PubMed Health⌕ Search

Biomedical subjects

Sebastian Ley

Publications and source records attributed to Sebastian Ley.

At least 19 recordsLinked to original sources

Value of MR phase-contrast flow measurements for functional assessment of pulmonary arterial hypertension.

Goals of our study were to compare the pulmonary hemodynamics between healthy volunteers and patients with pulmonary arterial hypertension (PAH) and correlate MR flow measurements with echocardiography. Twenty-five patients with PAH and 25 volunteers were examined at 1.5 T. Phase-contrast flow measurements were performed in the ascending aorta and pulmonary trunk, resulting in the following parameters: peak velocity (cm/s), average blood flow (l/min), time to peak velocity (ms), velocity rise gradient and pulmonary distensibility (cm(2)). The bronchosystemic shunt was calculated. In PAH patients transthoracic echocardiography and right-heart catheterization (RHC) served as the gold standard. In comparison to volunteers, the PAH patients showed significantly reduced pulmonary velocities (P = 0.002), blood flow (P = 0.002) and pulmonary distensibility (P = 0.008). In patients, the time to peak velocity was shorter (P<0.001), and the velocity rise gradient was steeper (P = 0.002) than in volunteers. While in volunteers the peak velocity in the aorta was reached earlier, it was the reverse in patients. Patients showed a significant bronchosystemic shunt (P = 0.01). No meaningful correlation was found between MRI measurements and echocardiography or RHC. MRI is a feasible technique for the differentiation between PAH and volunteers. Further studies have to be conducted for the absolute calculation of pressure estimates.

Adult↗

Quantitative 3D pulmonary MR-perfusion in patients with pulmonary arterial hypertension: correlation with invasive pressure measurements.

PURPOSE: Pathological changes of the peripheral pulmonary arteries induce pulmonary arterial hypertension (PAH). Aim of this study was to quantitatively assess the effect of PAH on pulmonary perfusion by 3D-MR-perfusion techniques and to compare findings to healthy controls. Furthermore, quantitative perfusion data were correlated with invasive pressure measurements. MATERIAL AND METHODS: Five volunteers and 20 PAH patients (WHO class II or III) were examined using a 1.5T MR scanner. Measurement of pulmonary perfusion was done in an inspiratory breathhold (FLASH3D; 3.5 mm x 1.9 mm x 4mm; TA per 3D dataset 1.5s). Injection of contrast media (0.1 mmol Gd-DTPA/kg BW) and image acquisition were started simultaneously. Evaluation of 3D perfusion was done using singular value decomposition. Lung borders were outlined manually. Each lung volume was divided into three regions (anterior, middle, posterior), and the following parameters were assessed: Time-to-Peak (TTP), blood flow (PBF), blood volume (PBV), and mean transit time (MTT). In 10 patients invasive pulmonary artery pressure measurements were available and correlated to the perfusion measurements. RESULTS: In both, controls and patients, an anterior-to-posterior gradient with higher PBF and PBV posterior was observed. In the posterior lung region, a significant difference (p<0.05) was found for TTP (12s versus 16s) and MTT (4s versus 6s) between volunteers and patients. PBF and PBV were lower in patients than in volunteers (i.e. dorsal regions: 124 versus 180 ml/100 ml/min and 10 versus 12 ml/100 ml), but the difference failed to be significant. The ratio of PBF and PBV between the posterior and the middle or ventral regions showed no difference between both groups. A moderate linear correlation between mean pulmonary arterial pressure (mPAP) and PBV (r=0.51) and MTT (r=0.56) was found. CONCLUSION: The only measurable effect of PAH on pulmonary perfusion is a prolonging of the MTT. There is only a moderate linear correlation of invasive mPAP with PBV and MTT.

Adult↗

MR flow measurements for assessment of the pulmonary, systemic and bronchosystemic circulation: impact of different ECG gating methods and breathing schema.

PURPOSE: Different ECG gating techniques are available for MR phase-contrast (PC) flow measurements. Until now no study has reported the impact of different ECG gating techniques on quantitative flow parameters. The goal was to evaluate the impact of the gating method and the breathing schema on the pulmonary, systemic and bronchosystemic circulation. MATERIAL AND METHODS: Twenty volunteers were examined (1.5 T) with free breathing phase-contrast flow (PC-flow) measurements with prospective (free-prospective) and retrospective (free-retrospective) ECG gating. Additionally, expiratory breath-hold retrospective ECG gated measurements (bh-retrospective) were performed. Blood flow per minute; peak velocity and time to peak velocity were compared. The clinically important difference between the systemic and pulmonary circulation (bronchosystemic shunt) was calculated. RESULTS: Blood flow per minute was lowest for free-prospective (6 l/min, pulmonary trunc) and highest for bh-retrospective measurements (6.9 l/min, pulmonary trunc). No clinically significant difference in peak velocity was assessed (82-83 cm/s pulmonary trunc, 109-113 cm/s aorta). Time to peak velocity was shorter for retro-gated free-retrospective and bh-retrospective than for pro-gated free-prospective. The difference between systemic and pulmonary measurements was least for the free-retrospective technique. CONCLUSION: The type of gating has a significant impact on flow measurements. Therefore, it is important to use the same ECG gating method, especially for follow-up examinations. Retrospective ECG gated free breathing measurements allow for the most precise assessment of the bronchosystemic blood flow and should be used in clinical routine.

Adult↗

Magnetic resonance imaging of uneven pulmonary perfusion in hypoxia in humans.

RATIONALE: Inhomogeneous hypoxic pulmonary vasoconstriction causing regional overperfusion and high capillary pressure is postulated for explaining how high pulmonary artery pressure leads to high-altitude pulmonary edema in susceptible (HAPE-S) individuals. OBJECTIVE: Because different species of animals also show inhomogeneous hypoxic pulmonary vasoconstriction, we hypothesized that inhomogeneity of lung perfusion in general increases in hypoxia, but is more pronounced in HAPE-S. For best temporal and spatial resolution, regional pulmonary perfusion was assessed by dynamic contrast-enhanced magnetic resonance imaging. METHODS: Dynamic contrast-enhanced magnetic resonance imaging and echocardiography were performed during normoxia and after 2 h of hypoxia (Fi(O2) = 0.12) in 11 HAPE-S individuals and 10 control subjects. As a measure for perfusion inhomogeneity, the coefficient of variation for two perfusion parameters (peak signal intensity, time-to-peak) was determined for the whole lung and isogravitational slices. RESULTS: There were no differences in perfusion inhomogeneity between the groups in normoxia. In hypoxia, analysis of coefficients of variation indicated a greater inhomogeneity in all subjects, which was more pronounced in HAPE-S compared with control subjects. Discrimination between HAPE-S and control subjects was best in gravity-dependent lung areas. Pulmonary artery pressure during hypoxia increased from 22 +/- 3 to 53 +/- 9 mm Hg in HAPE-S and 24 +/- 4 to 33 +/- 6 mm Hg in control subjects (mean +/- SD; p < 0.001), respectively. CONCLUSION: This study shows that hypoxic pulmonary vasoconstriction is inhomogeneous in hypoxia in humans, particularly in HAPE-S individuals where it is accompanied by a greater increase in pulmonary artery pressure compared with control subjects. These findings support the hypothesis of exaggerated and uneven hypoxic pulmonary vasoconstriction in HAPE-S individuals.

Adult↗

Proton MRI appearance of cystic fibrosis: comparison to CT.

Cystic fibrosis (CF) is the most frequent inherited disorder leading to premature death in the Caucasian population. As life expectancy is limited by pulmonary complications, repeated imaging [chest X-ray, multislice high-resolution computed tomography (MS-HRCT)] is required in the follow-up. Magnetic resonance imaging (MRI) of the lung parenchyma is a promising new diagnostic tool. Its value for imaging lung changes caused by CF compared with CT is demonstrated. MRI performs well when compared with CT, which serves as the gold standard. Its lack in spatial resolution is obvious, but advantages in contrast and functional assessment compensate for this limitation. Thus, MRI is a reasonable alternative for imaging the CF lung and should be introduced as a radiation-free modality for follow-up studies in CF patients. For further evaluation of the impact of MRI, systematic studies comparing MRI and conventional imaging modalities are necessary. Furthermore, the value of the additional functional MRI (fMRI) information has to be studied, and a scoring system for the morphological and functional aspect of MRI has to be established.

Adolescent↗

Visualization of intrarenal vessels by 3.0-T MR angiography in comparison with digital subtraction angiography using renal specimens.

BACKGROUND: MRI at 3.0 T enables high-spatial resolution for renal MR angiography. OBJECTIVE: Evaluation of an arterial tree model in animal kidney specimens with comparison of digital subtraction angiography (DSA) and high-field MRI to find out the maximum spatial resolution of intrarenal vessels. It was considered that objective quantitation of angiogram quality could be achieved. MATERIALS AND METHODS: A total of 27 pig kidney specimens were examined by MR angiography (flash 3D) using a 3.0-T scanner (TRIO; Siemens, Erlangen, Germany) with an eight-channel head coil and a voxel size of 0.9x0.9x1.1 mm in the early arterial phase after implantation of a 4F catheter in the renal artery. DSA (Integris, Philips, Best, The Netherlands) was performed immediately after the MRI. With the help of semiautomated segmentation, all vessels were marked for comparison of the vessel trees. The Wilcoxon rank test was used for statistical evaluation of vessel numbers and branching depths. RESULTS: Objective comparison between DSA and MR angiography was achieved. High-field MR angiography had the ability to depict vessels up to the seventh branching on average. Significant differences in vessel delineation and counts were found from the fifth level of intrarenal branching onwards with DSA showing an advantage. CONCLUSION: High-field MRI has great potential in the detection of intrarenal arteries and is comparable to DSA in visualization of the central intrarenal vessel tree.

Angiography, Digital Subtraction↗

Chronic thromboembolic pulmonary hypertension - assessment by magnetic resonance imaging.

Chronic thromboembolic pulmonary hypertension (CTEPH) is a severe disease that has been ignored for a long time. However, with the development of improved therapeutic modalities, cardiologists and thoracic surgeons have shown increasing interest in the diagnostic work-up of this entity. The diagnosis and management of chronic thromboembolic pulmonary hypertension require a multidisciplinary approach involving the specialties of pulmonary medicine, cardiology, radiology, anesthesiology and thoracic surgery. With this approach, pulmonary endarterectomy (PEA) can be performed with an acceptable mortality rate. This review article describes the developments in magnetic resonance (MR) imaging techniques for the diagnosis of chronic thromboembolic pulmonary hypertension. Techniques include contrast-enhanced MR angiography (ce-MRA), MR perfusion imaging, phase-contrast imaging of the great vessels, cine imaging of the heart and combined perfusion-ventilation MR imaging with hyperpolarized noble gases. It is anticipated that MR imaging will play a central role in the initial diagnosis and follow-up of patients with CTEPH.

Chronic Disease↗

Preoperative assessment and follow-up of congenital abnormalities of the pulmonary arteries using CT and MRI.

Congenital heart disease (CHD), including complex anomalies of the pulmonary arteries, are now earlier diagnosed and treated. Due to improvements in interventional and surgical therapy, the number of patients with the need for follow-up examinations is increasing. Pre- and postinterventional imaging should be done as gently as possible, avoiding invasive techniques if possible. With the technical improvement of multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI), both techniques are increasingly used for noninvasive assessment of the pulmonary vasculature in children with CHD. Knowledge of the most common diseases affecting the pulmonary vasculature and the kind of surgical and interventional procedures is essential for optimal imaging planning. This is especially important because interventions can be positively influenced by high-quality imaging. Therefore, the most common diseases and procedures are described and imaging modality of choice and important image findings are discussed.

Adolescent↗

Contrast-enhanced 3D MRI of lung perfusion in children with cystic fibrosis--initial results.

This paper is a feasibility study of magnetic resonance imaging (MRI) of lung perfusion in children with cystic fibrosis (CF) using contrast-enhanced 3D MRI. Correlation assessment of perfusion changes with structural abnormalities. Eleven CF patients (9 f, 2 m; median age 16 years) were examined at 1.5 T. Morphology: HASTE coronal, transversal (TR/TE/alpha/ST: 600 ms/28 ms/180 degrees /6 mm), breath-hold 18 s. Perfusion: Time-resolved 3D GRE pulse sequence (FLASH, TE/TR/alpha: 0.8/1.9 ms/40 degrees ), parallel imaging (GRAPPA, PAT 2). Twenty-five data sets were acquired after intravenous injection of 0.1 mmol/kg body weight of gadodiamide, 3-5 ml/s. A total of 198 lung segments were analyzed by two radiologists in consensus and scored for morphological and perfusion changes. Statistical analysis was performed by Mantel-Haenszel chi-square test. Results showed that perfusion defects were observed in all patients and present in 80% of upper, and 39% of lower lobes. Normal lung parenchyma showed homogeneous perfusion (86%, P<0.0001). Severe morphological changes led to perfusion defects (97%, P<0.0001). Segments with moderate morphological changes showed normal (53%) or impaired perfusion (47%). In conclusion, pulmonary perfusion is easy to judge in segments with normal parenchyma or severe changes. In moderately damaged segments, MRI of lung perfusion may help to better assess actual functional impairment. Contrast-enhanced 3D MRI of lung perfusion has the potential for early vascular functional assessment and therapy control in CF patients.

Adolescent↗

Therapy monitoring using dynamic MRI: analysis of lung motion and intrathoracic tumor mobility before and after radiotherapy.

A frequent side effect after radiotherapy of lung tumors is a decrease of pulmonary function accompanied by dyspnea due to developing lung fibrosis. The aim of this study was to monitor lung motion as a correlate of pulmonary function and intrathoracic tumor mobility before and after radiotherapy (RT) using dynamic MRI (dMRI). Thirty-five patients with stage I non-small-cell lung carcinoma were examined using dMRI (trueFISP; three images/s). Tumors were divided into T1 and T2 tumors of the upper, middle and lower lung region (LR). Maximum craniocaudal (CC) lung dimensions and tumor mobility in three dimensions were monitored. Vital capacity (VC) was measured and correlated using spirometry. Before RT, the maximum CC motion of the tumor-bearing hemithorax was 5.2 +/- 0.9 cm if the tumor was located in the lower LR (middle LR: 5.5 +/- 0.8 cm; upper LR: 6.0 +/- 0.6 cm). After RT, lung motion was significantly reduced in the lower LR (P < 0.05). Before RT, the maximum CC tumor mobility was significantly higher in tumors of the lower LR 2.5 +/- 0.6 vs. 2.0 +/- 0.3 cm (middle LR; P < 0.05) vs. 0.7 +/- 0.2 cm (upper LR; P < 0.01). After RT, tumor mobility was significantly reduced in the lower LR (P < 0.01) and in T2 tumor patients (P < 0.05). VC showed no significant changes. dMRI is capable of monitoring changes in lung motion that were not suspected from spirometry. This might make the treatment of side effects possible at a very early stage. Changes of lung motion and tumor mobility are highly dependent on the tumor localization and tumor diameter.

Adult↗

Dynamic coil selection for real-time imaging in interventional MRI.

MR-guided intravascular interventions require image update rates of up to 10 images per second, which can be achieved using parallel imaging. However, parallel imaging requires many coil elements, which increases reconstruction times and thus compromises real-time image reconstruction. In this study a dynamic coil selection (DCS) algorithm is presented that selects a subset of receive coils to reduce image reconstruction times. The center-of-sensitivity coordinates and the relative signal intensities are determined for each coil in a prescan. During the intervention m coils are selected for reconstruction using a coil ranking based on the distance to the current slice or catheter position. In a phantom experiment for m = 6, an optimal signal-to-background ratio (SBR) was achieved and foldover artifacts were avoided. In three animal experiments involving catheter manipulation in the aorta and the right heart chamber, the anatomy was successfully visualized at frame rates of about 5 Hz using active catheter tracking.

Algorithms↗

[Microstructure of the lung: diffusion measurement of hyperpolarized 3Helium].

Imaging methods to study the lung are traditionally based on x-ray or on radioactive contrast agents. Conventional magnetic resonance imaging (MRI) has only limited applications for lung imaging because of the low tissue density of protons concentration of hydrogen atoms, which are usually the basis for the imaging. The introduction of hyperpolarized noble gases as a contrast agent in MRI has opened new possibilities for lung diagnosis. The present paper describes this new technique. Diffusion-weighted MRI for assessment of the lung microstructure is presented here as an example of the new possibilities of functional imaging. Studies to determine the sensitivity of the diffusion measurement and regarding the correlation with traditionally established methods are also presented, along with results of the measurement of the reproducibility determined in a clinical pilot study on healthy volunteers and patients. Furthermore, a pilot measurement of the 3He diffusion tensor in the lung is presented.

Humans↗

Investigation of retrospective respiratory gating techniques for acquisition of thin-slice 4D-Multidetector-computed Tomorgraphy (MDCT) of the lung: Feasibility study in a large animal model.

Respiratory gated 3D-MDCT acquisition of the whole chest over time (4D-MDCT) allow retrospective reconstruction of raw data at any point of the respiratory cycle might be beneficial in severely ill or sedated patients. Aim of this feasibility study was to investigate 2 prototype devices as input for retrospective respiratory gating in order to calculate lung volumes (LVs) and mean lung densities (MLDs) over time. Sixteen-row MDCT data were acquired in 5 ventilated pigs using a laser sensor and charge-coupled devine (CCD) camera and retrospectively reconstructed at every 10% of the respiratory cycle. Semiautomatic segmentation of the 3D data sets was performed, and LV and MLD were calculated. Data acquisition was successful in all cases. The mean difference of LV between maximum inspiration and expiration was 246 and 240 mL (laser and CCD, respectively). The mean difference of MLD between inspiration and expiration was 70 (laser) and 67 (CCD) HU. The lowest MLD was found at the beginning of the respiratory cycle (0%) for laser, and at 90% for CCD. Both gating devices allowed for reliable 4D-MDCT image acquisition. No differences were found for calculated LV and MLD, whereas the respiratory cycle was more precisely detected using the laser based gating device.

Animals↗

Monitoring of lung motion in patients with malignant pleural mesothelioma using two-dimensional and three-dimensional dynamic magnetic resonance imaging: comparison with spirometry.

PURPOSE: To monitor lung motion in patients with malignant pleural mesothelioma (MPM) before and after chemotherapy (CHT) using 2-dimensional (2D) and 3-dimensional (3D) dynamic MRI (dMRI) in comparison with spirometry. METHODS AND MATERIALS: Twenty-two patients with MPM were examined before CHT, as well as after 3 and 6 CHT cycles (3 months and 6 months) using 2D dMRI (trueFISP; 3 images/s) and 3D dMRI (FLASH 3D, 1 slab (52 slices)/s) using parallel imaging in combination with view-sharing technique. Maximum craniocaudal lung dimensions (2D) and lung volumes (3D) were monitored, separated into the tumor-bearing and nontumor-bearing hemithorax. Vital capacity (VC) was measured for comparison using spirometry. RESULTS: Using 2D technique, there was a significant difference between the tumor-bearing and the nontumor-bearing hemithorax before CHT (P < 0.01) and after 3 CHT cycles (P < 0.05), whereas difference was not significant in the second control. In the tumor-bearing hemithorax, mobility increased significantly from the status before versus after 3 CHT cycles (4.1 +/- 1.1 cm vs. 4.8 +/- 1.4 cm, P < 0.05). Using 3D technique, at maximum inspiration, the volume of the tumor-bearing hemithorax was 0.6 +/- 0.4 L and of the nontumor-bearing hemithorax 1.25 +/- 0.4 L before CHT. In the follow-up exams, these volumes changed to 1.05 +/- 0.4 L (P < 0.05) and 1.4 +/- 0.5 L, respectively. Using spirometry, there was no significant change in VC (1.9 +/- 0.4 L vs. 2.2 +/- 0.7 L vs. 2.2 +/- 0.9 L). CONCLUSION: dMRI is capable of monitoring changes in lung motion and volumetry in patients with MPM not detected by global spirometry. Thus, dMRI is proposed for use as a further measure of therapy response.

Aged↗

Free-breathing three-dimensional computed tomography of the lung using prospective respiratory gating: charge-coupled device camera and laser sensor device in an animal experiment.

PURPOSE: The aim was to investigate the feasibility and image quality of prospective respiratory gating for 3-D computed tomography (CT) of the lung. MATERIAL AND METHODS: Eight anesthetized pigs underwent prospectively gated multidetector computed tomography using 2 devices: a charge-coupled device (CCD) camera and a laser sensor. The output signal of both gating devices was connected to the scanner instead of ECG unit. Inspiratory and expiratory images were obtained during "free-breathing" and analyzed in MPR mode for sharpness of bronchi, diaphragm and lung using a 4-point-score (1, excellent to 4, severe artifacts). RESULTS: The CCD camera worked in all animals. Using the laser sensor, only 50% of expiratory scans could be acquired. All acquired images showed excellent sharpness (CCD camera vs. laser sensor) for trachea (1.1 +/- 0.3 vs. 1.3 +/- 0.5), bronchi (1.4 +/- 0.7 vs. 1.8 +/- 0.6), lung fissures (1.0 vs. 1.1 +/- 0.3), and lung parenchyma (1.0 +/- 0.2 vs. 1.4 +/- 0.6), and minor to major artifacts for diaphragm (1.5 +/- 0.8 vs. 2.0 +/- 1.0, P < 0.05) and pericardial lung structures (1.9 +/- 0.7 vs. 2.3 +/- 0.5). CONCLUSION: High image quality for inspiratory and expiratory scans was achieved by free-breathing 3-D CT of the lung using noncontact prospective respiratory gating.

Animals↗

MRI Measurement of the hemodynamics of the pulmonary and systemic arterial circulation: influence of breathing maneuvers.

OBJECTIVE: The purpose of this study was to use phase-contrast MRI to evaluate the influence of various breathing maneuvers on the hemodynamics of the pulmonary and systemic arterial circulation. SUBJECTS AND METHODS: Twenty-five volunteers were examined with phase-contrast MRI. Flow measurements were acquired in the aorta, pulmonary trunk, and left and right pulmonary arteries during deep, large-volume inspiratory breath-hold, expiratory breath-hold, and smooth respiration (no breath-hold). Parameters assessed were peak velocity, blood flow, velocity gradient, and acceleration time. RESULTS: Pulmonary blood flow and peak velocity were significantly reduced during inspiratory breath-hold and expiratory breath-hold compared with no breath-hold (p < 0.01). Pulmonary velocity gradient in inspiratory breath-hold was significantly (p </= 0.01) lower than in expiratory breath-hold and no breath-hold. There was no difference in velocity gradient between expiratory breath-hold and no breath-hold. Peak velocity in the aorta was lowest with no breath-hold. Velocity gradient was highest in expiratory breath-hold, and no breath-hold had the smallest SD. Acceleration time in the pulmonary trunk showed no difference between inspiratory breath-hold, expiratory breath-hold, and no breath-hold. Blood flow distribution to the left (45-47%) and to the right (53-55%) lung was not influenced by breathing maneuver. CONCLUSION: Measurements during smooth respiration showed the smallest SD. Therefore, no-breath-hold measurements should be considered for assessment of hemodynamics in clinical practice.

Adult↗

Value of high spatial and high temporal resolution magnetic resonance angiography for differentiation between idiopathic and thromboembolic pulmonary hypertension: initial results.

Differentiation between different forms of pulmonary hypertension (PH) is essential for correct disease management. The goal of this study was to elucidate the clinical impact of high spatial resolution MR angiography (SR-MRA) and time-resolved MRA (TR-MRA) to differentiate between patients with chronic thromboembolic PH (CTEPH) and idiopathic pulmonary arterial hypertension (IPAH). Ten PH patients and five volunteers were examined. Twenty TR-MRA data sets (TA 1.5 s) and SR-MRA (TA 23 s) were acquired. TR-MRA data sets were subtracted as angiography and perfusion images. Evaluation comprised analysis of vascular pathologies on a segmental basis, detection of perfusion defects, and bronchial arteries by two readers in consensus. Technical evaluation comprised evaluation of image quality, signal-to-noise ratio (SNR) measurements, and contrast-media passage time. Visualization of the pulmonary arteries was possible down to a subsegmental (SR-MRA) and to a segmental (TR-MRA) level. SR-MRA outperformed TR-MRA in direct visualization of intravascular changes. Patients with IPAH predominantly showed tortuous pulmonary arteries while in CTEPH wall irregularities and abnormal proximal-to-distal tapering was found. Perfusion images showed a diffuse pattern in IPAH and focal defects in CTEPH. TR-MRA and SR-MRA resulted in the same final diagnosis. Both MRA techniques allowed for differentiation between IPAH and CTEPH. Therefore, TR-MRA can be used in the clinical setting, especially in dyspneic patients.

Diagnosis, Differential↗

Assessment of reproducibility and stability of different breath-hold maneuvres by dynamic MRI: comparison between healthy adults and patients with pulmonary hypertension.

To assess the stability and reproducibility of different breath-hold levels in healthy volunteers and patients using dynamic MRI (dMRI). In ten healthy volunteers and ten patients with pulmonary hypertension (PH) and normal lung function craniocaudal intrathoracic distances (CCD) were measured during inspiratory and expiratory breath-hold (15 s) (in healthy volunteers additionally at a self-chosen mid-inspiratory breath-hold) using dMRI (trueFISP, three images/s). To evaluate stability and intraobserver reproducibility of the different breath-hold levels, CCDs, time-distance curves, confidence intervals (CIs), Mann-Witney U test and regression equations were calculated. In healthy volunteers there was a substantial decrease of the CCD during the inspiratory breath-hold in contrast to the expiratory breath-hold. The CI at inspiration was 2.84+/-1.28 in the right and 2.1+/-0.68 in the left hemithorax. At expiration the CI was 2.54+/-1.18 and 2.8+/-1.48. Patients were significantly less able to hold their breath at inspiration than controls (P<0.05). In patients CI was 4.53+/-4.06 and 3.46+/-2.21 at inspiration and 4.45+/-4.23 and 4.76+/-3.73 at expiration. Intraobserver variability showed no significant differences either in patients or in healthy subjects. Reproducibility was significantly lower at a self-chosen breath-hold level of the healthy volunteers. DMRI is able to differentiate stability and reproducibility of different breath-hold levels. Expiratory breath-hold proved to be more stable than inspiratory breath-hold in healthy volunteers and patients.

Adult↗