PubMed Health⌕ Search

Biomedical subjects

Selim Yalçinkaya

Publications and source records attributed to Selim Yalçinkaya.

5 recordsLinked to original sources

[Risk stratification in non-ST segment elevation myocardial infarction].

Patients with either unstable angina or non ST elevation myocardial infarction are usually submitted to the emergency department with similar symptoms and signs. Generally cardiac enzyme determinations can differentiate these two conditions. Elevation of these enzymes and their detection in blood stream takes a certain amount of time. A number of studies demonstrated lately that the high risk patients benefit more aggressive treatment modalities. Risk stratification and identification of the high risk patients became an essential part of the evaluation in emergency departments.

Angina, Unstable↗

[Hemodynamic performance of mechanical aortic valves in narrow aortic annulus cases].

OBJECTIVE: Small-sized prosthetic valves used in aortic valve position usually cause a high transvalvular gradient. This situation, especially in people with a high body surface area, causes a patient-prosthetic valve mismatch. In this study, hemodynamic performances of the two new generation bileaflet, small size mechanical valves were evaluated during rest and stress conditions. METHODS: Eighteen patients with implanted 21-mm St. Jude HP (11 cases) and Sorin Bicarbon (7 cases) prosthetic valves in aortic position were evaluated at rest and during dobutamine infusion, 16.3+/-5.5 months after the operation. Dobutamine infusion was started at a dose of 5 microg/kg/min. The infusion rate was increased every 15 minutes up to 10-20-30 microg/kg/min. Maximum gradient, mean gradient, effective valve area (EVA), effective valve area index (EVAI) and performance index (PI) were calculated during rest and maximum dobutamine infusion rate. RESULTS: When the rest and dobutamine infusion measurements were compared, the maximum and mean gradients were found to be increased moderately, but EVA, EVAI, PI values did not change with increasing heart rates. For St. Jude valve; maximum gradient increased from 30.5+/-6.5 mmHg to 74.7+/-33.6 mmHg (p=0.03) and mean gradient increased from 17.9+/-3.8 to 40.8+/-23.8 mmHg (p=0.03). For Sorin Bicarbon valve; maximum gradient increased from 31.7+/-13.3 mmHg to 52.0+/-11.2 mmHg (p=0.01), mean gradient increased from 16.1+/-6.4 mmHg to 28.8+/-1.0 mmHg (p=0.01). The difference was not significant between the two valves with respect to measured parameters during rest and maximum dobutamine infusion. CONCLUSION: According to our findings, 21-mm Sorin Bicarbon and St. Jude HP mechanical bileaflet valves have good hemodynamic performance during exercise and these types of valves seem to be appropriate for patients with small aortic annulus.

Adult↗

Comparison of initial efficacy and long-term follow-up of heparin-coated Jostent with conventional NIR stent.

The implantation of heparin-coated stents was reported to be well tolerated, but there are conflicting results about acute in-hospital complications. (sub)acute thrombosis rates, and long-term follow-up compared to uncoated stents. We compared the angiographic and clinical results after coronary placement of two stent models: the heparin-coated premounted Jostent and the uncoated premounted NIR stent. Of 710 patients revascularized, a total of 426 patients received Jostent (n = 230) or NIR stent (n = 196) implantation. The primary end points were acute or subacute thrombosis, urgent CABG, AMI or death, while the secondary end points were the comparison of the restenosis rates of the stents at the 6th month and of the functional angina classification of the stent groups at the 1st, 6th and 12th months. There were no significant differences between the Jostent and NIR stent groups regarding angiographic and procedural success. Acute thrombosis rates in the Jostent and NIR stent groups were similar while no subacute thrombosis was observed in either group. The major adverse cardiac event rates of the groups also did not differ. Angiographic restenosis occurred in 17% of the Jostent group and 16% of the NIR stent group (NS). The combined clinical and angiographic restenosis rate was also similar between the Jo and NIR groups (19% and 18%, respectively). Comparison of functional angina classes at the 1st, 6th and 12th months revealed no significant difference between the study groups. In conclusion, when compared with implantation of an uncoated premounted NIR stent, implantation of a heparin-coated premounted Jostent does not provide any more benefit with respect to initial efficacy, sub(acute) thrombosis and 6-month restenosis rates and 12-month clinical outcomes.

Aged↗

Left atrial function as a predictor of haemodynamic response in patients with mitral stenosis: a dobutamine stress echocardiographic study.

OBJECTIVE: The mechanisms of the different haemodynamic and clinical responses to dobutamine infusion in mitral stenosis (MS) are not clearly established. The aim of this study was to evaluate the relation between left atrial (LA) function and haemodynamic response in patients with MS during dobutamine infusion. METHODS AND RESULTS: Forty-two consecutive moderately symptomatic patients (33 women, 9 men; mean age 46+/-9, range from 26 to 66), New York Heart Association (NYHA) class II with MS (mean mitral valve area 1.7+/-0.1 cm2) were evaluated with dobutamine stress echocardiography. Haemodynamic measurements were obtained at rest and during peak dobutamine infusion. LA fractional shortening at rest was used as an index of global LA function. Group I consisting of patients with significantly elevated pulmonary artery pressure (> 60 mm Hg) and mean transmitral gradient (> 15 mm Hg) at peak dobutamine infusion were defined as haemodynamically serious MS. Group II consisted of the remaining 30 patients whose haemodynamic data were below these levels. While baseline haemodynamic parameters and mitral valve characteristics were not different between the two groups, LA fractional shortening was significantly lower (18.9+/-2.8 vs. 32.3+/-5.1%, p<0.0001) and left atrial dimension was significantly larger in group I (49.7+/-2.3 mm vs 43.6+/-5.3 mm, p<0.0001). Left atrial fractional shortening was negatively correlated with the increase in mean transmitral gradient (r:-0.58, p<0.01). When the patients were divided using a LA fractional shortening level of 25% as the cut-off point, we observed that the patients with low LA fractional shortening had a greater increase in mean transmitral gradient (7.3+/-3.1 mm Hg vs. 4.6+/-1.4 mm Hg), p = 0.005) and pulmonary artery pressure (22.4+/-3.5 mm Hg vs. 16.1+/-8.5 mm Hg, p = 0.001) compared to the patients with high LA fractional shortening. Based on these haemodynamic results, management was changed in 12 patients (28%): 5 underwent percutaneous mitral balloon commissurotomy and 7 received intensive medical treatment. CONCLUSIONS: The present study demonstrates that haemodynamic response during dobutamine stress echocardiography correlates with LA fractional shortening in patients with MS. The evaluation of left atrial function at rest in patients with ambiguous symptoms and mild mitral stenosis may be useful in clinical decision making. Atrial dysfunction at rest may predict the haemodynamic response during stress echo in these patients.

Adrenergic beta-Agonists↗