PubMed Health⌕ Search

Biomedical subjects

Shalini Gautam

Publications and source records attributed to Shalini Gautam.

2 recordsLinked to original sources

Synthetic blood group antigens for anti-A removal device and their interaction with monoclonal anti-A IgM.

Removal of blood group antibodies against the donor organ prior to ABO-incompatible transplantation can prevent episodes of hyperacute rejection. We are developing a specific antibody filter (SAF) device consisting of immobilized synthetic Atrisaccharide antigens conjugated to polyacrylamide (Atri-PAA) to selectively remove anti-A antibodies directly from whole blood. In this study, we evaluated eight anti-A IgM monoclonal antibodies (mAbs) using Enzyme-Linked Immunosorbent Assay (ELISA) to determine their specificity for binding to Atri-PAA. Five of the eight mAbs met our criteria for specificity by binding to Atri-PAA with at least five times greater affinity compared to the negative controls. These selected mAbs will be studied for their binding characteristics to Atri-PAA which will aid in the development of the SAF. The study of kinetics of antibody removal and quantification of antibody removal will be used in our mathematical model to maximize the antibody removal rate and binding capacity of the SAF.

Animals↗

Modeling continuous aqueous two-phase systems for control purposes.

A mathematical model was proposed to allow the analysis of steady-state and transient behaviors of single-stage continuous aqueous two-phase systems. Since the complete system of simultaneous equations contains more equations than unknown variables, a program based on the method of least squares was developed to solve the problem. The methodology was tested using a system composed of thaumatin, sodium chloride, and a contaminant protein. A poly(ethylene-glycol)/phosphate salt/water system was selected to isolate the thaumatin. For the steady-state and transient operations, a constrained optimization procedure--from the Matlab Optimization Toolbox (MathWork, Inc.)--was implemented after recasting the system of equations as a minimization problem. Euler's method was used in the transient case to discretize the differential equations. The steady-state concentrations agreed with published data. An input-output model based on a 4% step change decrease in the inlet stream flow rate showed that output variables such as concentrations of sodium chloride and phosphate salt settled to their final values in different time periods. The proposed analysis may be helpful in the dynamic control of large-scale commercial extractor units using advanced control schemes.

Models, Theoretical↗