Scott B Reeder

Publications and source records attributed to Scott B Reeder.

At least 19 recordsLinked to original sources

Articular cartilage of the knee: rapid three-dimensional MR imaging at 3.0 T with IDEAL balanced steady-state free precession--initial experience.

Institutional review board approval and informed consent were obtained for this HIPAA-compliant study. In this study, iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) balanced steady-state free precession (bSSFP), fat-suppressed bSSFP, and fat-suppressed spoiled gradient-echo (GRE) sequences for 3.0-T magnetic resonance (MR) imaging of articular knee cartilage were prospectively compared in five healthy volunteers. Cartilage and fluid signal-to-noise ratio (SNR), cartilage-fluid contrast-to-noise ratio (CNR), SNR efficiency, CNR efficiency, image quality, and fat suppression were compared. Fat-suppressed bSSFP and IDEAL bSSFP had higher SNR efficiency of cartilage (P < .01) than did GRE. IDEAL bSSFP had higher cartilage-fluid CNR efficiency than did fat-suppressed bSSFP or GRE (P < .01). Fat-suppressed bSSFP and IDEAL bSSFP had higher image quality than did GRE (P < .01). GRE and IDEAL bSSFP had significantly better fat-water separation or fat saturation than did fat-suppressed bSSFP (P < .05). IDEAL bSSFP is a promising method for imaging articular knee cartilage.

Adult↗

Cardiac CINE MR imaging with a 32-channel cardiac coil and parallel imaging: impact of acceleration factors on image quality and volumetric accuracy.

PURPOSE: To assess the impact of parallel imaging algorithms on image quality and volumetric accuracy of CINE magnetic resonance imaging (MRI) with high temporal and spatial resolution using a new 32-channel dedicated cardiac phased array coil. MATERIALS AND METHODS: Fourteen individuals underwent steady-state free precession (SSFP) CINE MRI using a 32-element phased-array coil and parallel imaging acceleration using spatiotemporal sensitivity encoding (TSENSE). Acquisition acceleration ranged from R = 2 to 7. In conjunction with data extracted from phantom measurements, contrast-to-noise ratio (CNR) performance was evaluated for each acceleration factor and subjective image quality was evaluated by two independent readers. In addition, volumetric assessment was performed for each acceleration factor based on a single breath-hold multi-slice data acquisition. Results were compared to nonTSENSE measurements. RESULTS: CNR for non-accelerated CINE (R = 1) was 45.7 +/- 12.8 and showed a constant decrease with increase in acceleration of 51% at R = 4 and 86% at R = 7. CNR losses accompanied reductions in subjective image quality. Volumetric evaluation was accurate for R <or= 4, with significant underestimation of ejection fraction (EF) at higher accelerations. CONCLUSION: This study shows that one-dimensional acceleration factors up to R = 4 allow accurate SSFP CINE MRI even though CNR is significantly reduced. This allows for a marked reduction in scan time and allows for multi-slice CINE imaging with high spatial and temporal resolution.

Adult↗

T1- and T2-weighted fast spin-echo imaging of the brachial plexus and cervical spine with IDEAL water-fat separation.

PURPOSE: To compare the iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) method with fat-saturated T1-weighted (T1W) and T2W fast spin-echo (FSE) and short-TI inversion recovery (STIR) imaging of the brachial plexus and cervical spine. MATERIALS AND METHODS: Images acquired at 1.5T in five volunteers using fat-saturated T1W and T2W FSE imaging and STIR were compared with T1W and T2W IDEAL-FSE images. Examples of T1W and T2W IDEAL-FSE images acquired in patients are also shown. RESULTS: T1W and T2W IDEAL-FSE demonstrated superior fat suppression (P<0.05) and image quality (P<0.05), compared to T1W and T2W fat-saturated FSE, respectively. SNR performance of T1W-IDEAL-FSE was similar to T1W FSE in the spinal cord (P=0.250) and paraspinous muscles (P=0.78), while T2W IDEAL-FSE had superior SNR in muscle (P=0.02) and CSF (P=0.02), and marginally higher cord SNR (P=0.09). Compared to STIR, T2W IDEAL-FSE demonstrated superior image quality (P<0.05), comparable fat suppression (excellent, P=1.0), and higher SNR performance (P<0.001). CONCLUSION: IDEAL-FSE is a promising method for T1W and T2W imaging of the brachial plexus and cervical spine.

Adipose Tissue↗

Single acquisition water-fat separation: feasibility study for dynamic imaging.

Water-fat separation can be challenging in the presence of field inhomogeneities. Three-point (3-pt) water-fat separation methods achieve robust performance by measuring and compensating for field inhomogeneities; however, they triple the scan time. The "1+-pt" water-fat separation method proposed in this article for dynamic or repetitive imaging situations combines 3-pt methods' ability to correct for field inhomogeneities with the scan efficiency of a single acquisition method to achieve high temporal and spatial resolutions and robust water-fat separation. Single-echo data are collected with water and fat at a relative phase shift of an odd multiple of pi/2. To correct for undesired phase modulation, phase maps are estimated from a 3-pt calibration scan acquired prior to dynamic imaging. The phase maps are assumed to be slowly varying in time, so they may be used for correcting the phase of the subsequent single-echo signals at the same imaging location. Noise performance was investigated and shown to be equivalent to a single excitation acquisition. The 1+-pt method can also be used in conjunction with parallel imaging. In this situation, the calibration scans required by both methods can be integrated into a shared calibration scan. Promising results were obtained in breast, abdominal, and cardiac imaging applications.

Abdomen↗

Cardiac steady-state free precession CINE magnetic resonance imaging at 3.0 tesla: impact of parallel imaging acceleration on volumetric accuracy and signal parameters.

OBJECTIVES: We sought to evaluate the impact of 3.0 T on accelerated CINE steady-state free precession (SSFP) regarding signal parameters and its volumetric accuracy. MATERIAL AND METHODS: Ten individuals underwent cardiac CINE imaging at 1.5 T and 3.0 T using standard single-slice CINE and multislice TSENSE-accelerated CINE (5 slices/breath-hold) with 4-fold acceleration. Data were evaluated for left ventricular volumetric parameters (EDV, ESV, and EF) as well as for SNR and CNR. Phantom based data allowed for g-factor evaluation for estimation of noise levels for accelerated data sets. Volumetric results and signal parameters were compared with results of single-slice CINE SSFP at 1.5 T as standard of reference (SOR). RESULTS: Single-slice CINE at 3.0 T showed a approximately 90% increase in CNR compared with the SOR (P < 0.001). At 3.0 T, TSENSE CINE showed a less pronounced estimated loss in CNR (-58 +/- 6%) compared with single-slice CINE than at 1.5 T (-71 +/- 2%). 3.0 T TSENSE CINE showed a 21 +/- 18% lower CNR than the nonaccelerated 1.5 T CINE (P < 0.05). EF results for all data sets did not show any significant error while for EDV some errors have been encountered. CONCLUSION: 3.0 T permits compensation for the high CNR loss, which accompanies the 4-fold TSENSE acceleration at 1.5 T and shows volumetric accuracy. The use of parallel imaging may help to alleviate SAR limitations at higher field strength.

Adult↗

Phase-sensitive inversion recovery (PSIR) single-shot TrueFISP for assessment of myocardial infarction at 3 tesla.

PURPOSE: The aim of the current study was to show if contrast-to-noise ratio (CNR) could be improved without loss of diagnostic accuracy if a phase-sensitive inversion recovery (PSIR) single-shot TrueFISP sequence is used at 3.0 T instead of 1.5 T. MATERIAL AND METHODS: Ten patients with myocardial infarction were examined on a 1.5 T magnetic resonance (MR) system (Avanto, Siemens Medical Systems) and at a 3.0 T MR system. Imaging delayed contrast enhancement was started 10 minutes after application of contrast material. A phase-sensitive inversion recovery (PSIR) single-shot TrueFISP sequence was used at 1.5 and 3.0 T and compared with a segmented IR turboFLASH sequence at 1.5 T, which served as the reference method. Infarct volumes and CNR of infarction and normal myocardium were compared with the reference method. RESULTS: The PSIR Single-Shot TrueFISP technique allows for imaging nine slices during a single breathhold without adaptation of the inversion time. The mean value of CNR between infarction and normal myocardium was 5.9 at 1.5 T and 12.2 at 3.0 T (magnitude images). The CNR mean value of the reference method was 8.4. The CNR mean value at 3.0 T was significantly (P = 0.03) higher than the mean value of the reference method. The correlation coefficients of the infarct volumes, determined with the PSIR single-shot TrueFISP technique at 1.5 T and at 3.0 T and compared with the reference method, were r = 0.96 (P = 0.001) and r = 0.99 (P = 0.0001). CONCLUSION: The use of PSIR single-shot TrueFISP at 3.0 T allows for accurate detection and assessment of myocardial infarction. CNR is significantly higher at 3.0 T compared with 1.5 T. The PSIR single-shot technique at 3.0 T provides a higher CNR than the segmented reference technique at 1.5 T.

Adult↗

Cardiac CINE imaging with IDEAL water-fat separation and steady-state free precession.

PURPOSE: To decompose multicoil CINE steady-state free precession (SSFP) cardiac images acquired at short echo time (TE) increments into separate water and fat images, using an iterative least-squares "Dixon" (IDEAL) method. MATERIALS AND METHODS: Multicoil CINE IDEAL-SSFP cardiac imaging was performed in three volunteers and 15 patients at 1.5 T. RESULTS: Measurements of signal-to-noise ratio (SNR) matched theoretical expectations and were used to optimize acquisition parameters. TE increments of 0.9-1.0 msec permitted the use of repetition times (TRs) of 5 msec or less, and provided good SNR performance of the water-fat decomposition, while maintaining good image quality with a minimum of banding artifacts. Images from all studies were evaluated for fat separation and image quality by two experienced radiologists. Uniform fat separation and diagnostic image quality was achieved in all images from all studies. Examples from volunteers and patients are shown. CONCLUSION: Multicoil IDEAL-SSFP imaging can produce high quality CINE cardiac images with uniform water-fat separation, insensitive to Bo inhomogeneities. This approach provides a new method for reliable fat-suppression in cardiac imaging.

Adult↗

Homodyne reconstruction and IDEAL water-fat decomposition.

Multipoint water-fat separation methods have received renewed interest because they provide uniform separation of water and fat despite the presence of B0 and B1 field inhomogeneities. Unfortunately, full-resolution reconstruction of partial k-space acquisitions has been incompatible with these methods. Conventional homodyne reconstruction and related algorithms are commonly used to reconstruct partial k-space data sets by exploiting the Hermitian symmetry of k-space in order to maximize the spatial resolution of the image. In doing so, however, all phase information of the image is lost. The phase information of complex source images used in a water-fat separation acquisition is necessary to decompose water from fat. In this work, homodyne imaging is combined with the IDEAL (iterative decomposition of water and fat with echo asymmetry and least squares estimation) method to reconstruct full resolution water and fat images free of blurring. This method is extended to multicoil steady-state free precession and fast spin-echo applications and examples are shown.

Adipose Tissue↗

Cramér-Rao bounds for three-point decomposition of water and fat.

The noise analysis for three-point decomposition of water and fat was extended to account for the uncertainty in the field map. This generalization leads to a nonlinear estimation problem. The Crámer-Rao bound (CRB) was used to study the variance of the estimates of the magnitude, phase, and field map by computing the maximum effective number of signals averaged (NSA) for any choice of echo time shifts. The analysis shows that the noise properties of the reconstructed magnitude, phase, and field map depend not only on the choice of echo time shifts but also on the amount of fat and water in each voxel and their alignment at the echo. The choice of echo time shifts for spin-echo, spoiled gradient echo, and steady-state free precession imaging techniques were optimized using the CRB. The noise analysis for the magnitude explains rough interfaces seen clinically in the boundary of fat and water with source images obtained symmetrically about the spin-echo. It also provides a solution by choosing appropriate echo time shifts (-pi/6+pik, pi/2+pik, 7pi/6+pik), with k an integer. With this choice of echo time shifts it is possible to achieve the maximum NSA uniformly across all fat:water ratios. The optimization is also carried out for the estimation of phase and field map. These theoretical results were verified using Monte Carlo simulations with a newly developed nonlinear least-squares reconstruction algorithm that achieves the CRB.

Adipose Tissue↗

Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): application with fast spin-echo imaging.

Chemical shift based methods are often used to achieve uniform water-fat separation that is insensitive to Bo inhomogeneities. Many spin-echo (SE) or fast SE (FSE) approaches acquire three echoes shifted symmetrically about the SE, creating time-dependent phase shifts caused by water-fat chemical shift. This work demonstrates that symmetrically acquired echoes cause artifacts that degrade image quality. According to theory, the noise performance of any water-fat separation method is dependent on the proportion of water and fat within a voxel, and the position of echoes relative to the SE. To address this problem, we propose a method termed "iterative decomposition of water and fat with echo asymmetric and least-squares estimation" (IDEAL). This technique combines asymmetrically acquired echoes with an iterative least-squares decomposition algorithm to maximize noise performance. Theoretical calculations predict that the optimal echo combination occurs when the relative phase of the echoes is separated by 2pi/3, with the middle echo centered at pi/2+pik (k=any integer), i.e., (-pi/6+pik, pi/2+pik, 7pi/6+pik). Only with these echo combinations can noise performance reach the maximum possible and be independent of the proportion of water and fat. Close agreement between theoretical and experimental results obtained from an oil-water phantom was observed, demonstrating that the iterative least-squares decomposition method is an efficient estimator.

Adipose Tissue↗

Practical approaches to the evaluation of signal-to-noise ratio performance with parallel imaging: application with cardiac imaging and a 32-channel cardiac coil.

In this work, two practical methods for the measurement of signal-to-noise-ratio (SNR) performance in parallel imaging are described. Phantoms and human studies were performed with a 32-channel cardiac coil in the context of ultrafast cardiac CINE imaging at 1.5 T using steady-state free precession (SSFP) and TSENSE. SNR and g-factor phantom measurements using a "multiple acquisition" method were compared to measurements from a "difference method". Excellent agreement was seen between the two methods, and the g-factor shows qualitative agreement with theoretical predictions from the literature. Examples of high temporal (42.6 ms) and spatial (2.1x2.1x8 mm3) resolution cardiac CINE SSFP images acquired from human volunteers using TSENSE are shown for acceleration factors up to 7. Image quality agrees qualitatively with phantom SNR measurements, suggesting an optimum acceleration of 4. With this acceleration, a cardiac function study consisting of 6 image planes (3 short-axis views, 3 long-axis views) was obtained in an 18-heartbeat breath-hold.

Female↗

Field map estimation with a region growing scheme for iterative 3-point water-fat decomposition.

Robust fat suppression techniques are required for many clinical applications. Multi-echo water-fat separation methods are relatively insensitive to B(0) field inhomogeneity compared to the fat saturation method. Estimation of this field inhomogeneity, or field map, is an essential and important step, which is well known to have ambiguity. For an iterative water-fat decomposition method recently proposed, ambiguities still exist, but are more complex in nature. They were studied by analytical expressions and simulations. To avoid convergence to incorrect field map solutions, an initial guess closer to the true field map is necessary. This can be achieved using a region growing process, which correlates the estimation among neighboring pixels. Further improvement in stability is achieved using a low-resolution reconstruction to guide the selection of the starting pixels for the region growing. The proposed method was implemented and shown to significantly improve the algorithm's immunity to field inhomogeneity.

Adipose Tissue↗

Controversies in protocol selection in the imaging of articular cartilage.

Magnetic resonance (MR) imaging, with its unique ability to noninvasively image and characterize soft tissue, has shown promise in assessment of cartilage. The development of new, fast imaging methods with high contrast will improve the MR evaluation of cartilage morphology. In addition to morphological MR imaging methods, MR imaging contrast mechanisms under development may reveal detailed information regarding the physiology of cartilage. However, many of these methods remain to be tested in the clinical setting. Protocol selection for cartilage imaging requires understanding of the patient population and the advantages and limitations of these techniques.

Cartilage Diseases↗

Multicoil Dixon chemical species separation with an iterative least-squares estimation method.

This work describes a new approach to multipoint Dixon fat-water separation that is amenable to pulse sequences that require short echo time (TE) increments, such as steady-state free precession (SSFP) and fast spin-echo (FSE) imaging. Using an iterative linear least-squares method that decomposes water and fat images from source images acquired at short TE increments, images with a high signal-to-noise ratio (SNR) and uniform separation of water and fat are obtained. This algorithm extends to multicoil reconstruction with minimal additional complexity. Examples of single- and multicoil fat-water decompositions are shown from source images acquired at both 1.5T and 3.0T. Examples in the knee, ankle, pelvis, abdomen, and heart are shown, using FSE, SSFP, and spoiled gradient-echo (SPGR) pulse sequences. The algorithm was applied to systems with multiple chemical species, and an example of water-fat-silicone separation is shown. An analysis of the noise performance of this method is described, and methods to improve noise performance through multicoil acquisition and field map smoothing are discussed.

Adipose Tissue↗

Signal-to-noise ratio behavior of steady-state free precession.

Steady-state free precession (SSFP) is a rapid gradient-echo imaging technique that has recently gained popularity and is used in a variety of applications, including cardiac and real-time imaging, because of its high signal and favorable contrast between blood and myocardium. The purpose of this work was to examine the signal-to-noise ratio (SNR) behavior of images acquired with SSFP, and the dependence of SNR on imaging parameters such as TR, bandwidth, and image resolution, and the use of multi-echo sequences. In this work it is shown that the SNR of SSFP sequences is dependent only on pulse sequence efficiency, voxel dimensions, and relaxation parameters (T1 and T2). Notably, SNR is insensitive to bandwidth unless increases in bandwidth significantly decrease efficiency. Finally, we examined the relationship between pulse sequence performance (TR and efficiency) and gradient performance (maximum gradient strength and slew rate) for several imaging scenarios, including multi-echo sequences, to determine the optimum matching of maximum gradient strength and slew rate for gradient hardware designs. For standard modern gradient hardware (40 mT/m and 150 mT/m/ms), we found that the maximum gradient strength is more than adequate for the imaging resolution that is commonly encountered with rapid scouting (3 mm x 4 mm x 10 mm voxel). It is well matched for typical CINE and real-time cardiac imaging applications (1.5 mm x 2 mm x 6 mm voxel), and is inadequate for optimal matching with slew rate for high-resolution applications such as musculoskeletal imaging (0.5 x 0.8 x 3 mm voxel). For the lower-resolution methods, efficiency could be improved with higher slew rates; this provokes interest in designing methods for limiting dB/dt peripherally while achieving high switching rates in the imaging field of view. The use of multi-echo SSFP acquisitions leads to substantial improvements in sequence performance (i.e., increased efficiency and shorter TR).

Artifacts↗

Steady-state free precession MR imaging: improved myocardial tag persistence and signal-to-noise ratio for analysis of myocardial motion.

Tagging with balanced steady-state free-precession (SSFP) magnetic resonance (MR) imaging by using a steady-state storage scheme for myocardial motion analysis was evaluated. Signal-to-noise ratio (SNR), blood-tissue contrast, and tag persistence in volunteers and phantoms showed improved performance of SSFP imaging with tagging compared with that of radiofrequency spoiled gradient-echo (SPGR) MR imaging with tagging. Choice of flip angle with SSFP imaging involved a trade-off among SNR, blood-tissue contrast, and tag persistence. Increased SNR and tag persistence can be achieved simultaneously with SSFP imaging compared with SPGR tagging methods. As a result, the proposed technique may be useful for analysis of diastolic ventricular function.

Adult↗

Rapid MR imaging of articular cartilage with steady-state free precession and multipoint fat-water separation.

OBJECTIVE: To obtain high-quality high-resolution images of articular cartilage with reduced imaging time, we combined a novel technique of generalized multipoint fat-water separation with three-dimensional (3D) steady-state free precession (SSFP) imaging. SUBJECTS AND METHODS: The cartilage of 10 knees in five healthy volunteers was imaged with 3D SSFP imaging and a multipoint fat-water separation method capable of separating fat and water with short TE increments. Fat-saturated 3D spoiled gradient-echo (SPGR) images were obtained for comparison. RESULTS: High-quality images of the knee with excellent fat-water separation were obtained with 3D SSFP imaging. Total imaging time required was 58% less than that required for 3D SPGR imaging with a comparable cartilage signal-to-noise ratio and spatial resolution. Unlike 3D SPGR images, 3D SSFP images exhibited bright synovial fluid, providing a potential arthrographic effect. CONCLUSION: High-quality high-resolution images of articular cartilage with improved fat-water separation, bright synovial fluid, and markedly reduced acquisition times can be obtained with 3D SSFP imaging combined with a fat-water separation technique.

Adult↗