PubMed Health⌕ Search

Biomedical subjects

Serge De Ridder

Publications and source records attributed to Serge De Ridder.

2 recordsLinked to original sources

Percutaneous transcatheter closure of atrial septal defects: initial single-centre experience and follow-up results. Initial experience with three-dimensional echocardiography.

OBJECTIVE: Registry to report our single-centre experience in closing defects of the atrial septum. METHODS: Between 1996 and 2001, transcatheter device closure of significant atrial septal defects was performed in 32 adults (mean age 45.1 years, range from 15 to 76 years), using different device types. Six patients had a patent foramen ovale (PFO) and 26 patients had a secundum atrial septal defect (ASD II). Defects were selected by means of two-dimensional transoesophageal echocardiography (2D TOE). For 12 defects additional three-dimensional transoesophageal echocardiography (3D TOE) was performed. RESULTS: Mean balloon-stretched diameter was 19.3 mm (range from 11 to 24 mm). A device was successfully placed in all PFO patients (100%) without complications at follow-up. Successful immediate device placement occurred in 24 out of 26 ASD patients. Two immediate placement failures, 1 device embolisation and 1 device non-fixation, occurred and required urgent surgery. There was 1 patient with pericardial effusion after the intervention, requiring pericardiocentesis. Three late placement failures occurred: 2 device embolisations and 1 device dislocation. Clinical success after 3 to 6 months follow-up, defined as the absence of shunt or small shunt, was achieved in all 6 PFO patients and in 21 out of 23 ASD patients (1 device embolisation, requiring surgery, occurred before follow-up was completed). Two patients with significant shunt, 1 late device dislocation and 1 late device embolisation, underwent elective surgery. For patient selection, 3D TOE proved useful in the evaluation of large and/or complex defects. CONCLUSION: Transcatheter device closure of carefully selected atrial septal defects is an alternative to surgery. Although the results are promising, surgical back-up is often needed.

Adolescent↗

Internal cardioversion: a worthwhile alternative after failed external cardioversion in obese patients.

Transthoracic external cardioversion is, if carried out properly, a highly effective cardioversion modality for most patients with atrial fibrillation. Failure to return to sinus rhythm (even for one or two beats) can be related to high transthoracic impedance. Internal cardioversion may offer a safe and worthwhile alternative for these patients, in need of sinus rhythm. This technique, mostly requiring only mild sedation, is actually performed in many electrophysiology centers. Because recurrence rates of atrial fibrillation seem to be the same for both methods, this invasive technique should be considered in patients with a rather low chance of atrial fibrillation recurrences. We present a case report of an extremely obese woman, resistant to external cardioversion. She successfully underwent internal low-energy cardioversion.

Adult↗