Induced current bio-impedance technique for monitoring bone mineral density--a simulation model.

In this study, the feasibility of using induced current bio-impedance technique as a method to determine and monitor bone mineral density (BMD) was theoretically evaluated using computerized simulation model. A 2D polar coordinates numerical solver was developed using the Finite Volume Method (FVM) in order to simulate the developed potentials over an axial CT cross section of a human thigh. Varying femur BMD were simulated by varying femur relative permittivity values. At the chosen excitation current of 1 ampere at a frequency of 20 kHz, the real component of the surface potential was found to be more sensitive to BMD variation than the imaginary component (3.9 microV g(-1) cm3 compared with 0.174 microV g(-1) cm3). The correlation between varying femur permittivities and the real component of the developed surface potential was found to be quadratic and influenced by the coil geometry and the measuring point location. Measurement sensitivity was improved either by taking the measuring point closer to the femur location or by minimizing the distance between the excitation coil and the femur. These results provide the basic principle that may enable a future use of bio-impedance technique for bone density evaluation and monitoring.

Animals↗

Contactless bio-impedance monitoring technique for brain cryosurgery in a 3D head model.

A contactless induced-current bio-impedance system for monitoring brain cryosurgery procedure was modeled and numerically simulated, where the excitation coil was also performing as the measuring, or pick-up coil. A segmented three-dimensional (3D) MRI database was used for building the volume conductor geometry, and the numerical finite-volume method was employed for solving the forward problem for calculating the scalar potential distribution and the second-order voltage change on the pick-up coil. Several coil configurations were considered, varying in their relative positioning to the 3D head model. For each case, the sensitivity of the measured voltage change on the excitation coil to the volume of a frozen lesion was calculated. The highest sensitivity (1.1 x 10(-5) relative voltage change per mm3 of frozen tissue) was obtained for a coil arrangement where its closest segment to the volume conductor is at the maximum distance away from the frozen region position. The simulated system signal-to-carrier ratio was O(10(-8)).

Brain↗

Induced current bio-impedance technique for monitoring cryosurgery procedure in a two-dimensional head model using generalized coordinate systems.

In the noninvasive bio-impedance technique, small amplitude currents are applied to the body and the developing potentials on its surface are measured. This noninvasive technique is used to monitor physiological and pathological processes, which alter the values or the spatial distribution of the electrical impedance inside the human body. A possible application of the bio-impedance technique is monitoring brain cryosurgery procedure--a surgical technique that employs freezing to destroy undesirable tissues. A numerical solver was developed to evaluate the ability of an induced-current bio-impedance system to monitor the growth of the frozen tissue inside the head in simulation. The forward-problem bio-impedance solver, which is based on the finite volume method in generalized two-dimensional (2-D) coordinate systems, was validated by a comparison to a known analytical solution for body-fitted and Cartesian meshing grids. The sensitivity of the developed surface potential to the ice-ball area was examined using a 2-D head model geometry, and was found to range between 0.8 x 10(-2) and 1.68 x 10(-2) (relative potential difference/mm2), depending on the relative positioning of the excitation coil and the head. The maximal sensitivity was achieved when the coil was located at the geometrical center of the model.

Animals↗

Induced current electrical impedance tomography system: experimental results and numerical simulations.

In electrical impedance tomography (EIT), measurements of developed surface potentials due to applied currents are used for the reconstruction of the conductivity distribution. Practical implementation of EIT systems is known to be problematic due to the high sensitivity to noise of such systems, leading to a poor imaging quality. In the present study, the performance of an induced current EIT (ICEIT) system, where eddy current is applied using magnetic induction, was studied by comparing the voltage measurements to simulated data, and examining the imaging quality with respect to simulated reconstructions for several phantom configurations. A 3-coil, 32-electrode ICEIT system was built, and an iterative modified Newton-Raphson algorithm was developed for the solution of the inverse problem. The RMS norm between the simulated and the experimental voltages was found to be 0.08 +/- 0.05 mV (<3%). Two regularization methods were implemented and compared: the Marquardt regularization and the Laplacian regularization (a bounded second-derivative regularization). While the Laplacian regularization method was found to be preferred for simulated data, it resulted in distinctive spatial artifacts for measured data. The experimental reconstructed images were found to be indicative of the angular positioning of the conductivity perturbations, though the radial sensitivity was low, especially when using the Marquardt regularization method.

Algorithms↗

Induced-current electrical impedance tomography: a 2-D theoretical simulation.

A reconstruction algorithm, based on the modified Newton-Raphson algorithm, was developed for induced-current electrical impedance tomography and studied in theoretical two-dimensional geometry representing a human thorax. The finite-volume method was applied for the discretization of the physical domain, resulting in a symbolic representation of the Jacobian matrix, which is accurate and fast to construct. Several system configurations, differing in the number of excitation coils and electrodes, were simulated, and the performance in thoracic imaging was studied. It was found that a six-coil system shows a significant 40% improvement of conductivity values reconstruction over the three-coil system (an error of 2.06 omega(-1) compared with 3.44 omega(-1)). A number of 32 electrodes was found to be sufficient, being the smallest number of electrodes to still provide a reasonable performance (only 4.2% degradation in average conductivity error compared with the maximum possible 106-electrode system).

Algorithms↗

Validation of vital signs recorded via a new telecare system.

A telecare system (Medic4All) has been developed that relies on a wireless wristwatch-like sensor to measure the pulse wave from the radial artery. From this, the heart rate and respiration rate are derived. The system's performance was examined by comparing the results obtained from the pulse wave signal with those obtained from conventional electrocardiographic and spirometer devices. A total of 144 patients participated in the study; their mean (SD) age was 43 (18) years. There were 44 cardiac patients in group 1 and 100 healthy patients, who were studied in their homes, in group 2. There was a significant correlation between the heart rates measured by the two monitoring methods. A 'difference versus average' analysis showed that the error distribution had a mean (SD) value of -0.1 (3.3) beats/min. Similarly, the respiration rates measured by the two techniques were significantly correlated. The error distribution had a mean (SD) value of 0.1 (1.9) respirations/min. The present study suggests that the wrist-worn sensor represents a promising tool for online detection and monitoring of vital signs in the home.

Adult↗

Induced current impedance technique for monitoring brain cryosurgery in a two-dimensional model of the head.

A fast and robust finite volume solver of the two-dimensional induced current electrical impedance forward problem was developed. The numerical solver was validated by comparison with an existing analytical solution for a symmetrical geometry case, showing an accuracy of 0.07%. The solver was used to theoretically examine the sensitivity of the induced current impedance technique for the medical procedure of monitoring brain cryosurgery. The simulation was performed using a two-dimensional approximation of otherwise realistic geometry model of the head with different ice-ball sizes, simulating the expansion of the frozen lesion. The sensitivity of the scalp potential to the ice-ball size was found to be 53 x 10(-4) (relative scalp potential mm(-2)).

Biomedical Engineering↗

Monitoring lung resistivity changes in congestive heart failure patients using the bioimpedance technique.

The feasibility of a novel, dedicated system for monitoring lung resistivity in congestive heart failure patients, implementing a hybrid approach of the bioimpedance technique, was assessed in this preliminary study. Thirty-three healthy volunteers and 34 congestive heart failure patients were measured with the PulmoTrace system (CardioInspect, Tel Aviv University, Tel Aviv, Israel) during tidal respiration, and the ability to monitor the respective lung resistivity values was assessed. Mean left and right lung resistivity values of 1205+/-163 and 1200+/-165 ohm.cm for the control group and 888+/-193 and 943+/-187 ohm.cm for the congestive heart failure group were found, indicating a significant (p<2.10(-7)) difference between the two groups. The results of long-term monitoring of two patients during medical treatment are also shown. This hybrid approach system is believed to improve diagnostic capabilities and help physicians to better adjust medication dosage on a frequent basis.

Aged↗