PubMed Health⌕ Search

Biomedical subjects

Shane A Catledge

Publications and source records attributed to Shane A Catledge.

7 recordsLinked to original sources

Mesenchymal stem cell adhesion and spreading on microwave plasma-nitrided titanium alloy.

Improved methods to increase surface hardness of metallic biomedical implants are being developed in an effort to minimize the formation of wear debris particles that cause local pain and inflammation. However, for many implant surface treatments, there is a risk of film delamination due to the mismatch of mechanical properties between the hard surface and the softer underlying metal. In this article, we describe the surface modification of titanium alloy (Ti-6Al-4V), using microwave plasma chemical vapor deposition to induce titanium nitride formation by nitrogen diffusion. The result is a gradual transition from a titanium nitride surface to the bulk titanium alloy, without a sharp interface that could otherwise lead to delamination. We demonstrate that vitronectin adsorption, as well as the adhesion and spreading of human mesenchymal stem cells to plasma-nitrided titanium is equivalent to that of Ti-6Al-4V, while hardness is improved 3- to 4-fold. These in vitro results suggest that the plasma nitriding technique has the potential to reduce wear, and the resulting debris particle release, of biomedical implants without compromising osseointegration; thus, minimizing the possibility of implant loosening over time.

Cell Adhesion↗

Ultra-smooth nanostructured diamond films deposited from He/H2/CH4/N2 microwave plasmas.

Addition of He to a high CH4 content (10.7 vol%) H2/CH4/N2 feedgas mixture for microwave plasma chemical vapor deposition produced hard (58-72 GPa), ultra-smooth nanostructured diamond films on Ti-6AI-4V alloy substrates. Upon increase in He content up to 71 vol%, root mean squared (RMS) surface roughness of the film decreased to 9-10 nm and average diamond grain size to 5-6 nm. Our studies show that increased nanocrystallinity with He addition in plasma is related to plasma dilution, enhanced fragmentation of carbon containing species, and enhanced formation of CN radical.

Diamond↗

Nanoindentation on porous bioceramic scaffolds for bone tissue engineering.

We report nanoindentation mechanical properties measurements on porous ceramic scaffolds made for tissue engineering applications. The scaffolds have been made from tricalcium phosphate (TCP), hydroxyapatite (HA) nanopowder and mixed powders of HA (50 wt%) and TCP (50 wt%) using the polyurethane sponge method, which produces open porous ceramic scaffolds through replication of a porous polymer template. The scaffolds prepared by this method have a controllable pore size and interconnected pore structure. The crystal structures and morphology of porous scaffolds were determined by X-ray diffraction (XRD) and atomic force microscopy (AFM) respectively. Nanoindentation measurements to a depth of 600 nm showed a Young's modulus value of 10.3 GPa for HA+TCP composite scaffolds and 1.5 GPa for TCP scaffolds. The hardness values were 240 MPa for HA+TCP composites and 21 MPa for TCP sample respectively. The results showed that the mechanical properties of the biodegradable scaffolds can be considerably enhanced with the addition of HA while maintaining the interconnected open pores and pore geometry desirable for bone tissue engineering.

Biocompatible Materials↗

Mechanical wear behavior of nanocrystalline and multilayer diamond coatings on temporomandibular joint implants.

We used microwave plasma chemical vapor deposition to deposit nanocrystalline and multilayer (nanocrystalline/microcrystalline/nanocrystalline) diamond thin films on Ti-6AI-4V substrates imitating the condyle and fossa components of the temporomandibular joint. We tested the condyle/fossa pairs for wear in a mandibular movement simulator for an equivalent of two years of clinical use. Analysis of the wear surfaces by optical microscopy, scanning electron microscopy (SEM), and Raman spectroscopy showed that damage in both the films was minimal, no loss of film occurred and the wear performance was superior for the multilayer film. Comparisons with an uncoated condyle/fossa pair showed that the coated temporomandibular joint pairs had improved wear performance.

Diamond↗

Mesenchymal stem cell adhesion and spreading on nanostructured biomaterials.

Bone marrow-derived human mesenchymal stem cells were seeded in serum-free media onto ion beam-deposited nanostructured metalloceramic (Ti-Cr-N) films and plasma-nitrided titanium disks, which were left uncoated as well as precoated with fetal bovine serum. Precoating the disks with serum appears to stimulate cell spreading on both the titanium nitride and metalloceramic materials for as little as 1 hour incubation time. The implication is that both of these materials can adsorb serum proteins in amounts sufficient to influence cell adhesion and spreading for potentially improved in vivo response of orthopedic and dental implants. The materials in this study may prove to exhibit enhanced biological and mechanical properties when compared to conventional micron-scale implant materials such as titanium or cobalt-chrome alloys.

Bone Substitutes↗

Surface crystalline phases and nanoindentation hardness of explanted zirconia femoral heads.

One new and nine explanted zirconia femoral heads were studied using glancing angle X-ray diffraction, scanning electron microscopy, and nanoindentation hardness techniques. All starting zirconia implants consisted only of tetragonal zirconia polycrystals (TZP). For comparison, one explanted alumina femoral head was also studied. Evidence for a surface tetragonal-to-monoclinic zirconia phase transformation was observed in some implants, the extent of which was varied for different in-service conditions. A strong correlation was found between increasing transformation to the monoclinic phase and decreasing surface hardness. Microscopic investigations of some of the explanted femoral heads revealed ultra high molecular weight polyethylene and metallic transfer wear debris.

Journal Article↗

Nanostructured ceramics for biomedical implants.

Recent progress in the synthesis, characterization, and biological compatibility of nanostructured ceramics for biomedical implants is reviewed. A major goal is to develop ceramic coating technology that can reduce the friction and wear in mating total joint replacement components, thus contributing to their significantly improved function and longer life span. Particular attention is focused on the enhancement of mechanical properties such as hardness, toughness, and friction coefficient and on the bioactivity as they pertain to the nanostructure of the material. The development of three nanostructured implant coatings is discussed: diamond, hydroxyapatite, and functionally graded metalloceramics based on the Cr-Ti-N ternary system. Nanostructured diamond produced by chemical vapor deposition (CVD) techniques and composed of nano-size diamond grains have particular promise because of the combination of ultrahigh hardness, improved toughness over conventional microcrystalline diamond, low friction, and good adhesion to titanium alloys. Nanostructured processing applied to hydroxyapatite coatings is used to achieve the desired mechanical characteristics and enhanced surface reactivity and has been found to increase osteoblast adhesion, proliferation, and mineralization. Finally, nanostructured metalloceramic coatings provide continuous variation from a nanocrystalline metallic bond at the interface to the hard ceramic bond on the surface and have the ability to overcome adhesion problems associated with ceramic hard coatings on metallic substrates.

Animals↗