PubMed Health⌕ Search

Biomedical subjects

Sergio L Pinski

Publications and source records attributed to Sergio L Pinski.

11 recordsLinked to original sources

Spondyloarthropathy-associated aortitis and massive thickening of the aortic-mitral curtain: diagnosis by echocardiography.

Cardiac involvement in reactive arthritis is well-recognized, and usually results in aortic regurgitation, proximal aortitis, and conduction system abnormalities. Aortitis is usually recognized in conjunction with aortic regurgitation, but can be diagnosed in isolation as aortic root thickening and subaortic fibrous ridging. We report a case of spondyloarthropathy-associated aortitis diagnosed by transesophageal echocardiography. The case illustrates the aortic root pathology and highlights the unique morphologic echocardiographic feature of this condition, prominent thickening of the aortic-mitral curtain.

Aorta↗

Twelve-lead electrocardiogram: the advantages of an orderly frontal lead display including lead -aVR.

BACKGROUND: It is possible that efforts in ECG review by both young experienced clinicians are currently discouraged-and risk to be completely dismissed-by the conventional (ie, disorderly) display of the frontal plane leads, with lead aVR at -150 degrees. METHODS: We reviewed studies on the usefulness of leads aVR and -aVR as well as on the history of the frontal leads in electrocardiography. RESULTS: Lead aVR and particularly, lead -aVR, provide useful information when systematically analyzed. In addition, if lead -aVR is examined in its anatomically logical sequence, ie, aVL, I, -aVR, II, aVF, and III, the frontal plane of the 12-lead ECG is more easily understood. This "panoramic" or "orderly" display is in common use in countries such as Sweden, but it is rarely seen in the United States. CONCLUSIONS: ECG interpretation would be enhanced by displaying the limb leads in an orderly arrangement that starts with lead aVL and ends with lead III, and many ECG changes would be ideally displayed by a lead -aVR at 30 degrees.

Arrhythmias, Cardiac↗

What is the minimal pacing rate that prevents torsades de pointes? Insights from patients with permanent pacemakers.

In the acquired long QT syndrome, torsades de pointes (TP) is invariably preceded by pauses or bradycardia. Thus, it has been proposed that out-of-hospital initiation of drugs that prolong repolarization should be safe in patients with permanent pacemakers. However, a minimal protective pacing rate has not been identified. The authors reviewed published reports of acquired TP in patients with permanent pacing. Those providing documentation of tachycardia onset and pacemaker programming were included in the analysis. Events occurring < or = 1 month after AV nodal ablation were excluded. Eighteen cases were identified (age 74 +/- 5; 10 women). QT prolonging drugs were present in 15 patients (quinidine 5, sotalol 3, disopyramide 3, amytriptiline, chloroquine, cisapride + haloperidol, and monopride + flecainide 1 each). Hypokalemia was present in eight patients. At the time of TP, the programmed lower rate was 63 +/- 13 beats/min. However, the effective pacing rate was lower (55 +/- 11 beats/min) due to invocation of pause-promoting features (hysteresis [4 patients]; + PVARP extension on PVC [1 patient]) or ventricular oversensing (2 patients). No patient developed TP with an effective pacing rate > 70 beats/min. TP is possible in the presence of a functional permanent pacemaker. Programmed lower rates < or = 70 beats/min are not protective. At programmed lower rates > 70 beats/min, TP may occur only when facilitated by programmable pause-promoting features or oversensing. It remains to be seen if rate smoothing algorithms can prevent TP when the baseline rate is programmed < or = 70 beats/min.

Aged↗

Cardiac pacing: the state of the art.

Permanent cardiac pacing remains the only effective treatment for chronic, symptomatic bradycardia. In recent years, the role of implantable pacing devices has expanded substantially. At the beginning of the 21st century, exciting developments in technology seem to happen at an exponential rate. Major advances have extended the use of pacing beyond the arrhythmia horizon. Such developments include dual-chamber pacers, rate-response algorithms, improved functionality of implantable cardioverter defibrillators, combinations of sensors for optimum physiological response, and advances in lead placement and extraction. Cardiac pacing is poised to help millions of patients worldwide to live better electrically. We review pacing studies of sick-sinus syndrome, neurocardiogenic syncope, hypertrophic obstructive cardiomyopathy, and cardiac resynchronisation therapy, which are common or controversial indications for cardiac pacing. We also look at the benefits and complications of implantation in specific arrhythmias, suitability of different pacing modes, and the role of permanent pacing in the management of patients with heart failure.

Arrhythmias, Cardiac↗