Clinical value of manual fusion of PET and CT images in patients with suspected recurrent colorectal cancer.

OBJECTIVE: The purpose of this study was to compare the diagnostic performance of manually fused PET images obtained using 18F-FDG and CT images with that of CT alone, PET alone, and conventional side-by-side review of PET images and CT images (hereafter referred to as "PET + CT") in patients with suspected recurrent colorectal cancer. MATERIALS AND METHODS: Ethics committee approval and informed consent were obtained. Sixty-three patients with suspected recurrent colorectal cancer underwent whole-body 18F-FDG PET followed by diagnostic CT. The acquired PET and CT images were merged on a workstation on a pixel-to-pixel basis. CT, PET, PET + CT, and fused images were evaluated separately in terms of the presence or absence of recurrence, new metastases, or both using a 5-point grading scale (0 = definitely negative, 1 = probably negative, 2 = equivocal, 3 = probably positive, and 4 = definitely positive). Lesions determined to be grade 3 or 4 were considered positive, and diagnostic accuracy and certainty were evaluated with statistical analysis using the chi-square test for independence. RESULTS: Of 119 pathologically or clinically confirmed lesions in 36 patients, evaluation of CT, PET, PET + CT, and fused images resulted in the detection of 75 (63%), 84 (71%), 91 (76%), and 111 (93%) lesions, respectively (p < 0.01) with the number of grade 4 lesions detected being 59 (50%), 72 (61%), 84 (71%), and 108 (91%), respectively (p < 0.01). Overall, the diagnostic accuracy of CT, PET, PET + CT, and fused images according to patient were 78%, 79%, 84%, and 92%, respectively (p = 0.13). CONCLUSION: Interpreting fused images provided more accurate diagnoses than interpreting CT, PET, or PET + CT images. This method of manually fusing separately obtained PET and CT images increased the diagnostic certainty for detecting colorectal cancer recurrence and decreased the number of equivocal cases.

Adult↗

Comparison of the diagnostic performance of FDG-PET and VBM-MRI in very mild Alzheimer's disease.

PURPOSE: The aim of this study was to compare the diagnostic performance of( 18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET) and voxel-based morphometry (VBM) on magnetic resonance imaging (MRI) in the same group of patients with very mild Alzheimer's disease (AD). METHODS: Thirty patients with very mild AD (age 67.0+/-5.8 years; MMSE score 25.5+/-1.2, range 24-28), 32 patients with mild AD (age 67.0+/-4.5 years, MMSE score 22.1+/-0.8, range 21-23) and 60 age- and sex-matched normal volunteers underwent both FDG-PET and three-dimensional spoiled gradient echo MRI. Statistical parametric mapping was used to conduct voxel by voxel analysis and Z score mapping. First, the region of interest (ROI) maps of significant reductions in glucose metabolism and grey matter density in the mild AD patients were defined. Secondly, analysis of receiver operating characteristic (ROC) curves for Z scores in the ROI maps discriminating very mild AD patients and normal controls was performed. RESULTS: In mild AD patients, FDG-PET indicated significant reductions in glucose metabolism in the bilateral posterior cingulate gyri and the right parietotemporal area, while VBM analysis showed a significant decrease in grey matter volume density in the bilateral amygdala/hippocampus complex, compared with the normal control group. ROC analysis showed that in very mild AD patients the accuracy of FDG-PET diagnosis was 89% and that of VBM-MRI diagnosis was 83%. The accuracy of the combination of FDG-PET and VBM-MRI diagnosis was 94%. CONCLUSION: In very mild AD, both FDG-PET and VBM-MRI had high accuracy for diagnosis, but FDG-PET showed slightly higher accuracy than VBM-MRI. Combination of the two techniques will yield a higher diagnostic accuracy in very mild AD by making full use of functional and morphological images.

Aged↗

Fully automatic diagnostic system for early- and late-onset mild Alzheimer's disease using FDG PET and 3D-SSP.

PURPOSE: The purpose of this study was to design a fully automatic computer-assisted diagnostic system for early- and late-onset mild Alzheimer's disease (AD). METHODS: Glucose metabolic images were obtained from mild AD patients and normal controls using positron emission tomography (PET) and( 18)F-fluorodeoxyglucose (FDG). Two groups of 20 mild AD patients with different ages of onset were examined. A fully automatic diagnostic system using the statistical brain mapping method was established from the early-onset (EO) and late-onset (LO) groups, with mean ages of 59.1 and 70.9 years and mean MMSE scores of 23.3 and 22.8, respectively. Aged-matched normal subjects were used as controls. We compared the diagnostic performance of visual inspection of conventional axial FDG PET images by experts and beginners with that of our fully automatic diagnostic system in another 15 EO and 15 LO AD patients (mean age 58.4 and 71.7, mean MMSE 23.6 and 23.1, respectively) and 30 age-matched normal controls. A receiver operating characteristic (ROC) analysis was performed to compare data. RESULTS: The diagnostic performance of the automatic diagnostic system was comparable with that of visual inspection by experts. The area under the ROC curve for the automatic diagnostic system was 0.967 for EO AD patients and 0.878 for LO AD patients. The mean area under the ROC curve for visual inspection by experts was 0.863 and 0.881 for the EO and LO AD patients, respectively. The mean area under the ROC curve for visual inspection by beginners was 0.828 and 0.717, respectively. CONCLUSION: The fully automatic diagnostic system for EO and LO AD was able to perform at a similar diagnostic level to visual inspection of conventional axial images by experts.

Age of Onset↗

Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 standard.

UNLABELLED: The SET-3000 G/X (clinical tomograph with high resolution and a large axial field of view) is a 3-dimensional (3D) (only) dedicated PET camera with germanium oxyorthosilicate (GSO) and bismuth germanate (BGO) scintillators. The main characteristic of the SET-3000 G/X PET scanner is 3D continuous-emission and spiral-transmission (CEST) scanning, yielding a reduction in whole-body scan time. We evaluated the physical performance of the SET-3000 G/X PET scanner with the National Electrical Manufacturers Association (NEMA) NU 2-2001 standard. METHODS: A GSO 3D emission scanner is combined with a BGO transmission scanner separated axially by a lead shield. In the GSO scanner, small and thick scintillators (2.45 x 5.1 x 30 mm(3)) are arranged in small blocks (23.1 x 52 mm) to achieve high resolution and a high counting rate. The detector ring has a large solid angle with a diameter of 664 mm and an axial coverage of 260 mm (50 rings). The transmission scanner consists of BGO block detectors with a diameter of 798 mm and an axial width of 23.1 mm and is equipped with a rotating (137)Cs point source of 740 MBq and a tungsten collimator. The low- and high-energy thresholds are set to 400 and 700 keV, respectively, in the emission system. The coincidence time window is set to 6 ns. In CEST acquisition, the patient couch moves continuously through the emission and transmission scanners in a 1-way motion. Emission coincidence data are acquired in the histogram mode with on-the-fly Fourier rebinning, and transmission single data are acquired with emission contamination correction. RESULTS: With the NEMA NU 2-2001 standard, the main performance results were as follows: the average (radial and tangential) transverse and axial spatial resolutions (full width at half maximum) at 1 cm and at 10 cm off axis were 3.49 and 5.04 mm and 4.48 and 5.40 mm, respectively; the average sensitivity for the 2 radial positions (0 and 10 cm) was 20.71 cps/kBq; the scatter fraction was 50%; the peak noise equivalent count rate was 62.3 kcps at 9.8 kBq/mL; and the peak random rate was 542.1 kcps at 37.6 kBq/mL. CONCLUSION: The new integrated SET-3000 G/X PET scanner has good overall performance, including high resolution and sensitivity, and has the potential of reducing whole-body acquisition time to less than 10 min while improving small-lesion detectability with a low radiation dose.

Equipment Design↗

An intra-operative positron probe with background rejection capability for FDG-guided surgery.

For radio-guided surgery on tumors using F-18-FDG, detection of annihilation gamma photons emanating from other parts of the body produces background radiation counts and limits its use in clinical situations. To overcome this limitation, we have developed an intra-operative positron probe with background-rejection capability. The positron probe uses a phoswich detector composed of a plastic scintillator and a bismuth germinate (BGO). A positron from a positron emitter such as F-18 is detected by the plastic scintillator and emits annihilation photons. The BGO detects one of the annihilation photons while a photo-multiplier tube (PMT) detects scintillation photons from both scintillators. The decay time differences of these two scintillators are used to distinguish whether the event is a true event where a positron and a following annihilation photon are detected simultaneously, or a background event. In this configuration, only positrons can be selectively detected, even in an environment of high background gamma photon flux. Spatial resolution was 11-mm full width at half maximum (FWHM) 5 mm from the detector surface. Measured sensitivity for the F-18 point source was 2.6 cps/kBq 5 mm from the detector surface. The background count rate was less than 0.5 cps for a 20-cm diameter cylindrical phantom containing 37 MBq of F-18 solution measured on the phantom surface, while the positron count rate was almost linear over a range of approximately 6 kcps. These results indicate that our developed intra-operative positron probe is valuable for radio-guided surgery on tumors using F-18-FDG in a high flux of background annihilation gamma photons.

Background Radiation↗

Accuracy of image fusion using a fixation device for whole-body cancer imaging.

OBJECTIVE: The purpose of this study was to evaluate the clinical feasibility of a simple image fusion technique with PET and CT images acquired separately using a vacuum cushion as a fixation device. SUBJECTS AND METHODS: Forty-four patients underwent whole-body PET using 18F-fluoro-2-deoxy-D-glucose (FDG) followed by CT with IV contrast material. The patients were carefully fixed in an individually molded cushion to provide the same positioning for both examinations. The PET and CT images were fused on a workstation by using the lower margin of the urinary bladder as a reference. The degree of misregistration was evaluated for the physiologic uptake of the liver and kidneys and for the pathologic uptake of lesions. RESULTS: The average deviation of the center point of the liver between the two images was 6.6 +/- 8.7 (SD) mm in the craniocaudal direction, 1.9 +/- 5.1 mm in the anteroposterior direction, and 2.3 +/- 7.0 mm in the right-left direction. This value in the craniocaudal direction was 4.7 +/- 8.7 mm in the right kidney and 4.0 +/- 8.8 mm in the left kidney. Above the diaphragm, the deviations of the center point of movable and static lesions were 11.7 +/- 3.4 mm and 10.4 +/- 5.3 mm, respectively. Below the diaphragm, those of movable and static lesions were 9.7 +/- 2.5 mm and 6.9 +/- 2.9 mm, respectively. CONCLUSION: Our preliminary data indicate that this technique is a simple and practical method for manual image fusion that may be acceptable in clinical settings.

Feasibility Studies↗

Detectability of hypometabolic regions in mild Alzheimer disease: function of time after the injection of 2-[fluorine 18]-fluoro-2-deoxy-D-glucose.

BACKGROUND AND PURPOSE: 2-[Fluorine 18]-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) has played an important role in detecting hypometabolic regions in the brains of patients with dementia. To our knowledge, the optimal imaging time for dementia has not been investigated. The aim of this study was to evaluate the sensitivity of the early scanning (ES) compared with late scanning (LS) for demonstrating decreased regional glucose metabolism in patients with Alzheimer disease (AD). METHODS: Twenty patients with mild AD (mean age +/- standard deviation, 64.8 +/- 5.2 years) and 20 age- and sex-matched healthy volunteers (age, 65.9 +/- 4.5 years) were underwent FDG PET. Their cerebral glucose metabolic images were obtained on ES at 30-42 minutes and LS at 60-72 minutes after the administration of FDG 185-346 MBq. We compared regional cerebral metabolic images in a voxel-by-voxel analysis with statistical parametric mapping between patients with AD and control subjects and evaluated the difference in the hypometabolic regions between the two scans. RESULTS: In the AD-to-healthy comparison, LS at the P < .001 level of significance showed more extensive and significant hypometabolic areas than did ES. CONCLUSION: These results indicate that LS is superior to ES in detecting hypometabolic regions in patients with AD. For patients with AD, emission scanning soon after the administration of FDG is probably not advised.

Aged↗

Validation of anatomical standardization of FDG PET images of normal brain: comparison of SPM and NEUROSTAT.

PURPOSE: Statistical parametric mapping (SPM) and NEUROSTAT (NS) are widely used for intersubject statistical analysis of brain images. We investigated individual anatomical variations after standardization of 18F-fluorodeoxyglucose positron emission tomography (FDG PET) images of normal brain and compared the differences in the standardized images obtained from SPM and NS. METHODS: Twenty healthy normal subjects were recruited for FDG PET and magnetic resonance imaging (MRI) studies. Sylvian fissures (SF), cingulate sulci (CingS) and central sulci (CtlS) were marked on the brain surface of each individual's co-registered MR images. Then spatial standardization was performed on each subject's PET images using SPM99 and NS with NS's FDG template image, and each subject's MR images (with the SF, CingS, and CtlS marked in advance) were standardized using the sets of parameters obtained from PET standardization by SPM and NS, respectively. The coordinates of each subject's SF, CingS, and CtlS detected on the MR images standardized by the two methods were measured and compared with those on the template images. RESULTS: The mean individual deviations from the averaged coordinates for the markers on the SF, CingS and CtlS standardized by SPM and by NS were no more than 0.21-1.15 mm. The number of voxels within the brain volume on standardized MR images of all 20 subjects was 88.0% of the total number of brain volume voxels for SPM and 85.3% for NS. CONCLUSION: This study demonstrates that SPM and NS yield relatively small differences in standardization and that both methods are effective and valid for PET studies in normal subjects.

Adolescent↗

Usefulness of FDG-PET in detecting an ADH-secreting tumor: a case report.

We report a case of a 41-year-old woman who was diagnosed as having the syndrome of inappropriate secretion of ADH (SIADH). There was no evidence of any disorders of the central nervous system, lung diseases, or drugs causing SIADH. Positron emission tomography (PET) using (18)F-fluorodeoxyglucose (FDG) was performed and indicated a tumor of the uterine cervix. After resection of the tumor, both serum sodium level and serum osmolarity were normalized concomitantly with a decrease in serum ADH level. This is the first case report suggesting the usefulness of a FDG-PET scan to detect an occult cancer responsible for SIADH. It seems plausible that FDG-PET may be helpful in the diagnosis of other ectopic hormone-producing tumors such as ectopic ACTH-producing tumors that cause Cushing's syndrome.

Journal Article↗

[Evaluation of optimized injection dose and acquisition time using body mass index for three-dimensional whole-body FDG-PET].

OBJECTIVE: The standardized uptake value (SUV) is a relative measure of tracer uptake in tissue used in (18)F-FDG PET. However, the quality of ordered subset expectation maximization (OS-EM) images is sensitive to the number of iterations, because a large number of iterations leads to images with checkerboard noise. The main advantage of data acquisition in the three-dimensional (3D) mode is the high sensitivity to better exploit the intrinsic spatial resolution and the lower injection dose given to patients. In the 3D mode, the scatter fraction is higher, and, for a given administered dose, the random fraction is higher than that in the two-dimensional mode, which implies that correction methods need to be more accurate. Moreover, in clinical oncology (18)F-FDG PET studies, patients have a wide variety of body shapes and sizes, which may impact image statistics. Consequently, it is necessary to make constant the acquisition (true) counts. The purpose of this study was to optimize injection dose and acquisition time in consideration of body mass index (BMI) for 3D whole-body (18)F-FDG PET. METHODS: A dedicated PET scanner, SIEMENS ECAT EXACT HR(+), was used to scan images of clinical data. The injection dose for BMI of <14-19, 19-22, 22-25, and 25< (kg/m(2)) were, 92.5 MBq, 111.0 MBq, 129.5 MBq, and 148.0 MBq, respectively. The emission scan time per bed position for BMI of <14-19, 19-22, 22-25, and >25 (kg/m(2)) were, 120, 120, 180, and 240 sec, respectively. A total of 20 patient subjects were evaluated as to true counts per bin (T/bin) of sinogram data and measured activity concentrations for the region of interest in the liver section. RESULTS: T/bin was stable using an optimized protocol that took into consideration the BMI for any type of body morphology. The overall coefficient of variation was 7.27% for radioactivity concentration. Additionally, Gaussian filtering (8 mm FWHM) after reconstruction by the OS-EM method provided stable SUV values even when the iteration number was increased 30 times over. CONCLUSION: Optimization of injection dose and acquisition time indicated that BMI was a clinically useful acquisition protocol for 3D whole-body (18)F-FDG PET.

Body Mass Index↗

[Development of method to estimate delay time for arterial imput function with [15O]CO2-PET study using sinogram data and attenuation map].

The difference in tracer arrival times between the external radiation detector and the brain following administration of radioactivity (delay time) must be estimated correctly in order to quantitatively measure regional cerebral blood flow (rCBF) with positron emission tomography and [15O]H2O by autoradiographic method. Instead of intervenous injection of [15O]H2O, bolus inhalation of [15O]CO2 gas is sometimes used to simplify the measurement of rCBF. In the case of [15O]CO2, radioactive gas in mask and nasal cavity contributes large artifact on the sinogram data and it is difficult to estimate delay time from the sinogram data. In this paper, we proposed a new method to estimate the delay time using the sinogram data and the attenuation map (attenuation weighted sinogram method). In the present method, the attenuation map was used to eliminate the effect of the gas outside the brain region from the sinogram data. For the validation of the present method, PET data with [15O]CO2 (n = 10) were analyzed. Three methods, namely the image method, the sinogram method and the attenuation weighted sinogram method were used to estimate the delay time. The estimated delay times and calculated rCBF images by three methods were compared. Due to the radioactivity outside of the brain, the sinogram method significantly overestimated the delay time and thus underestimated the rCBF value compared with the image base method. On the other hand, there were good agreements between the delay times estimated by the attenuation weighted sinogram method and the image method. The present method can eliminate the effect of the radioactivity outside of the brain on the sinogram data and estimate the delay time accurately and fast enough for clinical use.

Autoradiography↗

[Diagnostic imaging--recent progress].

Current advances in the diagnostic imaging for lung cancer includes multidetector-row CT (MDCT), lung cancer screening using low-dose MDCT and fluorodeoxyglucose positron emission tomography (FDG-PET) imaging. There is no question about the clinical usefulness of MDCT, and the further development of the hardware and the software of MDCT will open new horizons for CT diagnosis. PET is not an alternative modality to CT but a supplementary one, which adds metabolic information to the morphology. Recently, experimental research on the refraction imaging of human lung specimens has been performed with synchrotron radiation. With progressive refinement, this technique may come to have some practical purpose in diagnosing lung cancer in vivo.

Carcinoma, Squamous Cell↗

Differences in cerebral metabolic impairment between early and late onset types of Alzheimer's disease.

UNLABELLED: The purpose of this study was to delineate the specific patterns of cerebral glucose metabolism with regard to the time of onset of Alzheimer's disease (AD). METHODS: Two groups of 20 AD patients with different ages of onset were examined. The early onset (EO) and late onset (LO) groups had mean ages of onset of 53.9 and 72.7 years. Groups of age-matched normal subjects were used as controls. A regional relative cerebral glucose metabolic image of each subject was obtained by 2-[18F] fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET). NEUROSTAT program was used for spatial normalization and voxel-based statistical parametric mapping (SPM) 99 was used for statistical analyses. RESULTS: Both AD groups had significant hypometabolic regions in the bilateral parieto-temporal regions compared with the age-matched groups. The EO group had more severe hypometabolism in the bilateral parietal and posterior cingulate cortices and precuneus region than the LO group. However, LO group showed no significant hypometabolic regions compared to the EO group. CONCLUSION: The effects of time of AD onset were delineated as a double dissociation, that is, EO AD patients have a more severe reduction of glucose metabolism. Our finding suggests the existence of biological subtypes of AD.

Adult↗

Voxel-based comparison of regional cerebral glucose metabolism between PSP and corticobasal degeneration.

OBJECTIVES: Progressive supranuclear palsy (PSP) and corticobasal degeneration (CBD) are neurodegenerative disorders that may be accompanied by dementia and parkinsonism as clinical symptoms. The purpose of this study was to elucidate cerebral metabolic differences of these two diseases with cognitive impairments by [18F] fluorodeoxyglucose (FDG) and positron emission tomography (PET). METHODS: A total of 12 patients with PSP (age: 62.8+/-6.0 years old, m: 7, f: 5, Mini-Mental State Examination (MMSE): 23.4+/-2.6), 12 patients with CBD (age: 64.8+/-6.3 years old, m: 6, f: 6, MMSE: 22.9+/-4.5), and age-matched healthy subjects (normal control (NC)) (age: 63.8+/-7.7 years old, m: 7, f: 5) were subjected to FDG-PET to obtain glucose metabolic images. We compared regional cerebral metabolic images by a voxel-by-voxel analysis with statistical parametric mapping (SPM) among PSP, CBD, and NC subjects, and evaluated differences of hypometabolic regions. RESULTS: The patients with PSP showed reduced cerebral glucose metabolism in the medial and lateral frontal gyri, basal ganglia, and midbrain compared with NC, whereas the patients with CBD showed significant reduction in the parietal lobes (p<0.001). SPM also revealed parietal hypometabolism in CBD patients compared with PSP patients (p<0.001). CONCLUSIONS: The predominant parietal glucose metabolic reduction in CBD patients was different from previously reported findings. This finding would be the characteristic substance of patients with CBD accompanying cognitive impairments. Our findings suggest that measurement of glucose metabolism by PET and a voxel-based analysis is useful to understand the pathophysiology of these two diseases with cognitive impairments.

Brain↗

Gender differences in cerebral glucose metabolism: a PET study.

OBJECTIVE: Some studies have examined gender differences in brain function based on cerebral blood flow and cerebral metabolism by using positron emission tomography (PET). However, the findings of these studies are controversial and most of them were analyzed by the regions of interest (ROIs) method. Here, we evaluated gender differences of cerebral glucose metabolism under the resting state in a voxel-based analysis. METHODS: We studied 44 healthy volunteers (22 females, 63.0+/-6.3 years, and 22 males, 63.1+/-8.4 years). Cerebral glucose metabolic images were obtained with (18)F-fluorodeoxyglucose (FDG) and PET. All individual data were transformed to standard brain space and the male and female groups were compared using statistical parametric mapping (SPM). RESULTS: The males had significantly higher glucose metabolism in the right insula, middle temporal gyrus, and medial frontal lobe than the females. Glucose metabolism in the hypothalamus was significantly higher in females than in males. There was a significant correlation between aging and glucose metabolism in the left thalamus in males and in the left caudate nucleus and hypothalamus in females. In males, but not females, there was a significant asymmetry between the bilateral hemispheres. CONCLUSION: We found that there were obvious gender differences in regional cerebral glucose metabolism and this is the first report of higher glucose metabolism in the hypothalamus in females than in males.

Aged↗

Variation in FDG uptakes in different regions in normal human brain as a function of the time (30 and 60 minutes) after injection of FDG.

OBJECTIVE: The authors' goal was to determine whether FDG uptakes in various regions of the brain are different for early and late scanning time in positron emission tomography (PET). METHOD: F-18 fluorodeoxyglucose (FDG) PET was performed on 15 healthy normal subjects to obtain early and late acquisition glucose metabolic images (30 and 60 min after FDG injection), respectively. The two sets of images were compared in a voxel-by-voxel analysis. RESULTS: In the bilateral posterior cingulate gyrus, parietal and frontal association cortices, and subcallosal cortices, the FDG uptakes were larger on the late scan image than on the early scan image, and the FDG uptakes were larger in the cerebellar hemisphere, vermis and frontal basis on the early scan image than on the late scan image. CONCLUSIONS: These results suggest that there are different regional FDG uptakes depending on the scanning time after FDG injection and we must be careful in replacing conventional FDG PET scanning with early scanning in FDG PET study.

Aged↗

[Performance evaluation of continuous blood sampling system for PET study: comparison of three detector-systems].

OBJECTIVES: To measure cerebral blood flow with 15O'PET, it is necessary to measure the time course of arterial blood radioactivity. We examined the performance of three different types of continuous blood sampling system. METHODS: Three kinds of continuous blood sampling system were used: a plastic scintillator-based beta detector (conventional beta detector (BETA)), a bismuth germanate (BGO)-based coincidence gamma detector (Pico-count flow-through detector (COINC)) and a Phoswich detector (PD) composed by a combination of plastic scintillator and BGO scintillator. Performance of these systems was evaluated for absolute sensitivity, count rate characteristic, sensitivity to background gamma photons, and reproducibility for nylon tube geometry. RESULTS: The absolute sensitivity of the PD was 0.21 cps/Bq for 68Ga positrons at the center of the detector. This was approximately three times higher than BETA, two times higher than COINC. The value measured with BETA was stable, even when background radioactivity was increased. The count rate characteristic of the PD and COINC was linear up to 8 kcps. The reproducibility of sensitivity for nylon tube geometry of COINC was the smallest (C.V. = 1.00%) among the three. PD was the weights the least (3.5 kg) among the three, which is convenient for clinical use. CONCLUSIONS: Each detector has unique characteristics derived from its own structure. Although the performance of all three detectors meets clinical requirement, PD had the highest physical performance.

Cerebrovascular Circulation↗