 based on the ROC analysis. The definition for individual patient success that requires the patient achieve threshold scores in each domain was less sensitive but more specific than alternative definitions of overall success that required the patient achieve at least two criteria or at least one criterion. CONCLUSIONS: The threshold values for each domain were similar to previously established values and the most balanced definition of overall success required that a patient achieve at least two criteria.

Aged↗

Distal biceps tendon repair: a biomechanical comparison of intact tendon and 2 repair techniques.

BACKGROUND: A variety of techniques have been described for distal biceps tendon reattachment-bone tunnel with transosseous sutures, suture anchors, and interference screw techniques. HYPOTHESIS: There will be no significant difference between the mean failure strength, maximum strength, and stiffness of the intact specimen and repair techniques tested: bone tunnel with transosseous sutures and interference screw. STUDY DESIGN: Controlled laboratory study. METHODS: Nine matched pairs of fresh-frozen human cadaveric elbows were prepared. The intact tendon was pulled from the radial tuberosity; the right and left elbows were randomized to bone tunnels with transosseous sutures or interference screw repair techniques. The repaired specimens were pulled using the same regimen for the intact tendon. Failure strength, maximum strength, and stiffness were measured and compared. RESULTS: The mean failure strength, maximum strength, and stiffness of intact tendons were 204.3 +/- 76.9 N, 221.7 +/- 65.9 N, and 30.1 +/- 12.4 N/mm, respectively; for the interference screw specimens, 178.0 +/- 54.5 N, 192.1 +/- 53.1 N, and 30.4 +/- 9.5 N/mm, respectively; and for the bone tunnel specimens, 124.9 +/- 22.8 N, 206.6 +/- 49.8 N, and 15.9 +/- 5.6 N/mm, respectively. There were no significant differences between measures in the intact and interference screw specimens. Mean failure strength and stiffness of the bone tunnel specimens were significantly lower than those of the intact and interference screw specimens; there was no significant difference between the maximum strengths of the treatments. Interference screw failure occurred abruptly with little plastic deformation in nearly all specimens with the tendon and screw pulling out as a unit, often involving fracture of the radial wall. Two of the bone tunnels failed at the bony bridge; the remainder lost bone-tendon contact as the distal tendon was shredded by the suture. CONCLUSION: The results suggest interference screw fixation repair is nearly as strong and stiff as the intact tendon and stronger than the bone tunnel repair technique. CLINICAL RELEVANCE: The interference screw provides better stiffness and failure strength compared with the bone tunnel technique for distal biceps tendon repair. Given the superior mechanical properties, the interference screw technique is recommended as the treatment of choice for biceps tendon rupture repair.

Aged↗

Patient-based outcomes for the operative treatment of degenerative lumbar spinal stenosis.

STUDY DESIGN: A retrospective surgical case series was conducted using a condition-specific, patient-based outcomes assessment. OBJECTIVE: The goal of this study was to describe the outcome predictors of decompressive surgery for degenerative lumbar spinal stenosis (DLSS). SUMMARY OF BACKGROUND DATA: Surgical decompression is the recommended treatment for patients with moderate to severe DLSS. Previous studies have reported that factors such as the number of operated levels and patient health status are predictors of surgical outcomes. METHODS: This study analyzed the success rates of 58 DLSS patients treated with decompressive surgery. Outcomes were measured with the Zurich Claudication Questionnaire (ZCQ) completed pre-operatively and at least 12 months post-operatively (range 12-54 months). The ZCQ includes three distinct domains that involve symptom severity, physical function, and patient satisfaction. Variables such as age, sex, pre-operative symptom severity, and arthrodesis were analyzed as predictors of success. RESULTS: The study group included 21 males and 37 females, and the mean age of all patients was 66 years (range 41-80 years). Overall, 63.8% of the patients had significant clinical improvement in Symptom Severity, 55.2% had significant clinical improvement in Physical Function, and 58.6% of the patients were at least somewhat satisfied; 63.8% (37/58) of the patients were considered to be clinically successful. Patients with more severe pre-operative symptoms and more physical function restrictions had better success results than those patients with milder symptoms and less restrictive physical function. Also, patients who were followed for less than 24 months had better success than those followed for more than 24 months. There was no significant difference in the clinical success rates of (1) patients who were fused and those not fused, (2) males and females, (3) patients aged less than 65 years and those greater than 65 years, and (4) patients who were treated at one or two levels and those treated at three or four levels. CONCLUSION: The results of this retrospective study indicate that operative decompression of the lumbar spine offers significant improvement for patients with DLSS. Although not all comparisons were statistically significant, there was a trend for DLLS patients aged less than 65 years with more severe pre-operative symptoms and physical function disturbances treated at one or two levels with a laminectomy and fusion to have the best outcomes.

Adult↗

The use of an interspinous implant in conjunction with a graded facetectomy procedure.

STUDY DESIGN: The range of motion (ROM) of lumbar cadaver spines was measured during flexion, extension, axial rotation, and lateral bending following graded facetectomies and implantation of an X STOP interspinous spacer implant. OBJECTIVE: The study was performed undertaken to understand better the influence of the interspinous spacer implant on the kinematics of the lumbar spine following graded facetectomies. SUMMARY OF THE BACKGROUND DATA: Lateral lumbar spinal stenosis is often treated with a unilateral or bilateral facetectomy procedure. Previous biomechanical research has shown that a facetectomy may increase the ROM during flexion and axial rotation. METHODS: Seven cadaver spines (L2-L5) were tested in flexion, extension, axial rotation, and lateral bending, and the individual ROM of each motion segment was measured. Specimens were tested intact and following 3 graded facetectomies (i.e., unilateral medial facetectomy [UMF], unilateral total facetectomy [UTF], and bilateral total facetectomy [BTF]), with and without the X STOP. RESULTS: A BTF caused a significant increase in ROM during flexion and axial rotation but not extension and lateral bending. The UMF and UTF did not affect the ROM during any of the 4 motions. The interspinous implant: (1) significantly decreased the flexion ROM for the intact, UMF, UTF, and BTF treatments; (2) significantly decreased the extension ROM for the intact, UMF, and BTF treatments but not the UTF (P < 0.13); (3) had no significant effect on the axial rotation ROM; and (4) significantly increased the lateral bending ROM for the UMF, UTF, and BTF treatments. CONCLUSIONS: The results suggest that the implant may be used in conjunction with a UMF or UTF. However, the X STOP should not be used in conjunction with BTF.

Biomechanical Phenomena↗

Insertion loads of the X STOP interspinous process distraction system designed to treat neurogenic intermittent claudication.

An interspinous process implant has been developed to treat patients suffering from neurogenic intermittent claudication secondary to lumbar spinal stenosis. As most patients who suffer from spinal stenosis are over the age of 50 and may have weaker bones, it is imperative to know how bone mineral density (BMD) correlates with lateral spinous process strength. The study was undertaken to characterize the lateral failure loads of the spinous process, correlate the failure loads to BMD, and compare the failure loads to the loads required to insert an interspinous process implant. Spinous process lateral failure loads were assessed, correlated to BMD, and compared to the loads required to insert an interspinous process implant. Mean spinous process failure loads were significantly greater than the lateral insertion load of the interspinous process implant. There was a significant relationship between the BMD and spinous process failure load. The technique used to insert the interspinous implant poses little risk to spinous process failure. There is ample margin of safety between the insertion loads and spinous process failure loads. The significant relationship between BMD and spinous process failure load suggests that patients with lower BMD must be approached with more caution during the implant insertion procedure.

Biomechanical Phenomena↗

The effect of an interspinous process implant on facet loading during extension.

STUDY DESIGN: Facet loading parameters of lumbar cadaver spines were measured during extension before and after placement of an interspinous process implant. OBJECTIVE: The study was undertaken to quantify the influence of an interspinous implant on facet loading at the implanted and adjacent levels during extension. SUMMARY OF BACKGROUND DATA: Facet loading is increased during extension and decreased during flexion. Previous studies have demonstrated that interspinous process decompression relieves disc pressure at the implanted level and does not alter disc pressure at the adjacent levels. Facet joints are believed to play a key role in back pain, especially in patients with collapsed discs and increased motion segment mobility resulting in increased facet loading. METHODS: Seven cadaver spines (L2-L5) were loaded to 15 Nm of extension and 700 N compression with and without an interspinous process implant (X STOP) placed between the L3-L4 spinous processes. Pressure-sensitive film was placed in the facet joints of the implanted and adjacent levels. After loading, the film was digitally analyzed for peak pressure, average pressure, contact area, and force. These values were compared between the intact and implanted specimens at the adjacent and implanted levels using a paired t test (P < 0.05). RESULTS: The implant significantly reduced the mean peak pressure, average pressure, contact area, and force at the implanted level. The mean peak pressure, average pressure, contact area, and force at the adjacent levels were not significantly different between the intact and implanted specimens with the exception of contact area at the L2-L3 level. CONCLUSIONS: Interspinous process decompression will unlikely cause adjacent level facet pain or accelerated facet joint degeneration. Furthermore, pain induced from pressure originating in the facets and/or posterior anulus of the lumbar spine may be relieved by interspinous pro-cess decompression. Clinical results from patients with a component of lower back pain suggest that this is a valid conclusion.

Cadaver↗

The treatment mechanism of an interspinous process implant for lumbar neurogenic intermittent claudication.

STUDY DESIGN: The spinal canal and neural foramina dimensions of cadaver lumbar spines were quantified during flexion and extension using magnetic resonance imaging before and after placement of an interspinous process implant. OBJECTIVE: To quantify the effect of the implant on the dimensions of the spinal canal and neural foramina during flexion and extension. SUMMARY OF THE BACKGROUND DATA: Lumbar neurogenic intermittent claudication symptoms are typically exacerbated during extension and relieved during flexion. It is understood that the dimensions of the spinal canal and neural foramen increase in flexion and decrease in extension. The authors hypothesized that an interspinous process implant would significantly prevent narrowing of the canal and foramina in extension and have no significant effect in flexion. METHODS: Eight L2-L5 specimens were positioned to 15 degrees of flexion and 15 degrees of extension using a positioning frame. Each specimen was magnetic resonance imaged with and without an interspinous implant (X STOP) placed between the L3-L4 spinous processes. Canal and foramina dimensions were compared between the intact and implanted specimens using a repeated measures analysis of variance with a level of significance of 0.05. RESULTS: In extension, the implant significantly increased the canal area by 18% (231-273 mm), the subarticular diameter by 50% (2.5-3.7 mm), the canal diameter by 10% (17.8-19.5 mm), the foraminal area by 25% (106-133 mm), and the foraminal width by 41% (3.4-4.8 mm). CONCLUSIONS: The results of this study show that the X STOP interspinous process implant prevents narrowing of the spinal canal and foramina in extension.

Cadaver↗

The behavior of thoracic trabecular bone during flexion.

Thoracic compression fractures are often described as anterior wedge fractures. Although the radiographic signs of these fractures are easily identified, the mechanism of the trabecular failure is not well understood. The current study addressed this mechanism in the lower thoracic spine by measuring the trabecular strain. Trabecular strain was measured in six human thoracic cadaver spines during 1) compressive and 2) flexural loading. The strains were measured at incremental loads using a texture correlation. They were analyzed by global contour plots and regional analysis of the T11 vertebrae. Specimens loaded under only compression exhibited uniform strains in the vertebral body. During flexion, however, the strains were concentrated in the anterosuperior margin of the vertebral body and the compressive and shear strain magnitudes in this region were significantly increased. These results demonstrate that the flexural position places the lower thoracic spine at greater risk of anterior compression fracture as seen clinically.

Aged↗

Gigantism and comparative life-history parameters of tyrannosaurid dinosaurs.

How evolutionary changes in body size are brought about by variance in developmental timing and/or growth rates (also known as heterochrony) is a topic of considerable interest in evolutionary biology. In particular, extreme size change leading to gigantism occurred within the dinosaurs on multiple occasions. Whether this change was brought about by accelerated growth, delayed maturity or a combination of both processes is unknown. A better understanding of relationships between non-avian dinosaur groups and the newfound capacity to reconstruct their growth curves make it possible to address these questions quantitatively. Here we study growth patterns within the Tyrannosauridae, the best known group of large carnivorous dinosaurs, and determine the developmental means by which Tyrannosaurus rex, weighing 5,000 kg and more, grew to be one of the most enormous terrestrial carnivorous animals ever. T. rex had a maximal growth rate of 2.1 kg d(-1), reached skeletal maturity in two decades and lived for up to 28 years. T. rex's great stature was primarily attained by accelerating growth rates beyond that of its closest relatives.

Biological Evolution↗

The effects of an interspinous implant on the kinematics of the instrumented and adjacent levels in the lumbar spine.

STUDY DESIGN: Measurement of the kinematics of the lumbar spine after insertion of an interspinous spacer in vitro. OBJECTIVES: To understand the kinematics of the instrumented and adjacent levels due to the insertion of this interspinous implant. SUMMARY OF BACKGROUND DATA: An interspinous spacer (X Stop, SFMT, Concord, California) has been developed to treat neurogenic intermittent claudication by placing the stenotic segment in slight flexion and preventing extension. This restriction of motion by the interspinous implant may affect the kinematics of levels adjacent to the instrumented level. METHODS: Seven lumbar spines (L2-L5) were tested in flexion-extension, lateral bending, and axial rotation. Images were taken during each test to determine the kinematics of each motion segment. The interspinous implant was placed at the L3-L4 level, and the test protocol was repeated. RESULTS: The flexion-extension range of motion was significantly reduced at the instrumented level. Axial rotation and lateral bending ranges of motion were not affected at the instrumented level. The range of motion in flexion-extension, axial rotation, and lateral bending at the adjacent segments was not significantly affected by the implant. CONCLUSIONS: The implant does not significantly alter the kinematics of the motion segments adjacent to the instrumented level.

Adolescent↗

The effects of an interspinous implant on intervertebral disc pressures.

STUDY DESIGN: Measurement of intradiscal pressure was performed after placement of an interspinous implant in a cadaver model. OBJECTIVE: To understand the likelihood of accelerated adjacent-level disc degeneration as a result of the implant. SUMMARY OF BACKGROUND DATA: An interspinous implant has been developed to treat lumbar neurogenic claudication secondary to spinal stenosis that places the stenotic segment in slight flexion and prevents extension. Previous biomechanical studies demonstrated that fusing one level may significantly increase the intradiscal pressures at adjacent levels. Moreover, clinical studies have reported an increased incidence of adjacent-level degeneration after lumbar spinal fusion. METHODS: Eight cadaver lumbar specimens (L2-L5) were loaded in flexion, neutral, and extension. A pressure transducer measured intradiscal pressure and annular stresses during each of the three positions at each of the three disc levels. An appropriately sized implant was placed at L3-L4, and the pressure measurements were repeated. RESULTS: The pressures at the adjacent discs were not significantly affected by the interspinous implant insertion. There was a significant decrease in intradiscal pressure at the L3-L4 disc in the posterior annulus and nucleus in the neutral and extended positions. CONCLUSIONS: The implant does not significantly change the intradiscal pressures at the adjacent levels, yet it significantly unloads the intervertebral disc at the instrumented level in the neutral and extended positions. On the basis of the current findings, it does not appear that the implant causes accelerated disc degeneration at the adjacent levels.

Aged↗

Posterior stabilization at the cervicothoracic junction: a biomechanical study.

STUDY DESIGN: This study biomechanically evaluated three fixation devices for stability with posterior two- and three-column injuries. OBJECTIVES: To find an effective means of posteriorly stabilizing injuries at the cervicothoracic junction. SUMMARY OF BACKGROUND DATA: The cervicothoracic spine is complex anatomically and has been a difficult challenge in approach and stabilization of traumatic and degenerative disorders. METHODS: Twenty-one human cadaveric spines (C3-T3) were loaded in flexion, extension, lateral bending, and axial torsion. A posterior two-column injury was created at C7-T1. One of three posterior fixation systems was applied (two rod-screw systems, one plate-screw system, all with screws at C5, C6 and T1, T2). The spines were tested again. A three-column injury was created by transecting the remaining anterior structures; the spines were tested a final time. RESULTS: In flexion-extension, there were no significant differences in stiffness between intact and instrumented two-column injury specimens for all systems; the instrumented three-column injury was significantly (P < 0.05) less stiff than intact specimens in extension. Ranges of motion and neutral zones decreased from intact to instrumented two-column injuries and increased from intact to three-column constructs. In lateral bending and axial rotation, all systems were stiffer than intact spines for both injuries; ranges of motion and neutral zones were reduced for both injuries compared with intact specimens. CONCLUSION: All three systems stabilize the cervicothoracic junction with a posterior two-column injury in flexion-extension, lateral bending, and axial rotation; none was adequate for a three-column injury, particularly in extension. A three-column injury at this level would warrant supplemental anterior fixation.

Adult↗

Comparative morphometry of L4 vertebrae: comparison of large animal models for the human lumbar spine.

STUDY DESIGN: Anatomic analysis of L4 vertebral morphometry comparing specimens harvested from humans and five common large animal species. OBJECTIVE: To compare fundamental structural similarities and differences in the vertebral bodies of commonly used experimental animals relative to human vertebrae. SUMMARY OF BACKGROUND DATA: Animal models are commonly used for assessment of spine fusion, instrumentation techniques, and vertebral bone biology. Among the animals used, the lumbar vertebrae exhibit considerable anatomic variability. The goal of this study was to determine which of the animals commonly used for spine research is best suited as an anatomic model for the human lumbar spine. METHODS: Morphometric features of the L4 vertebrae of five common research animals were compared with those of the human L4 vertebrae. Mature canines, immature pigs, mature micropigs, mature dairy goats, and mature sheep were analyzed. These species were chosen because they are commonly selected research animals, and most research facilities do not need to be modified to use them. The samples included ten L4 vertebrae of each animal species and seven human L4 vertebrae. Each specimen was meticulously cleaned of all soft tissue. The measurements were grouped into vertebral body parameters, neural canal dimensions, and pedicle and facet morphometery. The mean of each anatomic measurement was compared using a single factor analysis of variance and a Scheffe's post hoc test, with 0.05 denoting significance. RESULTS: The human vertebral body was significantly wider and deeper in the anteroposterior plane than any of the animals studied. However, the mean vertebral body height of the sheep and goat significantly exceeded that of the human specimens. The mean pedicle angle of every animal species was significantly greater than that of the human. The mean pedicle width of the micropig and goat were significantly narrower than the human pedicles, and the dog specimens lacked a definable pedicle altogether. There was no significant difference in mean pedicle width between any of the remaining species and the human specimens. Facet tropism and radius of curvature of the sheep and goat specimens differed significantly from the remaining selections. CONCLUSIONS: When posterior pedicle instrumentation is part of a testing protocol, the increased pedicle angle and lack of vertebral body depth found in all animals studied must be kept in mind. In addition, when testing interbody cages designed to stabilize the spine and promote fusion, one must be aware of the decreased vertebral body depth and width in these animals, as compared with humans. Physeal defects in the immature pig may alter specific biomechanical results during failure or fatigue testing, or in basic studies of vertebral bone material properties. In all cases, instrumentation and hardware must be sized appropriately to the selected model to provide meaningful results.

Age Factors↗

Failure and fatigue characteristics of adhesive athletic tape.

PURPOSE: Athletic tape has been commonly reported to lose much of its structural support after 20 min of exercise. Although many studies have addressed the functional performance characteristics of athletic tape, its mechanical properties are poorly understood. This study examines the failure and fatigue properties of several commonly used athletic tapes. METHODS: A Web-based survey of professional sports trainers was used to select the following three tapes for the study: Zonas (Johnson & Johnson), Leukotape (Beiersdorf), and Jaylastic (Jaybird & Mais). Using a hydraulic material testing system (MTS), eight samples of each tape were compared in three different mechanical tests: load-to-failure, fatigue testing under load control, and fatigue testing under displacement control. Differences in tape microstructure were used to interpret the results of the mechanical tests. RESULTS: Significant differences (P < 0.001) in failure load, elongation at failure, and stiffness were found from failure tests. Significant differences were also found (P < 0.001) in fatigue behavior under both modes of control. As a representative example, in one normalized displacement control fatigue test after 20 min of cycling, 21% (Zonas), 29% (Leukotape), and 57% (Jaylastic) of the mechanical support was lost. After cycling, all tapes loaded to failure showed increased stiffness (P < 0.001), indicating significant energy absorption during cycling. Observed differences in the tapes' microstructure were qualitatively consistent with the measured differences in their mechanical properties. CONCLUSION: In understanding the shortcomings of currently available tapes, the results of these tests can now be used as benchmarks with which to compare and develop future tape designs. Ultimately, these improved tapes should reduce ankle injuries among athletes.

Adhesives↗