PubMed Health⌕ Search

Biomedical subjects

Shelton D Caruthers

Publications and source records attributed to Shelton D Caruthers.

At least 19 recordsLinked to original sources

Endothelial alpha(v)beta3 integrin-targeted fumagillin nanoparticles inhibit angiogenesis in atherosclerosis.

OBJECTIVE: Angiogenic expansion of the vasa vasorum is a well-known feature of progressive atherosclerosis, suggesting that antiangiogenic therapies may stabilize or regress plaques. Alpha(v)beta3 integrin-targeted paramagnetic nanoparticles were prepared for noninvasive assessment of angiogenesis in early atherosclerosis, for site-specific delivery of antiangiogenic drug, and for quantitative follow-up of response. METHODS AND RESULTS: Expression of alpha(v)beta3 integrin by vasa vasorum was imaged at 1.5 T in cholesterol-fed rabbit aortas using integrin-targeted paramagnetic nanoparticles that incorporated fumagillin at 0 microg/kg or 30 microg/kg. Both formulations produced similar MRI signal enhancement (16.7%+/-1.1%) when integrated across all aortic slices from the renal arteries to the diaphragm. Seven days after this single treatment, integrin-targeted paramagnetic nanoparticles were readministered and showed decreased MRI enhancement among fumagillin-treated rabbits (2.9%+/-1.6%) but not in untreated rabbits (18.1%+/-2.1%). In a third group of rabbits, nontargeted fumagillin nanoparticles did not alter vascular alpha(v)beta3-integrin expression (12.4%+/-0.9%; P>0.05) versus the no-drug control. In a second study focused on microscopic changes, fewer microvessels in the fumagillin-treated rabbit aorta were counted compared with control rabbits. CONCLUSIONS: This study illustrates the potential of combined molecular imaging and drug delivery with targeted nanoparticles to noninvasively define atherosclerotic burden, to deliver effective targeted drug at a fraction of previous levels, and to quantify local response to treatment.

Angiogenesis Inhibitors↗

Targeted PARACEST nanoparticle contrast agent for the detection of fibrin.

A lipid-encapsulated perfluorocarbon nanoparticle molecular imaging contrast agent that utilizes a paramagnetic chemical exchange saturation transfer (PARACEST) chelate is presented. PARACEST agents are ideally suited for molecular imaging applications because one can switch the contrast on and off at will simply by adjusting the pulse sequence parameters. This obviates the need for pre- and postinjection images to define contrast agent binding. Spectroscopy (4.7T) of PARACEST nanoparticles revealed a bound water peak at 52 ppm, in agreement with results from the water-soluble chelate. Imaging of control nanoparticles showed no appreciable contrast, while PARACEST nanoparticles produced >10% signal enhancement. PARACEST nanoparticles were targeted to clots via antifibrin antibodies and produced a contrast-to-noise ratio (CNR) of 10 at the clot surface.

Contrast Media↗

Molecular imaging by MRI.

The goal of molecular imaging is to detect pathologic biomarkers, which can lead to early recognition of diseases, better therapeutic management, and improved monitoring for recurrence. MRI is a particularly attractive method for molecular imaging applications, due to its noninvasive nature, outstanding signal to noise ratio, high spatial resolution, exceptional tissue contrast, and short imaging times. Site-specific MRI contrast agents have been developed to target biologic processes that occur early in the development of atherosclerotic plaques, including angiogenesis and lipid accumulation, or biosignatures that appear later, such as fibrin and tissue factor resulting from plaque rupture. Moreover, targeted contrast agents can also serve as drug delivery vehicles, combining diagnosis and therapy. If ultimately successful, these emerging molecular imaging agents and techniques will allow early disease recognition and quantification prompting therapeutic intervention before serious sequelae ensue.

Antibiotics, Antineoplastic↗

High-resolution MR imaging of the human eye 2005.

RATIONALE AND OBJECTIVES: We studied preparatory strategies for high-resolution human eye in vivo imaging with commercially available magnets and coils. MATERIALS AND METHODS: We imaged normal volunteers on 1.5T systems by Philips, GE, and Siemens, using commercial approximately 9 cm temporomandibular joint receive coils. Subjects fixated the nonimaged eye on a target. We compared signal (S) to tissue noise (Nt) and system noise (Ns) between images acquired with the imaged eye: 1) open, 2) held closed, 3) taped closed, and 4) taped closed with overlying water-soaked gauze. We standardized technique 4 to compare studies between manufacturers using T1-weighted parameters (repetition time/echo time/flip angle/number of signal averages = 400 ms/10-17 ms/90 degrees /4-6, in-plane resolution approximately 250 x 250 microm2; 2-3 mm slices, image time = 4.3-5.2 min). We obtained similar images of an enucleated human eye to estimate in vivo effects of microsaccades and ocular pulsations. RESULTS: Measurements of S/Nt and S/Ns gave surprising results of Nt < Ns in some instances. Ns/Nt was congruent with 1, varying approximately 20%, when the eye was taped shut and covered with water-soaked gauze. T1-weighted spin echo sequences, using technique 4, produced high-quality images with good S/Nt on all systems. Images from the three manufacturers were comparable when parameters were normalized for pulse repetition time, echo time, number of signal averages, bandwidth in Hz/pixel, and reconstruction matrix. Images of the enucleated eye produced S/Nt ratios that were comparable to in vivo images in some structures. CONCLUSIONS: Our best preparatory technique produced images with in-plane resolution of approximately 250 mum in 4-5 minutes with three commercial 1.5 T systems. The in vivo S/Nt was comparable to in vitro values in most solid tissues but decreased in most fluid compartments.

Eye↗

Efficacy and safety of right and left atrial ablations on the beating heart with irrigated bipolar radiofrequency energy: a long-term animal study.

OBJECTIVE: The Cox maze procedure is the most effective surgical treatment for atrial fibrillation; however, its complexity has limited its clinical utility. The purpose of this study was to simplify the procedure by using an irrigated bipolar radiofrequency ablation device on the beating heart without cardiopulmonary bypass. METHODS: Six domestic pigs underwent median sternotomy. The pulmonary veins were circumferentially ablated. Electrical isolation was confirmed by pacing. Eight lesions were performed epicardially, and three lesions were performed through purse-string sutures with one of the jaws of the device introduced into the right atrium. After 30 days, magnetic resonance imaging was performed to assess atrial function, pulmonary vein anatomy, and coronary artery patency. Cholinergic stimulation and burst pacing were administered to induce atrial fibrillation. Histologic assessment of the heart was performed after the animal was killed. RESULTS: A modified Cox maze procedure was successfully performed with the irrigated bipolar radiofrequency device with no deaths. In every instance, the pulmonary veins were electrically isolated. Cholinergic stimulation with burst pacing failed to produce atrial fibrillation. Imaging studies revealed tricuspid regurgitation without evidence of pulmonary vein stenosis, coronary artery stenosis, or intra-atrial thrombus. Total atrial ejection fraction was 16.9% +/- 7.5%, a significant reduction. Histologically, 99% of the lesions were transmural, and there was no evidence of coronary sinus injury. CONCLUSION: Lesions on both the right and left atria can be created successfully on the beating heart with irrigated bipolar radiofrequency. The great majority of lesions with this device were transmural. This device should not be used on valvular tissue.

Animals↗

MR three-dimensional molecular imaging of intramural biomarkers with targeted nanoparticles.

In this study, porcine carotid arteries were subjected to balloon overstretch injury followed by local delivery of paramagnetic nanoparticles targeted to alphavbeta3-integrin expressed by smooth muscle cells or collagen III within the extracellular matrix. Carotid T1-weighted angiography and vascular imaging was performed at 1.5T. While MR angiograms were indistinguishable between control and targeted vessel segments, alphavbeta3-integrin-and collagen Ill-targeted nanoparticles spatially delineated patterns and volumes of stretch injury. In conclusion, MR molecular imaging with alphavbeta3-integrin or collagen Ill-targeted nanoparticles enables the non-invasive, three-dimensional characterization of arterial pathology unanticipated from routine angiography.

Animals↗

In vitro demonstration using 19F magnetic resonance to augment molecular imaging with paramagnetic perfluorocarbon nanoparticles at 1.5 Tesla.

OBJECTIVES: This study explored the use of F spectroscopy and imaging with targeted perfluorocarbon nanoparticles for the simultaneous identification of multiple bio-signatures at 1.5 T. MATERIALS AND METHODS: Two nanoparticle emulsions with perfluoro-15-crown-5-ether (CE) or perfluorooctylbromide (PFOB) cores were targeted in vitro to fibrin clot phantoms (n=12) in 4 progressive ratios using biotin-avidin interactions. The CE nanoparticles incorporated gadolinium. Fluorine images were acquired using steady-state gradient-echo techniques; spectra using volume-selective and nonselective sampling. RESULTS: On conventional T1-weighted imaging, clots with CE nanoparticles enhanced as expected, with intensity decreasing monotonically with CE concentration. All clots were visualized using wide bandwidth fluorine imaging, while restricted bandwidth excitation permitted independent imaging of CE or PFOB nanoparticles. Furthermore, F imaging and spectroscopy allowed visual and quantitative confirmation of relative perfluorocarbon nanoparticle distributions. CONCLUSIONS: F MRI/S molecular imaging of perfluorocarbon nanoparticles in vitro suggests that noninvasive phenotypic characterization of pathologic bio-signatures is feasible at clinical field strengths.

Animals↗

Demonstration of an anterior diffusional pathway for solutes in the normal human eye with high spatial resolution contrast-enhanced dynamic MR imaging.

PURPOSE: The present studies were conducted to determine whether a diffusional pathway for solutes exists from the ciliary body stroma to the anterior chamber of the human eye. The existence of such a pathway has been demonstrated in rabbits and monkeys, but such a pathway in humans would necessitate a shift in the physiological paradigm of the blood-aqueous barrier. METHODS: Seven normal human volunteers (five men, two women; age range, 27 to 59 years) underwent nine dynamic T1-weighted, spin-echo MR imaging studies, using intravenous, gadolinium-based contrast agents. RESULTS: In all cases, signal intensity rose rapidly in the ciliary body. In all subjects, there was a measurable latent rise in signal strength (enhancement) in the anterior chamber. Signal enhancement typically occurred in the angle of the anterior chamber earlier, and to a greater degree, than within the center of the chamber. Increased signal within the posterior chamber was significantly less than in the anterior chamber, with measured increases probably attributable to volume averaging. CONCLUSIONS: These findings are consistent with the existence of an anterior diffusional pathway in the human eye. The model warrants further testing.

Adult↗

Targeted magnetic resonance imaging contrast agents.

The era of personalized medicine is emerging as physicians attempt to diagnose disease in asymptomatic individuals and treat pathology early in its natural history. A novel tool in an emerging armamentarium, molecular imaging will allow noninvasive characterization and segmentation of patients for delivering custom-tailored therapy. Nanoparticulate agents, such as superparamagnetic agents, liposomes, perfluorocarbon nanoparticle emulsions, and dendrimers, are being intensively researched as formulation platforms for various targeted clinical applications. As exemplified by perfluorocarbon nanoparticles, these new agents, in combination with the rapid innovations in imaging hardware and software, will allow the emergence of new medical diagnostic and therapeutic paradigms.

Contrast Media↗

Paradoxical increase in ventricular torsion and systolic torsion rate in type I diabetic patients under tight glycemic control.

OBJECTIVES: This study sought to characterize the early features of diabetic cardiomyopathy by magnetic resonance imaging (MRI) tagging. BACKGROUND: The earliest manifestations of diabetic cardiomyopathy have not been well established, especially under tight glycemic management. We hypothesized that torsion measurements would identify subclinical contractile alterations in type I diabetics with normal left ventricular ejection fraction, mass, blood pressure, and aggressive glycemic control. We also sought to characterize the influence of elevated resting heart rates (HRs) of diabetics on torsion. METHODS: Sixteen patients with type I diabetes and 10 control patients underwent cine and tagged MRI with a 1.5-T scanner. Torsion, strain, and their rates were measured. To quantify the influence of chronotropic and inotropic stimulation on torsion, nine healthy volunteers underwent MRI tagging at rest, after atropine injection, and after exercise. RESULTS: Diabetic patients (hemoglobin A1c, 6.8 +/- 0.4%) had a higher resting HR (77.0 +/- 12.4 beats/min vs. 59.0 +/- 5.6 beats/min; p < 0.01), higher maximal torsion by 23% (3.5 +/- 0.9 degrees/cm vs. 2.7 +/- 0.4 degrees/cm; p < 0.01) and higher maximal systolic torsion rate (TR-s) by 25% (0.013 +/- 0.003 degrees/cm/s vs. 0.010 +/- 0.002 degrees/cm/s, p = 0.01). Torsion did not significantly change with chronotropic stimulation (p = 0.30). CONCLUSIONS: In diabetics under tight glycemic control, we observed a surprising increase in torsion and TR-s unrelated to chronotropic influences of HR. We propose that increased torsion and TR-s could represent early predictive markers of the propensity to cardiac dysfunction in asymptomatic type I diabetics. Furthermore, these findings seem fundamental to the diabetic state itself and unaccounted for by other comorbidities.

Adult↗

Molecular MR imaging of melanoma angiogenesis with alphanubeta3-targeted paramagnetic nanoparticles.

Neovascularization is a critical component in the progression of malignant melanoma. The objective of this study was to determine whether alpha(nu)beta(3)-targeted paramagnetic nanoparticles can detect and characterize sparse alpha(nu)beta integrin expression on neovasculature induced by nascent melanoma xenografts ( approximately 30 mm(3)) at 1.5T. Athymic nude mice bearing human melanoma tumors were intravenously injected with alpha(v)beta(3)-integrin-targeted paramagnetic nanoparticles, nontargeted paramagnetic nanoparticles, or alpha(v)beta(3)-targeted-nonparamagnetic nanoparticles 2 hr before they were injected with alpha(v)beta(3)-integrin-targeted paramagnetic nanoparticles (i.e., in vivo competitive blockade) and imaged with MRI. Contrast enhancement of neovascularity in animals that received alpha(nu)beta(3)-targeted paramagnetic nanoparticles increased 173% by 120 min. Signal contrast with nontargeted paramagnetic nanoparticles was approximately 50% less than that in the targeted group (P < 0.05). Molecular MRI results were corroborated by histology. In a competitive cell adhesion assay, incubation of alpha(nu)beta(3)-expressing cells with targeted nanoparticles significantly inhibited binding to a vitronectin-coated surface, confirming the bioactivity of the targeted nanoparticles. The present study lowers the limit previously reported for detecting sparse biomarkers with molecular MRI in vivo. This technique may be employed to noninvasively detect very small regions of angiogenesis associated with nascent melanoma tumors, and to phenotype and stage early melanoma in a clinical setting.

Analysis of Variance↗

Correlation analysis of stenotic aortic valve flow patterns using phase contrast MRI.

Phase contrast MRI is an emerging tool for evaluating valvular pathology. However, the effects of variable image position and valvular pathology on velocity measurements have not been explored. We compare velocity maps with correlation methods, used in image processing to align images and quantify their similarity, to define these effects on calculations of valve orifice area. Quantitative flow images were acquired in four parallel planes (2 in aortic root, 2 in outflow tract), in patients (n = 22) with aortic stenosis. Velocity-time integrals (VTIs) were computed and cross-correlations were performed to quantitatively compare the shapes and relative positions of three-dimensional flow profiles between scans at various positions. Supravalvular VTIs correlated well with one another (R = 0.96), with comparable values. The two subvalvular VTIs exhibited a linear relationship (R = 0.93) but with a 23% difference in mean values. Cross-correlations between supravalvular levels were maximized at (0, 0) offset (indicating concentrically aligned jets) for 19/23 patients, with an average maximum value of 0.957 +/- 0.028; the average for the remainder was 0.800 +/- 0.037. For subvalvular levels, all cross-correlations were maximized at (0, 0) with average maximum 0.968 +/- 0.160. The aortic VTI measurements were comparable, indicating relative insensitivity to the position of the imaging plane; in the LVOT, measurements were only somewhat position-dependent. We conclude that phase contrast MRI is a robust tool for the evaluation of aortic stenosis.

Adult↗

1H/19F magnetic resonance molecular imaging with perfluorocarbon nanoparticles.

Developments in genomics, proteomics, and cell biology are leading a trend toward individualized segmentation and treatment of patients based on early, noninvasive recognition of unique biosignatures. Although developments in molecular imaging have been dominated by nuclear medicine agents in the past, the advent of nanotechnology in the 1990s has led to magnetic resonance (MR) molecular agents that allow detection of sparse biomarkers with a high-resolution imaging modality that can provide both physiological and functional agents. A wide variety of nanoparticulate MR contrast agents have emerged, most of which are superparamagnetic iron oxide-based constructs. However, this chapter focuses on a diagnostic and therapeutic perfluorocarbon (PFC) nanoparticulate platform that is not only effective as a T1-weighted agent, but also supports (19)F MR spectroscopy and imaging. The unique capability of (19)F permits confirmation and segmentation of MR contrast images as well as direct quantification of nanoparticle concentrations within a voxel. PFC nanoparticles have the capability to effectively deliver therapeutic agents to target sites by a novel mechanism termed "contact-facilitated drug delivery." Combined with MR spectroscopy, the concentration of drug delivered to the target site can be determined and the expected response predicted. Moreover, mixtures of nanoparticles with different perfluorocarbon cores can provide a quantitative, multispectral signal, which can be used to simultaneously distinguish the relative concentrations of several important epitopes within a region of interest. In conjunction with rapid improvements in MR imaging, the prospects for personalized medicine and early recognition and treatment of disease have never been better.

Animals↗

Magnetic resonance nanoparticles for cardiovascular molecular imaging and therapy.

Molecular vascular imaging represents a novel tool that promises to change the current medical paradigm of 'see and treat' to a 'detect and prevent' strategy. Nanoparticle agents, such as superparamagnetic nanoparticles and perfluorocarbon nanoparticle emulsions, have been developed for noninvasive imaging, particularly for magnetic resonance imaging. Designed to target specific epitopes in tissues, these agents are beginning to enter clinical trials for cardiovascular applications. The delivery of local therapy with these nanoparticles, using mechanisms such as contact-facilitated drug delivery, is in the advanced stages of preclinical research. Ultimately, combined diagnostic and therapeutic nanoparticle formulations may allow patients to be characterized noninvasively and segmented to receive custom-tailored therapy. This review focuses on recent developments of nanoparticle technologies with an emphasis on cardiovascular applications of magnetic resonance imaging.

Animals↗

Quantification of stenotic mitral valve area with magnetic resonance imaging and comparison with Doppler ultrasound.

OBJECTIVES: The purpose of this study was to evaluate the reliability of the pressure half-time (PHT) method for estimating mitral valve areas (MVAs) by velocity-encoded cardiovascular magnetic resonance (VE-CMR) and to compare the method with paired Doppler ultrasound. BACKGROUND: The pressure half-time Doppler echocardiography method is a practical technique for clinical evaluation of mitral stenosis. As CMR continues evolving as a routine clinical tool, its use for estimating MVA requires thorough evaluation. METHODS: Seventeen patients with mitral stenosis underwent echocardiography and CMR. Using VE-CMR, MVA was estimated by PHT method. Additionally, peak E and peak A velocities were defined. Interobserver repeatability of VE-CMR was evaluated. RESULTS: By Doppler, MVAs ranged from 0.87 to 4.49 cm2; by CMR, 0.91 to 2.70 cm2, correlating well between modalities (r = 0.86). The correlation coefficient for peak E and peak A between modalities was 0.81 and 0.89, respectively. Velocity-encoded CMR data analysis provided robust, repeatable estimates of peak E, peak A, and MVA (r = 0.99, 0.99, and 0.96, respectively). CONCLUSIONS: Velocity-encoded cardiovascular magnetic resonance can be used routinely as a robust tool to quantify MVA via mitral flow velocity analysis with PHT method.

Aged↗

Targeted nanoparticles for quantitative imaging of sparse molecular epitopes with MRI.

Before molecular imaging with MRI can be applied clinically, certain problems, such as the potential sparseness of molecular epitopes on targeted cell surfaces, and the relative weakness of conventional targeted MR contrast agents, must be overcome. Accordingly, the conditions for diagnostic conspicuity that apply to any paramagnetic MRI contrast agent with known intrinsic relaxivity were examined in this study. A highly potent paramagnetic liquid perfluorocarbon nanoparticle contrast agent ( approximately 250 nm diameter, >90,000 Gd3+/particle) was imaged at 1.5 T and used to successfully predict a range of sparse concentrations in experimental phantoms with the use of standard MR signal models. Additionally, we cultured and targeted the smooth muscle cell (SMC) monolayers that express "tissue factor," a glycoprotein of crucial significance to hemostasis and response to vascular injury, by conjugating an anti-tissue factor antibody fragment to the nanoparticles to effect specific binding. Quantification of the signal from cell monolayers imaged at 1.5 T demonstrated, as predicted via modeling, that only picomolar concentrations of paramagnetic perfluorocarbon nanoparticles were required for the detection and quantification of tissue factor at clinical field strengths. Thus, for targeted paramagnetic agents carrying high payloads of gadolinium, it is possible to quantify molecular epitopes present in picomolar concentrations in single cells with routine MRI.

Analysis of Variance↗

Clinical utility of rapid prescreening magnetic resonance angiography of peripheral vascular disease prior to cardiac catheterization.

PURPOSE: The presence of peripheral vascular disease, in particular iliofemoral disease, is responsible in part for vascular complications from femoral artery cannulation. We investigated whether prescreening for vascular obstructions with magnetic resonance angiography (MRA) in high-risk patients with peripheral vascular disease (PVD) would provide useful information to angiographers seeking to improve the safety and efficiency of femoral artery access at cardiac catheterization. METHODS: Twelve consecutive patients with known or suspected PVD underwent contrast-enhanced, aorto-iliofemoral MRA using a real-time BolusTrak technique. Contrast-to-noise ratios for each patient were calculated. The cardiac angiographer reviewed the MRA prior to catheterization and selected an access site. The patients' subsequent clinical course was evaluated, and a postprocedure questionnaire was completed by the angiographer to define the value of the prescreening MRA. RESULTS: No significant vascular complications occurred in these patients as defined by failure of initially chosen access site, arterial dissection, limb ischemia, pseudoaneurysm formation, hemorrhage (including retroperitoneal hematoma), or need for blood transfusion or emergency vascular surgical repair. Statistical frequency analysis of the responses in the postprocedure questionnaire demonstrated that the MR data were clinically valuable in (1) influencing the initial choice of access site; (2) influencing technical alterations to the standard access; and, (3) enhancing confidence in the selection of access site. CONCLUSIONS: MRA prescreening in patients with PVD is an effective, novel adjunct to cardiac catheterization in selected patients that improves physician confidence and influences technical choices during coronary angiography from the femoral artery approach.

Adult↗