PubMed Health⌕ Search

Biomedical subjects

Seong-Eun Kim

Publications and source records attributed to Seong-Eun Kim.

7 recordsLinked to original sources

High-resolution DTI of a localized volume using 3D single-shot diffusion-weighted STimulated echo-planar imaging (3D ss-DWSTEPI).

Diffusion tensor MRI (DTI) using conventional single-shot (SS) 2D diffusion-weighted (DW)-EPI is subject to severe susceptibility artifacts. Multishot DW imaging (DWI) techniques can reduce these distortions, but they generally suffer from artifacts caused by motion-induced phase errors. Parallel imaging can also reduce the distortions if the sensitivity profiles of the receiver coils allow a sufficiently high reduction factor for the desired field of view (FOV). A novel 3D DTI technique, termed 3D single-shot STimulated EPI (3D ss-STEPI), was developed to acquire high-resolution DW images of a localized region. The new technique completes k-space acquisition of a limited 3D volume after a single diffusion preparation. Because the DW magnetization is stored in the longitudinal direction until readout, it undergoes T(1) rather than T(2) decay. Inner volume imaging (IVI) is used to limit the imaging volume. This reduces the time required for EPI readout of each complete k(x)-k(y) plane, and hence reduces T(2)(*) decay during the readout and T(1) decay between the readout of each k(z). 3D ss-STEPI images appear to be free of severe susceptibility and motion artifacts. 3D ss-STEPI allows high-resolution DTI of limited volumes of interest, such as localized brain regions, cervical spinal cord, optic nerve, and other extracranial organs.

Algorithms↗

A case of gastric tuberculosis mimicking advanced gastric cancer.

Tuberculosis of the stomach is quite rare, both as a primary or secondary infection. It can present as a facet of a multiorgan disease process or may result from immunodeficiency. Here, we report a rare, interesting case of gastric tuberculosis which morphologically mimicked advanced gastric cancer in a young, immunocompetent patient presenting with hematemesis and melena. The disease was diagnosed by biopsy, and responded well to antituberculosis medication without surgery. Clinicians must bear in mind that, even in the absence of immunodeficiency, as in this case, tuberculosis can involve any site in the gastrointestinal tract and may present with a variety of characteristics. Gastric tuberculosis should always be part of the differential diagnosis of chronic infiltrative lesions in the stomach.

Adult↗

High-resolution DTI with 2D interleaved multislice reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI).

Diffusion tensor MRI (DTI), using single-shot 2D diffusion weighted-EPI (2D ss-DWEPI), is limited to intracranial (i.c.) applications far from the sinuses and bony structures, due to the severe geometric distortions caused by significant magnetic field inhomogeneities at or near the tissue-air or tissue-bone interfaces. Reducing these distortions in single-shot EPI by shortening the readout period generally requires a reduced field of view (and the potential of wraparound artifact) in the phase-encoding direction and/or reduced spatial resolution. To resolve the problem, a novel 2D reduced FOV single-shot diffusion-weighted EPI (2D ss-rFOV-DWEPI) pulse sequence applicable for high resolution diffusion-weighted MRI of local anatomic regions, such as brainstem, cervical spinal cord, and optic nerve, has been developed. In the proposed technique, time-efficient interleaved acquisition of multiple slices with a limited FOV was achieved by applying an even number of refocusing 180 degrees pulses with the slice-selection gradient applied in the phase-encoding direction. The two refocusing pulses used for each slice acquisition were separated by a short time interval (typically less than 45 ms) required for the 2D EPI echotrain acquisition. The new technique can be useful for high resolution DTI of various anatomies, such as localized brain structures, cervical spinal cord, optic nerve, heart, or other extra-cerebral organ, where conventional 2D ss-DWEPI is limited in usage due to the severity of image distortions.

Algorithms↗

Improved accuracy and consistency in T1 measurement of flowing blood by using inversion recovery GE-EPI.

Problems associated with techniques currently used to measure the T1 of flowing blood are evaluated and a method to improve the consistency and repeatability of measurements is presented. Similar to some currently used techniques, the pulse sequence employs a nonselective adiabatic inversion pulse followed by a series of ECG-gated gradient echo EPI (echo planar imaging) images to obtain images where the blood (fluid) signal exhibits a T1-dependent inversion recovery signal from which the spin lattice relaxation constant (T1) of the flowing fluid can be measured. The new method combines curve fitting with a measure of the curve null point to acquire more accurate and consistent T1 values. Simulation and experimental results show that this combined fitting-nulling method is more stable and consistent in measuring the T1 of flowing fluid. The feasibility of temperature measurement of a flowing fluid based on the temperature dependence of the T1 of water protons is shown in this paper. ECG gating is used to reduce the effects of cyclic intensity changes for measurement of T1 in pulsatile flowing blood.

Blood Flow Velocity↗

Triple contrast technique for black blood imaging with double inversion preparation.

This work reports on the development of a pulse sequence to simultaneously acquire proton density, T(1), and T(2) weighted images in a single magnetization prepared fast spin echo acquisition. The technique is based upon the application of a magnetization preparation consisting of a global inversion followed by slice-selective 180 degrees and 90 degrees pulses to prepare the signal of specific slices. Slices are acquired in an interleaved manner with time delays appropriate for the desired image contrasts. Data acquisition is repeated for all combinations of slice interleaving covering the region of interest until images from all slice locations have been acquired with all desired image contrasts. The multiple image contrasts obtained with this technique should be useful in applications where discrimination between different types of tissue components is desired, such as in the analysis of plaque in cervical carotid artery disease.

Arteriosclerosis↗

The need for phase-encoding flow compensation in high-resolution intracranial magnetic resonance angiography.

PURPOSE: To demonstrate that the time delay between phase and frequency encoding and the presence of pulsatile blood flow in high-resolution time-of-flight (TOF) imaging of the intracranial arteries (especially near the circle of Willis) can distort the appearance of blood vessels and result in a cross-hatch-appearing artifact in surrounding tissue. MATERIALS AND METHODS: Two techniques to reduce the artifact, tri-directional flow compensation (3DFC) and elliptical-centric (EC) phase-encoding order, are investigated in five volunteer studies. RESULTS: 3DFC eliminates the pulsation-related artifacts and the vessel distortion. A residual amplitude variation artifact is observed. EC phase encoding nearly eliminates the pulsatile motion-related artifact, but it does not eliminate vessel distortion. CONCLUSION: The combination of 3DFC and EC phase encoding appears to provide the greatest artifact reduction in the five volunteer studies performed.

Adult↗

High-resolution diffusion-weighted 3D MRI, using diffusion-weighted driven-equilibrium (DW-DE) and multishot segmented 3D-SSFP without navigator echoes.

In this work we report on the development of a novel technique for high-resolution diffusion-weighted (DW) MRI based upon 3D steady-state free precession (3D-SSFP). First the 3D-SSFP acquisition was segmented (each segment consisting of a series of RF pulses and gradient-recalled echoes), and then DW-driven equilibrium (DE) was inserted between each segment. The in-plane imaging matrix was typically 256 x 192 or 256 x 160, which resulted in high-resolution DW images. The DW-DE segmented SSFP signal was contaminated by the non-DW magnetization, which recovered and contributed signal during the readout train (T(1) contamination). Center-out slice encoding was used to place the greatest diffusion weighting at the center of k-space. A numerical simulation and supporting experiments were performed to evaluate the relationship of the transverse magnetization to imaging parameters, such as the b-value, echo-train length (ETL), echo-train (group) repetition time (TR(g)), and RF excitation TR (Delta t). Both the numerical simulation and the experiments suggested that the effect of T(1) contamination would be reduced with a longer TR(g), smaller b-value, shorter ETL, and center-out slice phase encoding. Phase errors caused by microscopic motions during the diffusion gradients were converted into amplitude errors by the tip-up pulse at the end of the diffusion-weighting segment. As a result, small bulk motions, such as CSF pulsation, did not cause motion-related ghosting artifacts, which would be typical in images from other multishot DWI techniques. This technique can be used for high-resolution DWI of nonbrain anatomies.

Artifacts↗