Trabecular architecture of lumbar vertebral pedicle.

STUDY DESIGN: Investigation on architecture of lumbar pedicle. OBJECTIVE: To determine morphological properties of pedicular cancellous bone. SUMMARY OF BACKGROUND DATA: Many researchers have been stimulated to study trabecular architecture by improvements in stereological technology. Although the structure of vertebral cancellous bone has been well studied in the literature, no information is available about the architecture of pedicular cancellous bone. METHODS: Eight cadaveric L3 lumbar vertebrae were harvested. After collecting the bone mineral density (BMD) data on the vertebrae, pedicle isthmuses were removed from the vertebral bodies using a reciprocal hand saw. The BMD measurements were done on the dissected pedicle isthmus specimens. All the specimens were then analyzed using a micro-computed tomography unit. Morphologic parameters of trabecular bone were calculated. RESULTS: Bone volume was found as 0.209 +/- 0.046, whereas Tb.Th, Tb.Sp, and Tb.N were found to be 0.201 +/- 0.035 mm, 0.930 +/- 0.123 mm, and 1.098 +/- 0.136 mm(-1), respectively. Connectivity density and structure model index were observed to be 3.135 +/- 0.918 mm(-3), 0.37, whereas degree of anisotropy value was 1.241 +/- 0.093. Vertebral BMD could explain 63% of variance in bone density of a pedicle isthmus. CONCLUSIONS: The structure of the pedicular cancellous bone is somewhat different from that of vertebral body. The trabecular architecture within the pedicle isthmus is isotropic and plate-like. The thickness and number of the trabeculae were greater than those of vertebral trabeculae. Decrease in the bone volume with age is mainly by thinning of the trabeculae and increasing in trabecular spacing, but not by loss of mass.

Adult↗

Biomechanical comparison of transarticular facet screws to lateral mass plates in two-level instrumentations of the cervical spine.

STUDY DESIGN: In vitro biomechanical comparison of transarticular facet screws to lateral mass plates in two level instrumentations of the cervical spine. OBJECTIVE: Lateral mass plates are costly, and screw placement is difficult. Facet screws have never been tested as an alternative in the cervical spine. This biomechanical study compared cervical transarticular facet screws to lateral mass plates in two-level instrumentations of human cadaveric cervical spines. SUMMARY OF BACKGROUND DATA: Translaminar facet screws have been shown to have similar biomechanical performance to pedicle screw fixation in the lumbar spine, especially in flexion. They have proven to be fast, safe, and effective, with authors reporting 94% to 100% fusion rates in single-level lumbar fusions. However, a biomechanical comparison of transarticular facet screws to lateral mass plates in cervical spine instrumentations has not been reported. METHODS: Thirteen human cadaveric cervical motion segments (C2-C4, C5-C7) were tested before and after instrumentation, with either transarticular facet screws or lateral mass plates, in flexion, extension, lateral bending, and torsion. Specimens were subjected to six cycles under a load of 2 Nm. RESULTS: Both fixation systems significantly reduced range of motion (ROM) and increased stiffness compared with the intact state in flexion, extension, lateral bending, and torsion. There were also no significant differences between the facet screws and plates in any of the four directions. To compare the two systems, ROM of each was analyzed relative to the uninstrumented state. Flexion was 0.26 (or 26% of the intact state) for the transarticular facet screws versus 0.20 for the lateral mass plates (P = 0.34), extension was 0.10 versus 0.07 (P = 0.43), lateral bending was 0.17 versus 0.15 (P = 0.52), and torque was 0.25 versus 0.38 (P = 0.12). Load to failure testing failed to indicate any differences between the two methods of fixation because all the specimens failed elsewhere. CONCLUSION: This study proves that transarticular facet screws and lateral mass plates are equivalent in two-level instrumentations of the cervical spine. This is the first biomechanical study to test transarticular facet screws in this context.

Aged↗

Stress relaxation of bone significantly affects the pull-out behavior of pedicle screws.

The initial fixation strength of pedicle screws is commonly tested using a standard pull-out test with load applied at a constant rate. This method overlooks the cyclic nature of in situ loading responsible for clinical failure. This study was undertaken to determine the effects of stress relaxation properties at the bone-screw interface on screw fixation strength. Pedicle screws were inserted into calf lumbar vertebrae using a paired testing array. After embedding and mounting in a custom fixture, axial pull-out tests were performed at the rates of 1, 5, and 25 mm/min. For each vertebra, one screw was pulled at a continuous rate. The other screw was pulled at increments of 0.5 mm, at the same rate, with 1000 s pause between increments. Peak load, energy-to-failure, displacement-to-failure, and stiffness were calculated for each screw pull-out test. Two-way ANOVA showed that the standard pull-out method yielded significantly higher peak loads (p < 0.05) at faster pull-out rates and higher stiffnesses (p < 0.05) at all rates compared to the stress relaxation pull-out protocol. These results suggest that the stress relaxation properties of bone significantly affect the pull-out behavior of pedicle screws, reducing the peak load and stiffness values observed during testing. This mode of testing may provide a better biomechanical model of screw pull-out failure and a more accurate estimate of initial fixation strength.

Animals↗

A biomechanical comparison of facet screw fixation and pedicle screw fixation: effects of short-term and long-term repetitive cycling.

STUDY DESIGN: A biomechanical study was conducted to assess the stabilization performance of transfacet pedicle screw fixation. OBJECTIVE: To compare the biomechanical effects of short-term and long-term cyclic loading on lumbar motion segments instrumented with either a pedicle screw or a transfacet pedicle screw construct. SUMMARY OF BACKGROUND DATA: Facet screw fixation is an alternative to pedicle screw fixation that permits the use of a minimally invasive strategy. It is not known whether facet screw fixation can provide stability equivalent to pedicle screw fixation during cyclical loading. Therefore, transfacet pedicle screw fixation and standard pedicle screw fixation techniques were compared biomechanically. METHODS: Lumbar motion segments were tested under short-term and long-term cyclic loading conditions. For the short-term phase, specimens were tested intact for six cycles (to 400 N or 4 Nm) in compression, flexion, extension, lateral bending, and torsion. The specimens then were instrumented with bilateral semicircular interbody spacers and pedicle screw instrumentation or transfacet pedicle screws, and the testing sequence was repeated. For the long-term phase, 12 specimens were instrumented in a similar manner and loaded to 6 Nm of flexion bending for 180,000 cycles. RESULTS: For the short-term phase, both fixation systems had significantly greater stiffness and reduced range of motion, as compared with the intact state. No differences were observed between the fixation systems except in flexion, wherein transfacet pedicle screw specimens were significantly stiffer than traditional pedicle screw specimens. For the long-term phase, the stiffness and range of motion did not significantly increase or decrease over repetitive cycling of the instrumented specimens. Furthermore, no significant difference between the fixation systems was observed. CONCLUSIONS: The stability provided by both transfacet pedicle screw fixation and traditional pedicle screw fixation was not compromised after repetitive cycling. In this model, transfacet pedicle screw fixation appears equivalent biomechanically to traditional pedicle screw fixation.

Biocompatible Materials↗

Pedicle screw fixation strength: pullout versus insertional torque.

BACKGROUND CONTEXT: Researchers studying early pedicle screw designs have suggested that pullout strength and insertional torque are correlated. For surgeons using pedicle screws, insertional torque is widely believed to be a good predictor of pullout strength and initial stability of the screw and construct. How appropriate is this assumption when applied to new screw and thread designs? PURPOSE: This study investigated the correlation between insertional torque and pullout strength of three different pedicle screw designs, with different insertional torque characteristics. We hypothesized that a significant increase in insertional torque would indicate a commensurate increase in pullout strength. STUDY DESIGN: Biomechanical analysis of instrumented vertebral specimens. METHODS: Calf lumbar vertebra were prepared and instrumented with one of three pedicle screws. Pilot hole preparation was standardized and coaxial orientation was confirmed by direct inspection. Screws did not penetrate the pedicle cortex or abut or penetrate the anterior vertebral cortex. Any specimen with pedicle wall breach was discarded. The pedicles were instrumented with one of three screws: 1) 7.5 x 40 mm conical, asymmetric progressive thread (Xia; Stryker Spine, Allendale, NJ), 2) 7.5 x 40 mm conical with traditional V-shaped thread (Osteonics, Stryker Spine, Allendale, NJ)) or 3) 6.5 x 40 mm cylindrical with V thread (Osteonics, cylindrical). Paired testing allowed individual screws to be directly compared with a contralateral "control." Insertional torque and peak torque values were recorded for each rotation up to full insertion. Pullout testing was conducted at a rate of 1 mm/minute. Load-displacement data were recorded at 20 Hz. Stiffness was considered the slope of the most linear part of the curve before the yield point. RESULTS: Peak loads for 7.5 conical Xia screws measured 1,783+/-589.1 N compared with 1,943.0+/-625.8 N for 7.5 conical Osteonics screws and 1,641.0+/-356.7 N for 6.5 cylindrical Osteonics screws. The peak insertional torque values were 6.7+/-1.9 Nm (158% greater than control), 4.5+/-1.1 Nm (73% greater than control) and 2.6+/-0.7 Nm, respectively. Insertional torques for Xia screws were significantly greater than conical (p=.001) and cylindrical Osteonics screws (p<.0001), and insertional torques for Osteonics conical screws were significantly greater than those of cylindrical screws (p<.0001). Although pullout loads for the conical Osteonics screws were consistently higher than either the Xia or Osteonics cylindrical screws, the differences were not significant (p>.05). There was no significant correlation between pullout strength and insertional torque (p>.05). CONCLUSIONS: This unexpected result is best explained by the progressively narrowing flutes of the Xia screw, which compact the trabeculae into a smaller volume as the screw nears full insertion. The trapezoidal threads also increase contact with the cortical surface area and compress trabeculae toward the cortex, thus creating greater friction and higher torque values. This increase in torque did not translate into a commensurate increase in pullout strength, where trabeculae fail in shear.

Animals↗