Roll rotation cues influence roll tilt perception assayed using a somatosensory technique.

We investigated how the nervous system processes ambiguous cues from the otolith organs by measuring roll tilt perception elicited by two motion paradigms. In one paradigm (tilt), eight subjects were sinusoidally tilted in roll with the axis of rotation near ear level. Stimulus frequencies ranged from 0.005 to 0.7 Hz, and the peak amplitude of tilt was 20 degrees . During this paradigm, subjects experienced a sinusoidal variation of interaural gravitational force with a peak of 0.34 g. The second motion paradigm (translation) was designed to yield the same sinusoidal variation in interaural force but did not include a roll canal cue. This was achieved by sinusoidally translating the subjects along their interaural axis. For the 0.7-Hz translation trial, the subjects were simply translated from side to side. A centrifuge was used for the 0.005- to 0.5-Hz translation trials; the subjects were rotated in yaw at 250 degrees /s for 5 min before initiating sinusoidal translations yielding an interaural otolith stimulus composed of both centrifugal and radial acceleration. Using a somatosensory task to measure roll tilt perception, we found substantial differences in tilt perception during the two motion paradigms. Because the primary difference between the two motion paradigms was the presence of roll canal cues during roll tilt trials, these perceptual differences suggest that canal cues influence tilt perception. Specifically, rotational cues provided by the semicircular canals help the CNS resolve ambiguous otolith cues during head tilt, yielding more accurate tilt perception.

Adult↗

Vestibular perception and action employ qualitatively different mechanisms. I. Frequency response of VOR and perceptual responses during Translation and Tilt.

To investigate the neural mechanisms that humans use to process the ambiguous force measured by the otolith organs, we measured vestibuloocular reflexes (VORs) and perceptions of tilt and translation. One primary goal was to determine if the same, or different, mechanisms contribute to vestibular perception and action. We used motion paradigms that provided identical sinusoidal inter-aural otolith cues across a broad frequency range. We accomplished this by sinusoidally tilting (20 degrees, 0.005-0.7 Hz) subjects in roll about an earth-horizontal, head-centered, rotation axis ("Tilt") or sinusoidally accelerating (3.3 m/s2, 0.005-0.7 Hz) subjects along their inter-aural axis ("Translation"). While identical inter-aural otolith cues were provided by these motion paradigms, the canal cues were substantially different because roll rotations were present during Tilt but not during Translation. We found that perception was dependent on canal cues because the reported perceptions of both roll tilt and inter-aural translation were substantially different during Translation and Tilt. These findings match internal model predictions that rotational cues from the canals influence the neural processing of otolith cues. We also found horizontal translational VORs at frequencies >0.2 Hz during both Translation and Tilt. These responses were dependent on otolith cues and match simple filtering predictions that translational VORs include contributions via simple high-pass filtering of otolith cues. More generally, these findings demonstrate that internal models govern human vestibular "perception" across a broad range of frequencies and that simple high-pass filters contribute to human horizontal translational VORs ("action") at frequencies above approximately 0.2 Hz.

Adult↗

Vestibular perception and action employ qualitatively different mechanisms. II. VOR and perceptual responses during combined Tilt&Translation.

To compare and contrast the neural mechanisms that contribute to vestibular perception and action, we measured vestibuloocular reflexes (VOR) and perceptions of tilt and translation. We took advantage of the well-known ambiguity that the otolith organs respond to both linear acceleration and tilt with respect to gravity and investigated the mechanisms by which this ambiguity is resolved. A new motion paradigm that combined roll tilt with inter-aural translation ("Tilt&Translation") was used; subjects were sinusoidally (0.8 Hz) roll tilted but with their ears above or below the rotation axis. This paradigm provided sinusoidal roll canal cues that were the same across trials while providing otolith cues that varied linearly with ear position relative to the earth-horizontal rotation axis. We found that perceived tilt and translation depended on canal cues, with substantial roll tilt and inter-aural translation perceptions reported even when the otolith organs measured no inter-aural force. These findings match internal model predictions that rotational cues from the canals influence the neural processing of otolith cues. We also found horizontal translational VORs that varied linearly with radius; a minimal response was measured when the otolith organs transduced little or no inter-aural force. Hence, the horizontal translational VOR was dependent on otolith cues but independent of canal cues. These findings match predictions that translational VORs are elicited by simple filtering of otolith signals. We conclude that internal models govern human perception of tilt and translation at 0.8 Hz and that high-pass filtering governs the human translational VOR at this same frequency.

Acceleration↗

Neurovestibular and sensorimotor studies in space and Earth benefits.

This review summarizes what has been learned from studies of human neurovestibular system in weightless conditions, including balance and locomotion, gaze control, vestibular-autonomic function and spatial orientation, and gives some examples of the potential Earth benefits of this research. Results show that when astronauts and cosmonauts return from space flight both the peripheral and central neural processes are physiologically and functionally altered. There are clear distinctions between the virtually immediate adaptive compensations to weightlessness and those that require longer periods of time to adapt. However, little is known to date about the adaptation of sensory-motor functions to long-duration space missions in weightlessness and to the transitions between various reduced gravitational levels, such as on the Moon and Mars. Results from neurovestibular research in space have substantially enhanced our understanding of the mechanisms and characteristics of postural, gaze, and spatial orientation deficits, analogous to clinical cases of labyrinthine-defective function. Also, space neurosciences research has participated in the development and application of significant new technologies, such as video recording and processing of three-dimensional eye movements and posture, hardware for the unencumbered measurement of head and body movement, and procedures for investigating otolith function on Earth. In particular, devices such as centrifugation or off-vertical axis rotation could enhance clinical neurological testing because it provides linear acceleration which specifically stimulates the otolith organs in a frequency range close to natural head and body movement.

Earth, Planet↗

Noninvasive fluid flow measurements in microfluidic channels with backscatter interferometry.

The ability to measure fluid velocity within picoliter volumes or on-chip noninvasively, is important toward fully realizing the potential of microfluidics and micrototal analysis systems, particularly in applications such as micro-high-performance liquid chromatography (HPLC) or in metering mixing where the flow rate must be quantified. Additionally, these measurements need to be performed directly on moving fluids in a noninvasive fashion. We presented here the proof of principle experiments showing nonintrusive fluid flow measurements can be accomplished on-chip using a pump and probe configuration with backscattering interferometry. The on-chip interferometric backscatter detector (OCIBD) is based on a fiber-coupled HeNe laser that illuminates a portion of an isotropically etched 40 microm radius channel and a position sensitive transducer to measure fringe pattern shifts. An infrared laser with a mechanical shutter is used to heat a section of a flowing volume and the resulting refractive index (RI) change is detected with the OCIBD downstream as a time-dependent RI perturbation. Fluid velocity is quantified as changes in the phase difference between the shutter signal and the OCIBD detected signal in the Fourier domain. The experiments are performed in the range of 3-6 microL/h with 3sigma detection limits determined to be 0.127 nL/s. Additionally, the RI response of the system is calibrated using temperature changes as well as glycerol solutions.

Equipment Design↗

Dynamic posturography in humans imagining a fixed spatial reference.

OBJECTIVE: To investigate the effect of imagining a fixed spatial reference on balance control. MATERIAL AND METHODS: Twenty-one healthy subjects were asked to remain as stable as possible while standing on a sway-referenced platform (NeuroCom Equitest posturography system). Subjects were instructed to keep their eyes open in the dark and to either look far into the distance without fixating on any particular point in space or to direct their gaze towards a remembered earth-fixed target (25-cm distant). Room lights were switched off immediately before each 20-s sway recording. Postural stability measures included equilibrium scores and root-mean-square sway amplitudes in the anterior-posterior plane. RESULTS: Postural sway was not influenced by the instruction to gaze towards a remembered target. CONCLUSION: Imagining a fixed spatial reference does not influence postural control, at least during sway-referenced dynamic posturography.

Adolescent↗