PubMed Health⌕ Search

Biomedical subjects

Serpil Ozkara

Publications and source records attributed to Serpil Ozkara.

4 recordsLinked to original sources

Pathogenic antibody removal using magnetically stabilized fluidized bed.

Magnetic poly(2-hydroxyethyl methacrylate) (mPHEMA) beads were used in the removal of anti-dsDNA antibodies from systemic lupus erythematosus (SLE) patient plasma in a magnetically stabilized fluidized bed. mPHEMA beads, in the size range of 80-120 microm, were produced by suspension technique. Then, DNA was immobilized onto mPHEMA beads by carbodiimide activation. Magnetic beads were contacted with blood in in vitro systems. Loss of blood cells and clotting times were followed. mPHEMA beads were characterized by scanning electron microscopy (SEM). Important results obtained in this study are as follows: the mPHEMA beads have a spherical shape and porous structure. Loss of cells in the blood contacting with mPHEMA/DNA was negligible. The anti-dsDNA adsorption capacity decreased significantly with the increase of the flow-rate. With increasing anti-dsDNA antibody concentration, the amount of antibody adsorbed per unit mass increased, then reached saturation. Maximum anti-dsDNA antibody adsorption capacity was found to be 97.8 mg/g. Pathogenic antibody molecules could be repeatedly adsorbed and desorbed with these magnetic beads without noticeable loss in their antibody adsorption capacity. Because of the good blood-compatibility, mPHEMA is hopeful for the treatment of SLE by magnetically stabilized fluidized bed systems in the future.

Antibodies, Antinuclear↗

Novel metal-chelate affinity adsorbent for purification of immunoglobulin-G from human plasma.

Metal-chelating ligand and/or comonomer 2-methacrylolyamidohistidine (MAH) was synthesized by using methacryloyl chloride and L-histidine methyl ester. MAH was characterized by NMR and FTIR. Spherical beads with an average diameter of 75-125 microm were produced by suspension polymerization of methylmethacrylate (MMA) and MAH carried out in an aqueous dispersion medium. Poly(MMA-MAH) beads had a specific surface area of 37.5 m(2)/g. Poly(MMA-MAH) beads were characterized by water uptake studies, FTIR, SEM and elemental analysis. Elemental analysis of MAH for nitrogen was estimated as 34.7 microM/g of polymer. Then, Cu(2+) ions were chelated on the beads. Cu(2+)-chelated beads with a swelling ratio of 38% were used in the adsorption of human-immunoglobulin G (HIgG) from both aqueous solutions and human plasma. The maximum adsorption capacities of the Cu(2+)-chelated beads were found to be 12.2 mg/g at pH 6.5 in phosphate buffer and 15.7 mg/g at pH 7.0 in MOPS. Higher adsorption value was obtained from human plasma (up to 54.3 mg/g) with a purity of 90.7%. The metal-chelate affinity beads allowed one-step separation of HIgG from human plasma. The adsorption-desorption cycle was repeated 10 times using the same beads without noticeable loss in their HIgG adsorption capacity.

Adsorption↗

N-methacryloly-(L)-histidinemethylester carrying a pseudospecific affinity sorbent for immunoglobulin-G isolation from human plasma in a column system.

N-methacryloly-(L)-histidinemethylester (MAH) as a pseudospecific ligand was synthesized by using methacryloyl chloride and histidine. Spherical beads with an average size of 63-75 microm were obtained by suspension polymerization of ethylene glycol dimethacrylate (EGDMA), 2-hydroxyethyl methacrylate (HEMA) and MAH conducted in an aqueous dispersion medium. The specific surface area of the beads was found to be 18.3 m2/g. Poly(EGDMA-HEMA-MAH) beads were used in the separation of immunoglobulin-G (HIgG) from aqueous solutions and/or human plasma in a packed-bed column system. HIgG adsorption capacity of the beads decreased with an increase in the flow-rate of plasma. The maximum HIgG adsorption on the poly(EGDMA-HEMA-MAH) sorbents was observed at pH 7.4. HIgG adsorption onto the poly(EGDMA-HEMA) sorbents was negligible. Higher adsorption values (up to 135 mg/g) were obtained when the poly(EGDMA-HEMA-MAH) sorbents were used from aqueous solutions. HIgG adsorption increased with decreasing temperature and the maximum adsorption achieved at 4 degrees C. MAH incorporation significantly affected HIgG adsorption capacity (135 mg/g). Higher amounts of HIgG were adsorbed from human plasma (up to 165 mg/g). Adsorption capacities of other blood proteins were obtained as 8.7 mg/g for fibrinogen and 14.6 mg/g for albumin. The total protein adsorption was determined as 191 mg/g. The pseudospecific affinity beads allowed one-step separation of HIgG from human plasma. HIgG molecules could be repeatedly adsorbed and desorbed with these sorbents without noticeable loss in their HIgG adsorption capacity.

Adsorption↗

A novel magnetic adsorbent for immunoglobulin-g purification in a magnetically stabilized fluidized bed.

A novel magnetic poly(ethylene glycol dimethacrylate-N-methacryloly-L-histidinemethylester) [m-poly(EGDMA-(MAH)] support was prepared for purification of immunoglobulin G (IgG) in a magnetically stabilized fluidized bed by suspension polymerization. Elemental analysis of the magnetic beads for nitrogen was estimated as 70 micromol MAH/g polymer. Magnetic poly(EGDMA-MAH) beads were used in the separation of immunoglobulin-G (IgG) from aqueous solutions and/or human plasma in a magnetically stabilized fluidized bed system. IgG adsorption capacity of the beads decreased with an increase in the flow rate. The maximum IgG adsorption was observed at pH 6.0 for MES buffer. IgG adsorption onto the m-poly(EGDMA) was negligible. Higher adsorption values (up to 262 mg/g) were obtained in which the m-poly(EGDMA-MAH) sorbents were used from aqueous solutions. Higher amounts of IgG were adsorbed from human plasma (up to 320 mg/g) with a purity of 87%. IgG molecules could be repeatedly adsorbed and desorbed with these sorbents without noticeable loss in their IgG adsorption capacity.

Adsorption↗