PubMed Health⌕ Search

Biomedical subjects

Sen Ji

Publications and source records attributed to Sen Ji.

6 recordsLinked to original sources

Atrioventricular nodal reentrant tachycardia in patients referred for atrial fibrillation ablation: response to ablation that incorporates slow-pathway modification.

BACKGROUND: Although the most common sites of atrial ectopy that trigger atrial fibrillation (AF) are in or around the pulmonary veins (PVs), atrioventricular nodal reentrant tachycardia (AVNRT) can also cause or coexist with AF. We sought to characterize patients with AF and AVNRT and assess clinical outcomes after ablation. METHODS AND RESULTS: To determine the prevalence of concomitant AVNRT and AF, 629 consecutive patients referred for catheter ablation between November 1998 and March 2005 were studied. Electrophysiological studies with programmed stimulation during isoproterenol infusion identified atrial ectopy that initiated AF and the presence of inducible AVNRT. AF ablation consisted of proximal isolation of PVs and elimination of any non-PV trigger of AF, including AVNRT. There were 27 patients (4.3%) who had inducible AVNRT at the time of AF ablation. Of these, 13 underwent AVNRT ablation without PV isolation. Compared with the rest of the cohort, patients with AVNRT and AF were younger at the time of symptom onset (age 36.8+/-13.8 versus 48.2+/-11.7 years; P<0.01). Freedom from AF with or without previously ineffective antiarrhythmic medication was similar in both groups (96.3% versus 90.7%; mean follow-up 21.4+/-9.4 months); however, patients with AVNRT targeted for ablation were more likely to be AF free while not taking any antiarrhythmic medication after a single procedure during the follow-up period (87.5% versus 54.7%; P<0.01) and had fewer complications (0% versus 2.5%; P=0.30). Twelve of the 13 patients who underwent slow-pathway ablation without left atrial ablation remained AF free without the need for antiarrhythmic medication after a single procedure. CONCLUSIONS: AVNRT is an uncommon AF trigger seen more frequently in younger patients. Ablation of AVNRT in patients with AF was associated with improved outcomes compared with those with other triggers of AF.

Adult↗

Beyond coronary sinus angiography: the value of coronary arteriography and identification of the pericardiophrenic vein during left ventricular lead placement.

OBJECTIVE: The purpose of this study was to define the role coronary arteriography (venous phase) for improving the success of left ventricular (LV) lead implantation and to define the value of identifying the pericardiophrenic vein for optimal LV lead placement in biventricular (bi-v) device implantation. METHODS: Seventy-seven patients underwent bi-v device implantation between July 2002 and October 2003. If the coronary sinus (CS) could not be accessed, then left coronary arteriography was performed during the same procedure. CS access was guided by venous phase images of the coronary arteriogram. The pericardiophrenic vein was identified by selective cannulation or direct visualization. Patients with Cr > 1.5 had gadolinium used as the contrast agent. RESULTS: Seventy-five successful implants were performed (97%). In seven patients (9%) repeated attempts at retrograde cannulation of the CS failed (attempt time 130 +/- 20 minute, mean +/- SD). In these patients, coronary arteriography helped define the location of the CS, which was subsequently successfully cannulated. In six patients the pericardiophrenic vein was identified either during occlusion venography of the CS (postthoracotomy, veno-venous collaterals, n = 2) or during selective cannulation of the pericardiophrenic vein (using a DAIG Csl catheter, n = 4). The vein was directly visualized in three patients who underwent surgical LV lead implantation. LV leads in all these cases were implanted in areas not overlying the preidentified pericardiophrenic vein. During follow-up, none of these patients had evidence of phrenic nerve stimulation. CONCLUSIONS: Intraoperative left coronary arteriography increases the success of CS cannulation. Identification of the pericardiophrenic vein is a useful method to avoid phrenic nerve stimulation.

Contrast Media↗

The molecular basis of cardiac arrhythmias in patients with cardiomyopathy.

Cardiac arrhythmias are a leading cause of mortality and morbidity in Western society. In some specific instances, these arrhythmias are caused by abnormalities of cardiac ion channels, such as sodium, calcium, and potassium channels, which carry ionic currents and are fundamental determinants of cardiac excitability. Abnormalities of these ion channels are attributed to mutations in the genes encoding the channel protein and cause altered function of channels, which can predispose to arrhythmias. During heart failure, many channels also malfunction because of altered expression, resulting in lethal arrhythmias.

Cardiomyopathy, Dilated↗

Percutaneous epicardial mapping during ablation of difficult accessory pathways as an alternative to cardiac surgery.

OBJECTIVES: The aim of this study was to define the role of percutaneous epicardial mapping for the ablation of previous failed ablation of accessory pathways. BACKGROUND: Cardiac surgery is the only curative option for failed radiofrequency (RF) catheter ablation of accessory pathway (AP)-mediated tachycardias. We investigated a combined percutaneous epicardial and endocardial approach for failed AP ablations. METHODS: We present our experience in a series of 6 cases (7 APs) with previous failed attempts at catheter ablation (median 2 attempts, range 1-4) and persistent symptomatic tachycardias. Endocardial mapping of the APs was performed using conventional techniques. Sites with local electrograms suggestive of AP location were selected. When initial endocardial mapping was not successful for ablation of the pathway, percutaneous transthoracic pericardial puncture was performed via a subxiphoid approach, and an ablation catheter was positioned at the epicardial aspect of the putative AP location for epicardial-endocardial electrogram comparison. Endocardial RF energy was applied to locations considered appropriate. Epicardial RF applications were delivered when endocardial applications failed. Coronary arteriography was performed to assess the proximity of coronary arteries to the ablation catheter. RESULTS: APs were located in the right free wall (4 patients, 5 APs) and the right (1 patient) and left (1 patient) posteroseptal regions. In all patients, epicardial mapping assisted in identifying successful ablation sites. In 3 patients, the earliest atrial activation during orthodromic tachycardia was present in an epicardial electrogram. Successful AP ablation was achieved with an epicardial RF application in 2 patients, either alone or with simultaneous endocardial-epicardial delivery. In the remaining 4 patients, APs were successfully ablated endocardially after epicardial mapping. These patients represent 18% of all cases referred to our institution for ablation of previously failed accessory pathways (6/32 patients). CONCLUSIONS: A combined endocardial-epicardial approach to mapping and RF ablation can facilitate successful endocardial ablation in most cases. In selected cases, APs can be ablated by epicardial delivery of RF. Epicardial mapping is an effective alternative to cardiac surgery for patients in whom prior attempts at AP ablation have failed.

Adolescent↗

Electrophysiological characterization of cardiac veins in humans.

BACKGROUND: The coronary sinus is a complex structure with a surrounding myocardial coat and muscle bundles that course within it. The purpose of this study was to evaluate the electrical activity of the coronary sinus (CS), great cardiac vein (GCV) and related structures, such as the Vein of Marshall (VOM). METHODS AND RESULTS: Data obtained from adult ( n = 114) and pediatric patients ( n = 16) were analyzed. The width of atrial electrograms (EGMs) within the CS at a basic pacing cycle length of 600 ms was 46 +/- 7.4 ms (mean +/- SD) vs. 29.7 +/- 6.3 ms in the GCV ( p < 0.01). With decremental pacing the width of the EGM within the CS at 300 ms increased to 66.6 +/- 8.5 ms ( p < 0.1 compared to CS EGM at pacing cycle length of 600 ms). The width of the EGM within the GCV increased from 29.7 +/- 6.3 ms at a pacing cycle length of 600 ms to 34.6 +/- 6.0 at 300 ms ( p = NS). There were no significant differences in the atrial EGM width between CS and GCV in the pediatric patients. CONCLUSIONS: We conclude that atrial electrograms are wider in the CS but not in the GCV. This finding can be explained by the presence of a myocardial coat around the CS. The rate response characteristics of the atrial electrograms within the CS are consistent with a lack of tight coupling between muscle bundles and the CS musculature. Further, the absence of such differences in pediatric patients could partly explain relative differences in types of supraventricular arrhythmias seen in different age groups.

Adolescent↗