PubMed Health⌕ Search

Biomedical subjects

Shaoying Kang

Publications and source records attributed to Shaoying Kang.

2 recordsLinked to original sources

Liquid-phase microextraction combined with high-performance liquid chromatography for the determination of local anaesthetics in human urine.

A simple liquid-phase microextraction (LPME) device combined with high-performance liquid chromatography (HPLC) is presented for the simultaneous analysis of local anaesthetics, lidocaine, bupivacaine, and tetracaine, from human urine sample. An organic solvent showed good compatibility with the mobile phase of the HPLC, o-dibutyl phthalate, was selected. Local anaesthetics are extracted from 6 ml of the feed aqueous solution and human urine sample into a water-immiscible organic solvent suspended at the needle tip of the microsyringe, then the organic solvent was directly introduced to a reversed-phase HPLC system. The kind of the organic extraction solvent, the stirring rate, the pH value of the aqueous feed solution, and the extraction time have been discussed. Under the optimized extraction conditions, high enrichment factors (more than 86.0-fold) and significant sample clean-up for all of studied local anaesthetics were achieved within 30 min. The detection limits (lower than 0.05 microg/ml) were comparable with previously reported gas chromatography methods. This method was applied to specimen of patient who was treated with extradural anaesthesia of lidocaine, bupivacaine, and tetracaine, and revealed that simultaneous determination of above three local anaesthetics in human urine was possible.

Anesthetics, Local↗

[Determination of sildenafil and vardenafil in human plasma by high performance liquid chromatography coupled with liquid-liquid-liquid microextraction].

High performance liquid chromatography coupled with liquid-liquid-liquid microextraction was developed for the simultaneous determination of sildenafil and vardenafil in human plasma. The effects of extraction solvent, the volume of organic solvent, dropsize of acceptor phase, stirring rate and extraction time on the enrichment factors of analytes were investigated. The optimized experimental conditions, 300 microL toluene as the organic phase, 2 microL 0.2 mol/L HCl as the acceptor phase, 600 r/min of the stirring rate, and 40 min of the extraction time, were gotten. Under these conditions, high enrichment factors were obtained. The linear range of studied analytes was from 5 microg/L to 1.0 mg/L. The relative standard deviation was lower than 5%. The limits of detection were 1 microg/L for sildenafil and 0.5 microg/L for vardenafil at signal-to-noise ratio of 3. The method with little solvent consumption may provide high analyte preconcentration and excellent sample clean-up, and it is a sensitive and suitable method for simultaneous determination of the above two substances in human plasma.

Chemical Fractionation↗