PubMed Health⌕ Search

Biomedical subjects

Seth Worley

Publications and source records attributed to Seth Worley.

2 recordsLinked to original sources

Nonexcitatory, cardiac contractility modulation electrical impulses: feasibility study for advanced heart failure in patients with normal QRS duration.

BACKGROUND: Cardiac contractility modulation signals are associated with acutely improved hemodynamics, but chronic clinical impact is not defined. OBJECTIVES: The purpose of this randomized, double-blind, pilot study was to determine the feasibility of safely and effectively delivering cardiac contractility modulation signals in patients with heart failure. METHODS: Forty-nine subjects with ejection fraction <35%, normal QRS duration (105 +/- 15 ms), and New York Heart Association (NYHA) class III or IV heart failure despite medical therapy received a cardiac contractility modulation pulse generator. Patients were randomized to have their devices programmed to deliver cardiac contractility modulation signals (n = 25, treatment group) or to remain off (n = 24, control group) for 6 months. Evaluations included NYHA class, 6-minute walk, cardiopulmonary stress test, Minnesota Living with Heart Failure Questionnaire, and Holter monitoring. RESULTS: Although most baseline features were balanced between groups, ejection fraction (31.4% +/- 7.4% vs 24.9% +/- 6.5%, P = .003), end-diastolic dimension (52.1 +/- 21.4 mm vs 62.5 +/- 6.2 mm, P = .01), peak VO(2) (16.0 +/- 2.9 mL O(2)/kg/min vs 14.3 +/- 2.8 mL O(2)/kg/min, P = .02), and anaerobic threshold (12.3 +/- 2.5 mL O(2)/kg/min vs 10.6 +/- 2.4 mL O(2)/kg/min, P = .01) were worse in the treatment group than in the control group. Nevertheless, one death occurred in the control group, and more patients in the treatment group were free of hospitalization for any cause at 6 months (84% vs 62%). No change in ectopy was observed. Compared with baseline, 6-minute walk (13.4 m), peak VO(2) (0.2 mL O(2)/kg/min), and anaerobic threshold (0.8 mL O(2)/kg/min) increased more in the treatment group than in control. None of these differences were statistically significant (small sample size). NYHA and Minnesota Living with Heart Failure Questionnaire changed similarly in the two groups. CONCLUSION: Despite a sicker population in the treatment group, no specific safety concerns emerged with chronic cardiac contractility modulation signal administration. Further study is required to definitively define the safety and efficacy of cardiac contractility modulation signals.

Aged↗

Bachmann's bundle versus right atrial appendage capture.

The tissue in the high intraatrial septum in the region of Bachmann's Bundle (BB) exhibits electrophysiological properties that differ from the right atrial appendage (RAA). As BB pacing emerges as an alternative to RAA pacing, the feasibility of using automatic capture recognition technology in this location should be examined. At implant, active-fixation leads were consecutively placed in the RAA, then the BB in 18 patients (55.5% men, mean age 77.1 +/- 9.1). There was no significant difference between BB and RAA in the average capture threshold (1.12 vs 1.77 V, P = 0.09), sensing threshold (3.85 vs 3.69 mV, P = 0.84), impedance (508 vs 529 Ohms, P = 0.64), evoked response (1.78 vs 1.67 mV, P = 0.83), and polarization (0.41 vs 0.46 mV, P = 0.84) between. The difference in tissue characteristics was not associated with a different evoked response measured by the ventricular capture recognition algorithm. Based on the analogous evoked response and polarization values, capture recognition technology designed for the atrium will most likely be applicable at both pacing sites.

Aged↗