High power universal piezoelectric transformer.

This study describes a multilayer piezoelectric voltage and power transformer that has one direction poling, operates in a wide-frequency range and delivers both step-up and step-down voltages by inverting the electrical connections. In this design, the input and output electrodes are on the same side of the disk and are isolated from each other by a fixed isolation gap. The electrode pattern is a ring/dot structure such that it uses radial mode for both input and output part that are built-in on the same ceramic disk. A prototype transformer was fabricated of size 15 x 2.78 mm2 having mass of 3.8 gm. In the step-down configuration at the constant output power of 6 W, the transformer characteristics across a 100 omega load were found to be efficiency = 92%, gain = 0.21 input voltage = 110 V(rms), and temperature rise = 20 degrees C from the room temperature. In the step-up configuration at the constant output power of 5 W, the transformer characteristics across a 5 komega load were found to be efficiency = 97%, gain = 9.5, input voltage = 16 V(rms), and temperature rise = 8 degrees C from the room temperature. A detailed equivalent circuit analysis of the transformer was done, and the results were found to be in excellent agreement with the experimental results.

Journal Article↗

Electric energy generator.

This study reports an extremely cost-effective mechanism for converting wind energy into electric energy using piezoelectric bimorph actuators at small scale. The total dimensions of the electric energy generator are 5.08 x 11.6 x 7.7 cm3. The rectangular, box-shaped body of the overall structure is made using 3.2-mm thick plastic. Slits are made on two opposite faces of the box so that two columns and six rows of bimorph actuators can be inserted. Each row of bimorph actuators is separated from each other by a gap of 6 mm, and the two columns of bimorphs are separated from each other by a gap of 6.35 mm. In between the two columns, a cylindrical rod is inserted consisting of six rectangular hooks. The hooks are positioned in such a way that each of them just touches the two bimorphs on either side in a particular row. As the wind flows across the generator, it creates a rotary motion on the attached fan that is converted into vertical motion of the cylindrical rod using the cam-shaft mechanism. This vertical motion of the cylindrical rod creates oscillating stress on the bimorphs due to attached hooks. The bimorphs produce output voltage proportional to the applied oscillating stress through piezoelectric effect. The prototype fabricated in this study was found to generate 1.2 mW power at a wind speed of 12 mph across the load of 1.7 komega.

Letter↗

High power universal piezoelectric transformer.

This study describes a multilayer piezoelectric voltage and power transformer that has one direction poling, operates in a wide-frequency range and delivers both step-up and step-down voltages by inverting the electrical connections. In this design, the input and output electrodes are on the same side of the disk and are isolated from each other by a fixed isolation gap. The electrode pattern is a ring/dot structure such that it uses radial mode for both input and output part that are built-in on the same ceramic disk. A prototype transformer was fabricated of size 15 x 2.78 mm2 having mass of 3.8 gm. In the step-down configuration at the constant output power of 6 W, the transformer characteristics across a 100 ohms load were found to be efficiency = 92%, gain = 0.21 input voltage = 110 Vrms, and temperature rise = 20 degrees C from the room temperature. In the step-up configuration at the constant output power of 5 W, the transformer characteristics across a 5 kohms load were found to be efficiency = 97%, gain = 9.5, input voltage = 16 Vrms, and temperature rise = 8 degrees C from the room temperature. A detailed equivalent circuit analysis of the transformer was done, and the results were found to be in excellent agreement with the experimental results.

Corrected and Republished Article↗