PubMed Health⌕ Search

Biomedical subjects

Scott R Paulsen

Publications and source records attributed to Scott R Paulsen.

2 recordsLinked to original sources

Polyp measurement with CT colonography: multiple-reader, multiple-workstation comparison.

OBJECTIVE: The risk of invasive colorectal cancer in colorectal polyps correlates with lesion size. Our purpose was to define the most accurate methods for measuring polyp size at CT colonography (CTC) using three models of workstations and multiple observers. MATERIALS AND METHODS: Six reviewers measured 24 unique polyps of known size (5, 7, 10, and 12 mm), shape (sessile, flat, and pedunculated), and location (straight or curved bowel segment) using CTC data sets obtained at two doses (5 mAs and 65 mAs) and a previously described colonic phantom model. Reviewers measured the largest diameter of polyps on three proprietary workstations. Each polyp was measured with lung and soft-tissue windows on axial, 2D multiplanar reconstruction (MPR), and 3D images. RESULTS: There were significant differences among measurements obtained at various settings within each workstation (p < 0.0001). Measurements on 2D images were more accurate with lung window than with soft-tissue window settings (p < 0.0001). For the 65-mAs data set, the most accurate measurements were obtained in analysis of axial images with lung window, 2D MPR images with lung window, and 3D tissue cube images for Wizard, Advantage, and Vitrea workstations, respectively, without significant differences in accuracy among techniques (0.11 < p < 0.59). The mean absolute error values for these optimal settings were 0.48 mm, 0.61 mm, and 0.76 mm, respectively, for the three workstations. Within the ultralow-dose 5-mAs data set the best methods for Wizard, Advantage, and Vitrea were axial with lung window, 2D MPR with lung window, and 2D MPR with lung window, respectively. Use of nearly all measurement methods, except for the Vitrea 3D tissue cube and the Wizard 2D MPR with lung window, resulted in undermeasurement of the true size of the polyps. CONCLUSION: Use of CTC computer workstations facilitates accurate polyp measurement. For routine CTC examinations, polyps should be measured with lung window settings on 2D axial or MPR images (Wizard and Advantage) or 3D images (Vitrea). When these optimal methods are used, these three commercial workstations do not differ significantly in acquisition of accurate polyp measurements at routine dose settings.

Algorithms↗

CT enterography as a diagnostic tool in evaluating small bowel disorders: review of clinical experience with over 700 cases.

Computed tomographic (CT) enterography combines the improved spatial and temporal resolution of multi-detector row CT with large volumes of ingested neutral enteric contrast material to permit visualization of the small bowel wall and lumen. Adequate luminal distention can usually be achieved with oral hyperhydration, thereby obviating nasoenteric intubation and making CT enterography a useful, well-tolerated study for the evaluation of diseases affecting the mucosa and bowel wall. Unlike routine CT, which has been used to detect the extraenteric complications of Crohn disease such as fistula and abscess, CT enterography clearly depicts the small bowel inflammation associated with Crohn disease by displaying mural hyperenhancement, stratification, and thickening; engorged vasa recta; and perienteric inflammatory changes. As a result, CT enterography is becoming the first-line modality for the evaluation of suspected inflammatory bowel disease. CT enterography has also become an important alternative to traditional fluoroscopy in the assessment of other small bowel disorders such as celiac sprue and small bowel neoplasms.

Contrast Media↗