PubMed Health⌕ Search

Biomedical subjects

Sean Snow

Publications and source records attributed to Sean Snow.

2 recordsLinked to original sources

Intraspinal microstimulation using cylindrical multielectrodes.

A cylindrical multielectrode system specifically designed for intraspinal microstimulation was mechanically and electrically evaluated in the ventral horn of the feline lumbo-sacral spinal cord. Electrode insertions proved to be straight as evaluated from radiographs. Impedances were measured in situ and force recruitment curves from quadriceps muscles were collected over a wide range of stimulus parameters. For a given charge, higher current amplitudes produced greater forces than proportionally longer pulse durations, indicating that charge is not the sole indicator of evoked force in applications utilizing electrical stimulation. Overlap measurements for calculating current-distance constants were collected at a variety of current amplitudes, electrode pair separations, and pair orientations in the spinal grey matter. Forces obtained in the majority of these trials demonstrated an order effect, presumably due to asymmetric neuronal connectivity within the spinal cord. In the cases showing no order effect, the dorso-ventral electrode pair orientation yielded a higher average current-distance constant (278 microA/mm2) than either the medio-lateral or rostro-caudal electrode pair orientations (197 microA/mm2). Specifications of an array of cylindrical multielectrodes for use in future intraspinal microstimulation prostheses were updated.

Animals↗

Microfabricated cylindrical multielectrodes for neural stimulation.

The effects of spinal cord injuries are likely to be ameliorated with the help of functional electrical stimulation of the spinal cord, a technique that may benefit from a new style of electrode: the cylindrical multielectrode. This paper describes the specifications for, fabrication techniques for, and in vitro evaluation of cylindrical multielectrodes. Four tip shapes were tested to determine which shape required the lowest peak force and would, therefore, be expected to minimize dimpling during implantation. The impedance of the electrode interface was monitored for changes due to insertion as well as repetitive delivery of current pulses. The charge delivery capacity was determined by testing with safe (< or = 0.6 mC/cm2) and damaging levels (> or = 0.8 mC/cm2) of charge density. The results of these tests suggest that this electrode design could be used to stimulate neurons in the ventral horn of the spinal cord.

Animals↗