PubMed Health⌕ Search

Biomedical subjects

Shaolian Zhou

Publications and source records attributed to Shaolian Zhou.

9 recordsLinked to original sources

Simultaneous determination of norethindrone and ethinyl estradiol in human plasma by high performance liquid chromatography with tandem mass spectrometry--experiences on developing a highly selective method using derivatization reagent for enhancing sensitivity.

In the present work, for the first time, a liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the simultaneous analysis of norethindrone, and ethinyl estradiol, was developed and validated over the concentration range of 50-10000pg/ml and 2.5-500pg/ml, respectively, using 0.5 ml of plasma sample. Norethindrone, ethinyl estradiol, and their internal standards norethindrone-(13)C2, and ethinyl estradiol-d4, were extracted from human plasma matrix with n-butyl chloride. After evaporation of the organic solvent, the extract was derivatized with dansyl chloride and the mixture was injected onto the LC-MS/MS system. The gradient chromatographic elution was achieved on a Genesis RP-18 (50 mm x 4.6 mm, 3 microm) column with mobile phase consisted of acetonitrile, water and formic acid. The flow rate was 1.0 ml/min and the total run time was 5.0 min. Important parameters such as sensitivity, linearity, matrix effect, reproducibility, stability, carry-over and recovery were investigated during the validation. The inter-day precision and accuracy of the quality control samples at low, medium and high concentration levels were <6.8% relative standard deviation (RSD) and 4.4% relative error (RE) for norethindrone, and 4.2% RSD and 5.9% RE for ethinyl estradiol, respectively. Chromatographic conditions were optimized to separate analytes of interest from the potential interference peaks, arising from the derivatization. This method could be used for pharmacokinetic and drug-drug interaction studies in human subjects.

Chromatography, High Pressure Liquid↗

High-throughput biological sample analysis using on-line turbulent flow extraction combined with monolithic column liquid chromatography/tandem mass spectrometry.

A high-throughput liquid chromatography/tandem mass spectrometry (LC/MS/MS) method, which combines on-line sample extraction through turbulent flow chromatography with a monolithic column separation, has been developed for direct injection analysis of drugs and metabolites in human plasma samples. By coupling a monolithic column into the system as the analytical column, the method enables running 'dual-column' extraction and chromatography at higher flow rates, thus significantly reducing the time required for the transfer and mixing of extracted fraction onto the separation column as well as the time for gradient separation. A strategy of assessing and reducing the matrix suppression effect on the on-line extraction LC/MS/MS has also been discussed. Experiments for evaluating the resolution, peak shape, sensitivity, speed, and matrix effect were conducted with dextromethorphan and its metabolite dextrorphan as model compounds in human plasma matrix. It was demonstrated that the total run time for this assay with a baseline separation of two analytes is less than 1.5 min.

Analgesics, Opioid↗

The use of chemical derivatization to enhance liquid chromatography/tandem mass spectrometric determination of 1-hydroxypyrene, a biomarker for polycyclic aromatic hydrocarbons in human urine.

This article presents an analytical approach that used chemical derivatization to enhance mass spectrometric (MS) response in electrospray ionization (ESI) mode of 1-hydroxypyrene (1-OHP), a commonly used biomarker to monitor human exposure to polycyclic aromatic hydrocarbons (PAHs). The enhancement successfully enabled the desired detection of 50 pg/mL in human urine. The introduction of an MS-friendly dansyl group to 1-OHP enhanced both ionization efficiency in the ESI source and collision-activated dissociation (CAD) in the collision cell. The response increase was estimated to be at least 200-fold, and enabled the reduction of sample size to only 100 microL. The selective MS detection also facilitated a fast (run time 3 min) liquid chromatography (LC) method which successfully resolved the analyte and interferences. The sample processing procedure included enzymatic hydrolysis of glucuronide and sulfate conjugates, liquid-liquid extraction, derivatization with dansyl chloride and a final liquid-liquid extraction to generate clean extracts for LC/MS/MS analysis. This approach has been validated as sensitive, linear (50-1000 pg/mL), accurate and precise for the quantitation of 1-OHP in human urine. This is the first report of using chemical derivatization to enhance MS/MS detection with fast chromatography in the determination of 1-OHP in human urine.

Biomarkers↗

Development, validation and transfer of a hydrophilic interaction liquid chromatography/tandem mass spectrometric method for the analysis of the tobacco-specific nitrosamine metabolite NNAL in human plasma at low picogram per milliliter concentrations.

A highly sensitive bioanalytical method based on a simple liquid/liquid extraction and hydrophilic interaction liquid chromatography with tandem mass spectrometry (HILIC/MS/MS) analysis has been developed, validated and transferred for the determination of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), a tobacco-specific nitrosamine metabolite. Deuterated NNAL (NNAL-d(4)) was synthesized and used as the internal standard. This method can be used for the analysis of free and total NNAL (free NNAL plus NNAL-gluc) in K(3)-EDTA human plasma. Free NNAL and NNAL-d(4) are extracted from human plasma by liquid/liquid extraction. To analyze for total NNAL and the internal standard, a separate aliquot of the K(3)-EDTA human plasma is treated with beta-glucuronidase to deconjugate the NNAL-gluc; the total NNAL and internal standard are then extracted using liquid/liquid extraction. After drying down under nitrogen, the residue is reconstituted with acetonitrile and analyzed using positive ion electrospray and HILIC/MS/MS at a flow rate of 1.0 mL/min. The chromatographic run time is 1.0 min per injection, with retention time for both NNAL and NNAL-d(4) of 0.75 min with a capacity factor (k') of 2. The standard curve range for this assay is from 5.00-1000 pg/mL for both free and total NNAL, using a total plasma sample volume of 1.0 mL. The interday precision and accuracy of the quality control (QC) samples demonstrated <7.6% relative standard deviation (RSD) and <3.3% relative error (RE) for free NNAL. For total NNAL, the interday precision and accuracy of the QC samples demonstrated <11.7% RSD and <2.8% RE. Optimization of enzyme hydrolysis of NNAL-gluc is discussed in detail. The overall recoveries for free and total NNAL and IS were 68.2 and 71.5% (free) and 70.7 and 65.5% (total). No adverse matrix effects were noticed for this assay.

Chromatography, High Pressure Liquid↗

Structures of two new "minimalist" modified nucleosides from archaeal tRNA.

The wyeosine (or wye) family of tricyclic ribonucleosides from archaeal and eukaryal tRNA(Phe) constitutes one of the most complex and interesting series of posttranscriptional RNA modifications, and has been the object of numerous studies of their chemical and biological synthesis and distribution. We report the structures of two minimally elaborated wye derivatives from archaea, raising the known number of wye nucleosides to eight: 3,4-dihydro-6-methyl-3-beta-d-ribofuranosyl-9H-imidazo[1,2-a]purine-9-one (symbol imG-14), and 3,4-dihydro-6,7-dimethyl-3-beta-d-ribofuranosyl-9H-imidazo[1,2-a]purine-9-one (symbol imG2). Structures were determined primarily by mass spectrometry, and confirmed by comparison of physicochemical properties with those of chemically synthesized nucleosides. The nucleosides contain no amino acid side chains at C-7 (1H-imidazo[1,2-a]purine nomenclature) and are the only wye derivatives not methylated at N-4. These features suggest a minimal role for wye methyl groups and side chains in maintenance of anticodon stem-loop structures, and support the concept that archaeal tRNA nucleoside modification motifs are generally simpler than those of their counterparts in eukarya and bacteria.

Archaea↗

Tandem mass spectrometry for structure assignments of wye nucleosides from transfer RNA.

The tricyclic wye nucleoside family of eight known members constitutes one of the most complex and interesting series of posttranscriptionally modified nucleosides in transfer RNA. The principal reaction paths represented in collision-induced dissociation mass spectra of wye bases and their analogs have been studied in order to determine those structural features that can be readily established by mass spectrometry. The main routes of fragmentation are determined by the presence vs. absence of an amino acid side chain at C-7 (1H-imidazo[1,2-a]purine nomenclature). The common methionine-related side chain is cleaved at two points, providing a ready means of establishing the presence and net level of side chain modification. For those molecules without a side chain, the initial reaction steps are characteristically controlled by the presence vs. absence of methyl at N-4, allowing determination of the methylation status of that site. In the latter case initial opening of the central (pyrimidine) ring, in analogy to the dissociation behavior of guanine, causes loss of identity of C-6/C-7 so that placement of a single methyl at either site is not possible. Subsequent complex reaction paths follow, which include loss of CO and sequential loss of two molecules of HCN.

Humans↗

Profiling pH changes in the electrospray plume.

Laser-induced fluorescence spectrometry is used to profile pH changes as droplets evaporate in an electrospray plume by measuring emission spectra of 2(or 4)-[10-(dimethylamino)-3-oxo-3H-benzo[c]xanthene-7-yl]-benzenedicarboxylic acid (carboxy SNARF-1), a pH-sensitive fluorescent dye. The observed pH changes depend on initial droplet pH and polarity. In some instances, small or negligible changes of pH are observed, consistent with expected buffering. The pH of initially acidic droplets decreases along the spray axis in both positive and negative ion modes, to an extent larger than expected from solvent evaporation. This phenomenon may be a manifestation of droplet cooling, droplet subdivision, or heterogeneous charge distribution within the spray plume or within individual ES droplets.

Journal Article↗

Qualitative assessment of monomer ratios in putative ionic terpolymer samples by electrospray ionization mass spectrometry with collision-induced dissociation.

Collision-induced dissociation in the source of an electrospray (ES) mass spectrometer was employed to characterize putative samples of the ionic terpolymer poly(styrene sulfonate-co-acrylic acid-co-2-acrylamido-2-methyl-1-propanesulfonic acid). Qualitative and semi-quantitative information about the monomer content was quickly obtainable from ES spectra, and indicated that some samples contained little or none of one or two expected comonomers. For two representative samples, confirmatory nuclear magnetic resonance (NMR) data were acquired. The NMR experiments required sample clean-up (to remove additives) and long acquisition times (up to 720 min) for 13C NMR. Cleanup also improved the ES results, providing better agreement with the NMR data. However, qualitative and semi-quantitative information was obtainable by ES (but not by NMR) without the cleanup step. Full quantitation of monomer ratios would require suitable standards, but even without such standards the ES measurements provide a rapid (<1 min) means for differentiating these samples (e.g., for process or quality control).

Journal Article↗