PubMed Health⌕ Search

Biomedical subjects

Shehzad Naroo

Publications and source records attributed to Shehzad Naroo.

5 recordsLinked to original sources

The AS biometry technique--a novel technique to aid accurate intraocular lens power calculation after corneal laser refractive surgery.

Intraocular lens power (IOL) calculation for cataract surgery has been shown to be inaccurate after photorefractive keratectomy (PRK), laser-assisted subepithelial keratectomy (LASEK) and laser in situ keratomileusis (LASIK). Many techniques exist to calculate corneal power with varying results and require the clinician to be aware of the pitfalls of IOL power calculation in post-refractive eyes. The AS biometry method proposed here is a simple method which does not rely on the calculation of corneal power. This new method is compared to the current gold standard the clinical history method (CHM). Twenty-nine eyes of 15 patients had routine biometry prior to LASIK, LASEK or PRK. The range of pre-operative spherical equivalent refractive error was -5.37 to +4.00 diopters. The post-operative refraction was measured at 3-6 months. The IOL power calculation was calculated using the AS biometry method and the CHM. The two methods were compared using the Student's paired t-test and the Bland Altman technique. There was no statistical difference between the AS biometry method and the CHM. The paired Student's t-test comparing the AS biometry method and the CHM showed no statistical difference, t=0.33 with a p-value of 0.75, at a 95% confidence interval. The authors conclude that the AS biometry technique is as accurate as the CHM. The former is a simpler method which avoids many of the pitfalls and confounding factors involved in IOL power calculation following corneal excimer laser surgery. However, like the CHM it requires measurements prior to laser surgery.

Adult↗

Objective accommodative amplitude and dynamics with the 1CU accommodative intraocular lens.

PURPOSE: To compare the objective accommodative amplitude and dynamics of eyes implanted with the one-compartment-unit (1CU; HumanOptics AG, Erlangen, Germany) accommodative intraocular lenses (IOLs) with that measured subjectively. METHODS: Twenty eyes with a 1CU accommodative IOL implanted were refracted and distance and near acuity measured with a logMAR (logarithm of the minimum angle of resolution) chart. The objective accommodative stimulus-response curve for static targets between 0.17 and 4.00 D accommodative demand was measured with the SRW-5000 (Shin-Nippon Commerce Inc., Tokyo, Japan) and PowerRefractor (PlusOptiX, Nürnberg, Germany) autorefractors. Continuous objective recording of dynamic accommodation was measured with the SRW-5000, with the subject viewing a target moving from 0 to 2.50 D at 0.3 Hz through a Badal lens system. Wavefront aberrometry measures (Zywave; Bausch & Lomb, Rochester, NY) were made through undilated pupils. Subjective amplitude of accommodation was measured with the RAF (Royal Air Force accommodation and vergence measurement) rule. RESULTS: Four months after implantation best-corrected acuity was -0.01 +/- 0.16 logMAR at distance and 0.60 +/- 0.09 logMAR at near. Objectively, the static amplitude of accommodation was 0.72 +/- 0.38 D. The average dynamic amplitude of accommodation was 0.71 +/- 0.47 D, with a lag behind the target of 0.50 +/- 0.48 seconds. Aberrometry showed a decrease in power of the lens-eye combination from the center to the periphery in all subjects (on average, -0.38 +/- 0.28 D/mm). Subjective amplitude of accommodation was 2.24 +/- 0.42 D. Two years after 1CU implantation, refractive error and distance visual acuity remained relatively stable, but near visual acuity, and the subjective and objective amplitudes of accommodation decreased. CONCLUSIONS: The objective accommodating effects of the 1CU lens appear to be limited, although patients are able to track a moving target. Subjective and objective accommodation was reduced at the 2-year follow-up. The greater subjective amplitude of accommodation is likely to result from the eye's depth of focus of and the aspheric nature of the IOL.

Accommodation, Ocular↗

Editorial.

Explore the source record for details and available documents.

Humans↗

Scotopic measurement of normal pupil size with the Colvard pupillometer and the Nidek auto-refractor.

PURPOSE: To compare prospectively, pupil size with the Nidek AR700A auto-refractor and the Colvard pupillometer. METHODS: Pupil diameter was measured in 46 eyes at 2 min intervals in a low mesopic and under photopic light conditions. RESULTS: The mean pupil diameter was 4.8+/-1.0mm with the Colvard pupillometer and 4.8+/-0.9mm with the Nidek auto-refractor in low mesopic light conditions. The mean photopic pupil diameter was 3.3+/-0.8mm with the Colvard pupillometer and 3.9+/-0.8mm with the Nidek auto-refractor. CONCLUSION: The pupil sizes are very similar with both instruments.

Adult↗

Nidek OPD-scan analysis of normal, keratoconic, and penetrating keratoplasty eyes.

PURPOSE: To determine by wavefront analysis the difference between eyes considered normal, eyes diagnosed with keratoconus, and eyes that have undergone penetrating keratoplasty METHODS: The Nidek OPD-Scan wavefront aberrometer was used to measure ocular aberrations out to the sixth Zernike order. One hundred and thirty eyes that were free of ocular pathology, 41 eyes diagnosed with keratoconus, and 8 eyes that had undergone penetrating keratoplasty were compared for differences in root mean square value. Three and five millimeter root mean square values of the refractive power aberrometry maps of the three classes of eyes were compared. Radially symmetric and irregular higher order aberration values were compared for differences in magnitude. RESULTS: Root mean square values were lower in eyes free of ocular pathology compared to eyes with keratoconus and eyes that had undergone penetrating keratoplasty. The aberrations were larger with the 5-mm pupil. Coma and spherical aberration values were lower in normal eyes. CONCLUSION: Wavefront aberrometry of normal, pathological, and eyes after surgery may help to explain the visual distortions encountered by patients. The ability to measure highly aberrated eyes allows an objective assessment of the optical consequences of ocular pathology and surgery. The Nidek OPD-Scan can be used in areas other than refractive surgery.

Corneal Topography↗