PubMed Health⌕ Search

Biomedical subjects

Serdar Uşümez

Publications and source records attributed to Serdar Uşümez.

5 recordsLinked to original sources

Effect of light-emitting diode on bond strength of orthodontic brackets.

The aim of this study was to evaluate the effect of light-emitting diode (LED) light curing on shear bond strength (SBS) of orthodontic brackets bonded to teeth. Light exposure of 40 seconds from a conventional halogen-based light-curing unit was used as a control. Eighty human premolars were divided into four groups of 20 each. Brackets were bonded to acid-etched teeth with Transbond XT light-cured adhesive. In the first group, the adhesive was light cured for 40 seconds with a conventional halogen unit (XL3000, 3M). In the other three groups, adhesive was cured with a commercial LED unit (Elipar FreeLight, 3M ESPE) for 10, 20, or 40 seconds. SBS of brackets was measured on a universal testing machine and recorded in megapascals. Adhesive remnant index (ARI) scores were determined after failure of brackets. Data were analyzed using analysis of variance and chi-square tests. No statistically significant differences were found among the SBS values of halogen-based light-cured (13.1 +/- 3.1 MPa) and 20- and 40-second LED-cured (13.9 +/- 4.8 MPa and 12.7 +/- 5.1 MPa) specimens (P > .05). However, 10 seconds of LED curing yielded significantly lower SBS (P < .05). No statistically significant differences were found between the ARI scores among groups. The results of this study are promising for the orthodontic application of LED-curing units, but further compatibility and physical characteristic studies of various orthodontic adhesives and clinical trials should be performed before validation.

Dental Bonding↗

Can previously bleached teeth be bonded safely?

The purpose of our study was to determine the effect of a 35% hydrogen peroxide bleaching agent on the shear bond strength of metallic orthodontic brackets. Sixty premolars were randomly divided into 3 groups of 20 each. Teeth in group A were etched with 37% phosphoric acid before bonding metallic premolar brackets. Teeth in the other 2 groups were bleached with a 35% hydrogen peroxide in-office bleaching agent according to the manufacturer's recommendations. Twenty bleached teeth (group B) were bonded immediately, and the other 20 (group C) were stored in artificial saliva for 30 days before bonding. Shear bond strength of these brackets was measured on a universal testing machine and recorded in MPa. Adhesive remnant index (ARI) scores were determined after the brackets failed. Data were analyzed with analysis of variance (ANOVA) and chi-square tests. The shear bond strength values of groups A, B, and C were 12.9 +/- 3.4, 12.0 +/- 4.6, and 14.8 +/- 4.0 MPa, respectively. Results of ANOVA showed no statistically significant differences in shear bond strengths between groups (P >.05). ARI scores were significantly different in all groups. The unbleached group's failures were primarily at the bracket/adhesive interface, whereas the bleached groups either showed cohesive failures within the adhesive or failed at the adhesive/enamel interface. The results of this study suggest that office bleaching with hydrogen peroxide does not adversely affect the bond strengths of brackets bonded immediately after bleaching or 30 days after bleaching, even though bleaching can result in differences in the failure site.

Acid Etching, Dental↗

Effects of fast halogen and plasma arc curing lights on the surface hardness of orthodontic adhesives for lingual retainers.

The aims of this study were to (1) identify the optimum cure times of 2 different lingual retainer adhesives with a conventional halogen, a fast halogen, and a plasma arc light by measuring Vickers surface hardness, and (2) determine whether different lights produce similar surface hardness values for the same adhesive resin material. The investigated plasma arc curing unit was the PowerPac (American Dental Technologies, Corpus Christi, Tex), and the fast halogen unit was the Optilux 501 (Kerr, Orange, Calif). A conventional curing unit, the Ortholux XT (3M Dental Products, St. Paul, Minn) was used as the control. Two orthodontic lingual retainer adhesives were used: Transbond Lingual Retainer (3M Unitek, Monrovia, Calif) and Light Cure Retainer (Reliance Orthodontic Products, Itasca, Ill). Concise (3M Dental Products) and diluted Concise were used as controls. Transbond Lingual Retainer was polymerized by the PowerPac light in 6 seconds, by the Optilux in 10 seconds, and by the conventional halogen light in 20 seconds. The minimum curing times for Light Cure Retainer adhesive were 15 seconds for PowerPac, 10 seconds for Optilux, and 40 seconds for conventional halogen. Surface hardness values for each resin did not differ significantly with different curing units. However, different adhesives demonstrated significantly different surface hardness values. Final Vickers surface hardness values (averaged across curing units) of Transbond Lingual Retainer, Concise, diluted Concise, and Light Cure Retainer were 62.8, 52.4, 46.0, and 40.4, respectively. Plasma arc or fast halogen units polymerize resin composite adhesive in much shorter times than do conventional curing units, without a significant loss in surface hardness. Therefore, these units are suggested for clinical use to save chairside time.

Adhesives↗

Reproducibility of natural head position measured with an inclinometer.

Sagittal (pitch) and transversal (roll) natural head position (NHP) was measured once in 20 subjects, 18 to 24 years of age, with an inclinometer; the measurements were repeated 2 years later. The method error (reproducibility) after 2 years was 1.1 degrees for sagittal and transversal measurements. The mean change in NHP measurement was -0.3 degrees for both measurements, and the variance was 1.21 degrees (= 1.1(2)).

Adolescent↗

Laser etching of enamel for direct bonding with an Er,Cr:YSGG hydrokinetic laser system.

Irradiation of enamel with laser energy changes the physical and chemical characteristics of the enamel surface, and these alterations hold promise for the conditioning of enamel for bonding procedures. This laboratory study examined the influence of laser irradiation of enamel at 2 different power settings with an erbium, chromium: yttrium, scandium, gallium, garnet (Er,Cr:YSGG) hydrokinetic laser system (Millennium System, Biolase Technology, Inc; San Clemente, Calif) on the shear bond strength of orthodontic appliances and compared these with that of acid-etching. The prepared surfaces of 40 noncarious, intact, extracted premolars were exposed to laser energy: 20 teeth at 2-W setting (5.6 J/cm(2)) and 20 teeth at 1-W setting (2.7 J/cm(2)) of the commercial laser unit. Twenty teeth were etched with 37% orthophosphoric acid. Brackets were bonded with an orthodontic no-mix adhesive, and shear bond strength was determined with a universal testing machine. Data were analyzed with Kruskal-Wallis and Mann-Whitney U tests. Etched and restored surfaces of an acid-etched tooth and a 2-W laser-irradiated tooth were examined with scanning electron microscopy (SEM). Laser treatment under 2 W resulted in bond strengths of 7.11 +/- 4.56 megapascals (MPa), which was not significantly different from that of acid etching (8.23 +/- 2.30 MPa). Laser irradiation at 1 W resulted in bond strengths of 5.64 +/- 3.19 MPa, which was significantly different from that of acid etching (P <.05). However, large SD and coefficient of variation values of both laser groups made reliability of this method as an enamel conditioner questionable. Scanning electron microscopy studies of the restored irradiated surfaces showed good surface characteristics, whereas the lased surface was still more irregular than the restored acid-etched sample. Although laser devices are effectively used in some other areas of dentistry, enamel conditioning with an Er,Cr:YSGG laser cannot be considered a successful alternative to the conventional methods of increasing bond strengths to enamel.

Acid Etching, Dental↗