PubMed Health⌕ Search

Biomedical subjects

Shaowei Zhuang

Publications and source records attributed to Shaowei Zhuang.

6 recordsLinked to original sources

Chronic atrioventricular nodal vagal stimulation: first evidence for long-term ventricular rate control in canine atrial fibrillation model.

BACKGROUND: We have previously demonstrated that selective atrioventricular nodal (AVN) vagal stimulation (AVN-VS) can be used to control ventricular rate during atrial fibrillation (AF) in acute experiments. However, it is not known whether this approach could provide a long-term treatment in conscious animals. Thus, this study reports the first observations on the long-term efficacy and safety of this novel approach to control ventricular rate during AF in chronically instrumented dogs. METHODS AND RESULTS: In 18 dogs, custom-made bipolar patch electrodes were sutured to the epicardial AVN fat pad for delivery of selective AVN-VS by a subcutaneously implanted nerve stimulator (pulse width 100 micros or 1 ms, frequency 20 or 160 Hz, amplitude 6 to 10 V). Fast-rate right atrial pacing (600 bpm) was used to induce and maintain AF. ECG, blood pressure, and body temperature were monitored telemetrically. One week after the induction of AF, AVN-VS was delivered and maintained for at least 5 weeks. It was found that AVN-VS had a consistent effect on ventricular rate slowing (on average 45+/-13 bpm) over the entire period of observation. Echocardiography showed improvement of cardiac indices with ventricular rate slowing. AVN-VS was well tolerated by the animals, causing no signs of distress or discomfort. CONCLUSIONS: Beneficial long-term ventricular rate slowing during AF can be achieved by implantation of a nerve stimulator attached to the epicardial AVN fat pad. This novel concept is an attractive alternative to other methods of rate control and may be applicable in a selected group of patients.

Animals↗

Determinants of LV diastolic function during atrial fibrillation: beat-to-beat analysis in acute dog experiments.

Left ventricular (LV) diastolic function during atrial fibrillation (AF) remains poorly understood due to the complex interaction of factors and beat-to-beat variability. The purpose of the present study was to elucidate the physiological determinants of beat-to-beat changes in LV diastolic function during AF. The RR intervals preceding a given cardiac beat were measured from the right ventricular electrogram in 12 healthy open-chest mongrel dogs during AF. Doppler echocardiography and LV pressure and volume beat-to-beat analyses were performed. The LV filling time (FT) and early diastolic mitral inflow velocity-time integral (E(vti)) were measured using the pulsed Doppler method. The LV end-diastolic volume (EDV), peak systolic LV pressure (LVP), minimum value of the first derivative of LV pressure curve (dP/dt(min)), and the time constant of LV pressure decay (tau) were evaluated with the use of a conductance catheter for 100 consecutive cardiac cycles. Beat-to-beat analysis revealed a cascade of important causal relations. LV-FT showed a significant positive linear relationship with E(vti) (r = 0.87). Importantly, there was a significant positive linear relationship between the RR interval and LV-EDV in the same cardiac beat (r = 0.53). Consequently, there was a positive linear relationship between LV-EDV and subsequent peak systolic LVP (r = 0.82). Furthermore, there were significant positive linear and negative curvilinear relationships between peak systolic LVP and dP/dt(min) (r = 0.95) and tau (r = -0.85), respectively, in the same cardiac beat. In addition, there was a significant negative curvilinear relationship between dP/dt(min) and tau (r = -0.86). We have concluded that the determinants of LV diastolic function in individual beats during AF depend strongly on the peak systolic LVP. This suggests that the major benefit of slower ventricular rate appears related to lengthening of LV filling interval, promoting subsequent higher peak systolic LVP and greater LV relaxation.

Animals↗

Ventricular rate control by selective vagal stimulation is superior to rhythm regularization by atrioventricular nodal ablation and pacing during atrial fibrillation.

BACKGROUND: Selective atrioventricular nodal (AVN) vagal stimulation (AVN-VS) has emerged as a novel strategy for ventricular rate (VR) control in atrial fibrillation (AF). Although AVN-VS preserves the physiological ventricular activation sequence, the resulting rate is slow but irregular. In contrast, AVN ablation with pacemaker implantation produces retrograde activation (starting at the apex), with regular ventricular rhythm. We tested the hypothesis that, at comparable levels of VR slowing, AVN-VS provides hemodynamic benefits similar to those of ablation with pacemaker implantation. METHODS AND RESULTS: AVN-VS was delivered to the epicardial fat pad that projects parasympathetic nerve fibers to the AVN in 12 dogs during AF. A computer-controlled algorithm adjusted AVN-VS beat by beat to achieve a mean ventricular RR interval of 75%, 100%, 125%, or 150% of spontaneous sinus cycle length. The AVN was then ablated, and the right ventricular (RV) apex was paced either irregularly (i-RVP) using the RR intervals collected during AVN-VS or regularly (r-RVP) at the corresponding mean RR. The results indicated that all 3 strategies improved hemodynamics compared with AF. However, AVN-VS resulted in significantly better responses than either r-RVP or i-RVP. i-RVP resulted in worse hemodynamic responses than r-RVP. The differences among these modes became less significant when mean VR was slowed to 150% of sinus cycle length. CONCLUSIONS: AVN-VS can produce graded slowing of the VR during AF without destroying the AVN. It was hemodynamically superior to AVN ablation with either r-RVP or i-RVP, indicating that the benefits of preserving the physiological antegrade ventricular activation sequence outweigh the detrimental effect of irregularity.

Animals↗

Slow rate during AF improves ventricular performance by reducing sensitivity to cycle length irregularity.

Atrial fibrillation (AF) is characterized by short and irregular ventricular cycle lengths (VCL). While the beneficial effects of heart rate slowing (i.e., the prolongation of VCL) in AF are well recognized, little is known about the impact of irregularity. In 10 anesthetized dogs, R-R intervals, left ventricular (LV) pressure, and aortic flow were collected for >500 beats during fast AF and when the average VCL was prolonged to 75%, 100%, and 125% of the intrinsic sinus cycle length by selective atrioventricular (AV) nodal vagal stimulation. We used the ratio of the preceding and prepreceding R-R intervals (RR(p)/RR(pp)) as an index of cycle length irregularity and assessed its effects on the maximum LV power, the minimum of the first derivative of LV pressure, and the time constant of relaxation by using nonlinear fitting with monoexponential functions. During prolongation of VCL, there was a pronounced decrease in curvature with the formation of a plateau, indicating a lesser dependence on RR(p)/RR(pp). We conclude that prolongation of the VCL during AF reduces the sensitivity of the LV performance parameters to irregularity.

Animals↗

Nonexcitatory stimulus delivery improves left ventricular function in hearts with left bundle branch block.

INTRODUCTION: Preliminary data in a heart failure animal model and isolated muscle preparation have suggested that nonexcitatory stimulation (NES) improves left ventricular (LV) function. METHODS AND RESULTS: We compared biventricular (BV) pacing with NES in an animal model with left bundle branch block (LBBB). The left bundle branch (LBB) was ablated in eight normal heart pigs and led to >50% increase in QRS duration (mean 100 +/- 15 msec). End-diastolic LV pressure, end-systolic LV pressure, LV pressure (LV dP/dtmax), aortic pulse pressure, and LV ejection fraction were measured before pre-LBB ablation and compared with post-LBB ablation (AAI pacing), BV pacing, NES delivery, and BV+NES. Moreover, to evaluate LV diastolic function, we measured the early (E wave) and late flows (A wave) through the mitral valve using spectral Doppler. Compared with post-LBB ablation, NES led to a significant increase in LV dP/dtmax (1,047 +/- 224 mmHg/sec vs 897 +/- 116 mmHg/sec; P < 0.05), LV ejection fraction (64% +/- 18% vs 49% +/- 17%; P < 0.05), and aortic pulse pressure (18 +/- 3.6 mmHg vs 16 +/- 2.8 mmHg; P < 0.05). Moreover, improvement in LV hemodynamic parameters was significantly higher during NES delivery when compared with BV pacing. No significant changes in E wave, A wave, and E/A were recorded during NES, NES+BV, and BV pacing. CONCLUSION: Our preliminary data demonstrate that NES is superior to BV pacing in improving LV function in an animal model with LBBB. Moreover, we demonstrated that NES does not affect transmitral valve flow and subsequently LV diastolic function.

Animals↗

Optimal ventricular rate slowing during atrial fibrillation by feedback AV nodal-selective vagal stimulation.

Although the beneficial effects of ventricular rate (VR) slowing during atrial fibrillation (AF) are axiomatic, the precise relationship between VR and hemodynamics has not been determined. We hypothesized that selective atrioventricular node (AVN) vagal stimulation (AVN-VS) by varying the nerve stimulation intensity could achieve precise graded slowing and permit evaluation of an optimal VR during AF. The aims of the present study were the following: 1) to develop a method for computerized vagally controlled VR slowing during AF, 2) to determine the hemodynamic changes at each level of VR slowing, and 3) to establish the optimal anterograde VR during AF. AVN-VS was delivered to the epicardial fat pad that projects parasympathetic nerve fibers to the AVN in 14 dogs. Four target average VR levels, corresponding to 75%, 100%, 125%, and 150% of the sinus cycle length (SCL), were achieved by computer feedback algorithm. VR slowing resulted in improved hemodynamics and polynomial fit analysis found an optimum for the cardiac output at VR slowing of 87% SCL. We conclude that this novel method can be used to maintain slow anterograde conduction with best hemodynamics during AF.

Animals↗