PubMed Health⌕ Search

Biomedical subjects

Shalini Narayana

Publications and source records attributed to Shalini Narayana.

8 recordsLinked to original sources

Intensity modulation of TMS-induced cortical excitation: primary motor cortex.

The intensity dependence of the local and remote effects of transcranial magnetic stimulation (TMS) on human motor cortex was characterized using positron-emission tomography (PET) measurements of regional blood flow (BF) and concurrent electromyographic (EMG) measurements of the motor-evoked potential (MEP). Twelve normal volunteers were studied by applying 3 Hz TMS to the hand region of primary motor cortex (M1(hand)). Three stimulation intensities were used: 75%, 100%, and 125% of the motor threshold (MT). MEP amplitude increased nonlinearly with increasing stimulus intensity. The rate of rise in MEP amplitude was greater above MT than below. The hemodynamic response in M1(hand) was an increase in BF. Hemodynamic variables quantified for M1(hand) included value-normalized counts (VNC), intensity (z-score), and extent (mm(3)). All three hemodynamic response variables increased nonlinearly with stimulus intensity, closely mirroring the MEP intensity-response function. VNC was the hemodynamic response variable which showed the most significant effect of TMS intensity. VNC correlated strongly with MEP amplitude, both within and between subjects. Remote regions showed varying patterns of intensity response, which we interpret as reflecting varying levels of neuronal excitability and/or functional coupling in the conditions studied.

Adult↗

Column-based model of electric field excitation of cerebral cortex.

A model to explain the orientation selectivity of the neurophysiologic effects of electric-field transients applied to cerebral cortex is proposed and supported with neuroimaging evidence. Although it is well known that transcranial magnetic stimulation (TMS) excites cerebral cortex in an orientation-selective manner, a neurophysiologically compelling explanation of this phenomenon has been lacking. It is generally presumed that TMS-induced excitation is mediated by horizontal fibers in the cortical surfaces nearest to the stimulating coil, i.e., at the gyral crowns. No evidence exists, however, that horizontal fibers are orientation selective either anatomically or physiologically. We used positron emission tomography to demonstrate that TMS-induced cortical activation is selectively sulcal. This observation allows the well-established columnar organization of cerebral cortex to be invoked to explain the observed orientation selectivity. In addition, Rushton's cosine principle can used to model stimulation efficacy for an electrical field applied at any cortical site at any intensity and in any orientation.

Adult↗

Evaluation of an image-guided, robotically positioned transcranial magnetic stimulation system.

The emergence of transcranial magnetic stimulation (TMS) as a tool for investigating the brain has been remarkable over the past decade. While many centers are now using TMS, little has been done to automate the delivery of planned TMS stimulation for research and/or clinical use. We report on an image-guided robotically positioned TMS system (irTMS) developed for this purpose. Stimulation sites are selected from functional images overlaid onto anatomical MR images, and the system calculates a treatment plan and robotically positions the TMS coil following that plan. A new theory, stating that cortical response to TMS is highest when the induced E-field is oriented parallel to cortical columns, is used by the irTMS system for planning the position and orientation of the TMS coil. This automated approach to TMS planning and delivery provides a consistent and optimized method for TMS stimulation of cortical regions of the brain. We evaluated the positional accuracy and utility of the irTMS system with a B-shaped TMS coil. Treatment plans were evaluated for sites widely distributed about a head phantom with well-defined landmarks. The overall accuracy in positioning the planned site of the TMS coil was approximately 2 mm, similar to that reported for the robot alone. The estimated maximum range of error in planned vs. delivered E-field strength was +4%, suggesting a high degree of accuracy and reproducibility in the planned use of the irTMS system.

Brain↗

CBF changes during brain activation: fMRI vs. PET.

The changes in regional cerebral blood flow (rCBF) associated with the changes in neuronal activity are routinely measured both by positron emission tomography (PET) and functional magnetic resonance imaging (fMRI) techniques. However, direct comparison has not been performed to determine similarities and differences of PET and fMRI techniques in determining the rCBF response to brain activation. In the present study, a quantitative comparison of the functional rCBF maps obtained by PET and fMRI are made by performing an activation study in a single group of subjects under precisely controlled conditions and using identical visual stimuli. Twelve healthy volunteers participated in the activation study using the visual checkerboard stimulation with flip frequency at 8 Hz. By selecting the conjunctive pixels which activated on both PET and fMRI maps, the change in rCBF measured by fMRI was 36.95 +/- 2.54%, whereas the value measured by PET was 38.79 +/- 2.63%. Our results have demonstrated that there is no statistically significant difference (P = 0.22) in the measurements of rCBF change between MRI and PET methods.

Algorithms↗

Estimation of the local statistical noise in positron emission tomography revisited: practical implementation.

The purpose of this report is to implement novel modifications to overcome the limitations of an existing algorithm for estimating the local statistical noise in a positron emission tomography (PET) image without performing repeated measures. The original algorithm is based on a modification of the filtered back-projection algorithm that allows the variance to be estimated using only a single sinogram. In addition, the effects of photon absorption, random coincidences, radioactive decay, and detector nonuniformity are taken into account. However, there are some limitations when applying this method with modern scanners. In particular, it is common practice to interleave the projections in the sinogram (to increase the sampling rate along each projection) and to perform an interpolation when actually back-projecting to reconstruct the images. Both of these procedures introduce covariance among the elements of the projections, which is cumbersome and impractical to deal with using the existing technique for creating a variance image. An alternative image reconstruction scheme that is shown to be equivalent to image reconstruction using traditional filtered back-projection greatly simplifies the estimation of the variance image. The proposed methods were tested by Monte Carlo simulations and by using repeated scans of a uniform phantom filled with F-18. Results demonstrate that the proposed methods are very rigorous and stable when compared to calculations of the local variance using either repeated measures with a large number of measurements, or region-of-interest estimates of the variance, assuming homogeneous variance structure. In addition, strategies for extending the proposed technique are discussed that would permit the estimation of the variance due to measurement error of a pixel in a brain map from both single subjects and pooled group data.

Algorithms↗

Positron emission tomography during transcranial magnetic stimulation does not require mu-metal shielding.

Recording brain activity using positron emission tomography (PET) during the stimulation of different parts of the brain by transcranial magnetic stimulation (TMS) permits the mapping of neural connections in the living human brain. However, controversy remains regarding the need for micro-metal shielding of the PET scanner during magnetic stimulation. The aim of this study was to test the effects of magnetic fields generated by TMS on PET data acquisition. With TMS-on and -off in the PET field of view, transmission scans with a (68)Ge/(68)Ga pin source and emission scans with an uniform phantom filled with water and (18)F were acquired. The frequency and intensity of stimulation were set at 3-5 Hz and 70-80% of the maximum output of the stimulator, respectively. The TMS coil was placed at several locations inside the PET gantry, and the main field direction of the TMS coil was varied between parallel and perpendicular orientation to the scanner's axis. Qualitative and quantitative evaluation of the sinograms of transmission PET scans and reconstructed emission images indicated no measurable differences between TMS-on and -off and post-TMS conditions for any position or orientation. The long distance between the TMS coil and the detector block in the PET scanner, as well as the rapid reduction of the magnetic field with distance (3% of maximum field at 10 cm, in air), could explain the lack of TMS interference. The brief duration (approximately 250 micros) of the TMS pulses relative to the total PET acquisition time would also explain the lack of TMS effects. The lack of TMS effects on the PET scanner, as well as PET imaging without any shielding, has been reported by other laboratories.

Brain↗