Coronary MR angiography at 3.0 T versus that at 1.5 T: initial results in patients suspected of having coronary artery disease.

PURPOSE: To prospectively evaluate the feasibility, image quality, and accuracy of coronary magnetic resonance (MR) angiography at 3.0 T in patients suspected of having coronary artery disease and to prospectively compare these results with those of coronary MR angiography performed at 1.5 T. MATERIALS AND METHODS: The study was approved by the institutional review board, and informed consent was obtained from all patients. Eighteen patients (11 men, seven women; mean age, 63 years; age range, 45-76 years) suspected of having coronary artery disease who were scheduled to undergo elective conventional coronary angiography (reference standard) were included. For coronary MR angiography at 3.0 and 1.5 T, a vector electrocardiographically gated three-dimensional segmented k-space gradient-echo imaging sequence was combined with real-time respiratory navigator gating and tracking. Signal-to-noise ratios (SNRs), contrast-to-noise ratios (CNRs), scores of image quality and sensitivity and specificity for the detection of coronary artery stenosis on a segment-by-segment basis were assessed at 3.0 and 1.5 T. Data were analyzed for statistical differences by using the Wilcoxon matched-pairs test and the McNemar test. RESULTS: The average increase in SNR at 3.0 T with respect to that at 1.5 T was 29.5% for the left coronary artery (LCA) and 31.2% for the right coronary artery (RCA) (P < .001), and the average increase in CNR was 21.8% for the LCA and 23.5% for the RCA (P < .001). Scores of image quality (P = .77) and diagnostic accuracy for the detection of coronary artery stenoses (sensitivity and specificity: 82% and 89%, respectively, at 3.0 T vs 82% and 88% at 1.5 T; P > .99) were identical or almost identical at both field strengths. CONCLUSION: Coronary MR angiography at 3.0 T is feasible in patients suspected of having coronary artery disease and yields significant increases in SNR and CNR, although current techniques do not result in significantly improved image quality and diagnostic accuracy compared with the quality and accuracy at 1.5 T. (c) RSNA, 2005.

Aged↗

Silent and apparent cerebral embolism after retrograde catheterisation of the aortic valve in valvular stenosis: a prospective, randomised study.

BACKGROUND: In most patients, severity of valvular aortic stenosis can be accurately assessed non-invasively by echocardiography. However, retrograde catheterisation of the aortic valve is often undertaken. This procedure has a potential risk of neurological complications, with an unknown incidence of clinically silent embolism. We aimed to establish the frequency of clinically apparent and silent cerebral embolism after this procedure. METHODS: We prospectively randomised 152 consecutive patients with valvular aortic stenosis at a German university hospital to receive either cardiac catheterisation with (n=101) or without (n=51) passage through the aortic valve. Patients underwent cranial MRI and neurological assessment within 48 h before and after the procedure to assess cerebral embolism. Controls were 32 patients without valvular aortic stenosis who underwent coronary angiography and laevocardiography. FINDINGS: 22 of 101 patients (22%) who underwent retrograde catheterisation of the aortic valve had focal diffusion-imaging abnormalities in a pattern consistent with acute cerebral embolic events after the procedure; three of these patients (3%) had clinically apparent neurological deficits. By contrast, none of the patients without passage of the valve, or any of the controls, had evidence of cerebral embolism as assessed by MRI. INTERPRETATION: Patients with valvular aortic stenosis who undergo retrograde catheterisation of the aortic valve have a substantial risk of clinically apparent cerebral embolism, and frequently have silent ischaemic brain lesions. Patients should be informed about these risks, and this procedure should be used only in patients with unclear echocardiographical findings when additional information is necessary for clinical management.

Aortic Valve↗

Characterization of viable and nonviable myocardium at MR imaging: comparison of gadolinium-based extracellular and blood pool contrast materials versus manganese-based contrast materials in a rat myocardial infarction model.

PURPOSE: To determine the contrast agent behavior of gadolinium-based (extracellular and albumin-binding) and manganese-based contrast media for late-enhancement imaging of myocardial infarction. MATERIALS AND METHODS: Coronary ligation was performed in 30 rats, and they were serially imaged with segmented inversion-recovery gradient-echo magnetic resonance (MR) imaging (repetition time msec/echo time msec/inversion time msec [fixed], 5.2/2.5/430; flip angle, 15 degrees ) during 1 hour after administration of contrast media by using a 1.5-T MR unit. Serial measurements of the longitudinal relaxation were performed by using the Look-Locker approach (repetition time msec/echo time msec, 1,000/3.5; flip angle, 10 degrees ). Detection and size of infarction were evaluated at each time point and compared with end-point histologic findings. RESULTS: For all manganese-based media, the contrast agent cleared from the blood pool rapidly. Manganese-based contrast media allowed precise labeling of viable cardiomyocytes within 30 minutes, and the labeling persisted for at least 1 hour. Accumulation of gadoversetamide in the infarct area was apparent after 5 minutes, and the peak contrast-to-noise ratio (CNR) between infarct and myocardium was comparable to the peak CNR of manganese-based contrast agents. Extracellular gadopentetate dimeglumine provided excellent infarct detection but a small imaging window for precise sizing of the infarct if a fixed inversion time of 430 msec was used. Albumin-binding gadolinium-based contrast media provided a longer imaging window, but infarct size was overestimated because of the nonspecific distribution of the unbound gadolinium agent. CONCLUSION: When extracellular gadolinium-based agents are used for infarct size measurement, imaging parameters and timing are important because the kinetics of both normal and irreversibly injured myocardium must be considered. Manganese-based agents are highly specific and less sensitive to timing for infarct size determination, but further studies are required to determine if they are feasible for human use.

Analysis of Variance↗

Thalamic involvement in sporadic Creutzfeldt-Jakob disease: a diffusion-weighted MR imaging study.

BACKGROUND AND PURPOSE: Recent neuropathologic research suggests thalamic involvement in sporadic Creutzfeldt-Jakob disease (sCJD), which has been disregarded in imaging studies. Diffusion-weighted (DW) MR imaging has the highest sensitivity for the detection of signal intensity (SI) abnormalities in CJD. We hypothesized that pathologic changes in the thalamus in sCJD can be detected by using a subtle analysis of DW MR imaging. METHODS: Six sCJD patients and nine healthy controls were examined with a 1.5-T system by using DW single-shot spin-echo echo planar (b = 0, 1000 s/mm(2)), T2-weighted turbo spin-echo, and fluid-attenuated inversion recovery sequences. One patient was examined serially (3, 4, and 8 months after onset of symptoms). MR images were reviewed for SI changes in the striatum, hippocampus, mediodorsal thalamic nucleus (MD), and pulvinar thalami. Apparent diffusion coefficients (ADCs) were measured in these areas. RESULTS: All sCJD patients showed increased SI on DW images in the striatum bilaterally. ADCs in these areas were significantly reduced. Four of six sCJD patients showed increased SI on DW images in the pulvinar thalami, whereas ADCs were significantly reduced in all patients (mean ADC +/- SEM: in patients with SI changes, 701 +/- 38; in patients without SI changes, 684 +/- 37; in controls, 853 +/- 15 [P <.0001]). No patient showed SI changes in the MD on DW images, whereas ADCs were significantly reduced in all (664 +/- 28 as compared with 800 +/- 24 in controls [P =.0011]). Serial measurements in one sCJD patient showed ADC reduction in the pulvinar thalami preceding the SI changes on DW images. CONCLUSION: A quantitative analysis of DW images with ADC measurements shows slight MR imaging changes in the thalamus in sCJD when abnormal SI may not be present.

Aged↗

Regional N-acetylaspartate reduction in the hippocampus detected with fast proton magnetic resonance spectroscopic imaging in patients with Alzheimer disease.

OBJECTIVE: To detect regional metabolic changes that resemble the expected spatial pattern of neuronal loss in patients with Alzheimer disease (AD). METHODS: Thirty-four patients with AD and 22 healthy control subjects were included in the study. Single-slice fast proton spectroscopic imaging was performed in parallel angulation to the temporal lobes. Proton spectra were selected from the hippocampus, the lateral temporal lobe, and the occipital lobe of both hemispheres to determine metabolite concentration of N-acetylaspartate (NAA), total creatine (tCr), including phosphocreatine and creatine, and choline-containing compounds (Cho). The metabolic ratios of NAA/tCr and Cho/tCr were calculated and compared between patients with AD and healthy volunteers. RESULTS: The NAA/tCr ratios were significantly reduced in the left (F(1,1) = 4.34, P =.04) and right hippocampus (F(1,1) = 9.96, P =.003) in patients with AD. The Cho/tCr ratios remained unchanged in both hippocampi. There was no significant change of either NAA/tCr or Cho/tCr in the lateral temporal and occipital lobes of patients with AD. CONCLUSION: This study provides evidence that fast proton spectroscopic imaging may detect the regional pattern of disturbed neuronal integrity in patients with AD with high spatial resolution in a short acquisition time.

Aged↗

Evaluation of a new ultrasmall superparamagnetic iron oxide contrast agent Clariscan, (NC100150) for MRI of renal perfusion: experimental study in an animal model.

PURPOSE: To determine the diagnostic value of a new ultrasmall superparamagnetic iron oxide Clariscan, (NC100150) for the evaluation of renal perfusion in an animal model using a 3D-FFE-EPI sequence. MATERIALS AND METHODS: Four groups of four rabbits each were imaged after bolus injection of NC100150, using a 1.5 T MR system (Gyroscan ACS-NT). T2*w MR images in the coronal plane were acquired over 60 seconds with an echo-shifted 3D-FFE-EPI sequence (TR/TE/alpha = 18/25 msec/8 degrees ). Data were transferred to a workstation and converted into concentration curves. Based on the fitted concentration time curves, parameter maps were calculated pixelwise: bolus arrival time (T0), time-to-peak (TTP), mean transit time (MTT), and relative bolus volume (rBV). Maximum signal decrease was determined with respect to the baseline value. RESULTS: Mean MTT increased from 4.2 seconds at a dose of 0.25 mg to 5.9 seconds at 1.0 mg (P < .0001). The maximum signal decrease was observed at 0.75 mg, corresponding to 85% of the baseline value. Transit times of the contrast bolus were accurately calculated for the cortex and the outer medulla, but at the level of the inner medulla no arterial flow profile was identified. No significant difference between the cortex and the outer medulla was found for either T0 or rBV, but medullar TTP and MTT were prolonged with regard to cortical TTP and MTT (6.3 seconds vs. 5.7 seconds, P < .001; 5.7 seconds vs. 4.2 seconds, P < .0001). CONCLUSION: The employed intravascular contrast agent is well suited to assess renal perfusion. By the use of a T2*w3D perfusion sequence, cortical and medullar transit times can be quantified and physiologic information on regional perfusion differences can be obtained.

Animals↗

Hepatocellular carcinoma: detection with gadolinium- and ferumoxides-enhanced MR imaging of the liver.

PURPOSE: To test the hypothesis that the accuracy of gadolinium- and ferumoxides-enhanced magnetic resonance (MR) imaging is different in small (< or =1.5-cm) and large (>1.5-cm) hepatocellular carcinomas (HCCs). MATERIALS AND METHODS: Forty-three consecutive patients with chronic liver disease were enrolled in this study. The imaging protocol included unenhanced breath-hold T1-weighted fast field-echo sequences, unenhanced respiratory-triggered T2-weighted turbo spin-echo (SE) sequences, dynamic gadolinium-enhanced T1-weighted three-dimensional turbo field-echo sequences, and ferumoxides-enhanced T2-weighted turbo SE sequences. Images of each sequence and two sets of sequences (ferumoxides set and gadolinium set) were reviewed by four observers. The ferumoxides set included unenhanced T1- and T2-weighted images and ferumoxides-enhanced T2-weighted turbo SE MR images. The gadolinium set included unenhanced T1- and T2-weighted images and dynamic gadolinium-enhanced three-dimensional turbo field-echo MR images. In receiver operating characteristic (ROC) curve analysis, the sensitivity and accuracy of the sequences were compared in regard to the detection of all, small, and large HCCs. RESULTS: Imaging performance was different with gadolinium- and ferumoxides-enhanced images in the detection of small and large HCCs. For detection of small HCCs, the sensitivity and accuracy with unenhanced and gadolinium-enhanced imaging (gadolinium set) were significantly (P =.017) superior to those with unenhanced and ferumoxides-enhanced imaging (ferumoxides set). The area under the composite ROC curves, or A(z), for the gadolinium set and the ferumoxides set was 0.97 and 0.81, respectively. For large HCC, the ferumoxides set was superior compared with the gadolinium set, but this difference was not statistically significant. Analysis of all HCCs demonstrated no significant differences for gadolinium- and ferumoxides-enhanced imaging. CONCLUSION: For the detection of early HCC, gadolinium-enhanced MR imaging is preferred to ferumoxides-enhanced MR imaging because the former demonstrated significantly greater accuracy in the detection of small HCCs.

Adult↗

Abdomen: diffusion-weighted MR imaging with pulse-triggered single-shot sequences.

Magnetic resonance (MR) diffusion measurements of the abdomen were performed in 12 healthy volunteers by using a diffusion-weighted single-shot sequence both without and with pulse triggering for different trigger delays. Pulse triggering to the diastolic heart phase led to reduced motion artifacts on the diffusion-weighted MR images and to significantly improved accuracy and reproducibility of measurements of the apparent diffusion coefficients, or ADCs, of abdominal organs.

Abdomen↗