PubMed Health⌕ Search

Biomedical subjects

Sheng Ping Wu

Publications and source records attributed to Sheng Ping Wu.

2 recordsLinked to original sources

Wall shear rates differ between the normal carotid, femoral, and brachial arteries: an in vivo MRI study.

PURPOSE: To investigate wall shear rates in vivo in the common carotid, brachial, and superficial femoral arteries using very high resolution magnetic resonance imaging (MRI) phase contrast measurements. MATERIALS AND METHODS: Mean, maximum, and minimum wall shear rate and an oscillatory shear index were measured for 20 volunteers, aged 23.3 +/- 1.9 years, in the three arteries, using phase contrast imaging with 0.0625 mm2 resolution and three-dimensional paraboloid fitting. RESULTS: The superficial femoral artery had the lowest mean (130.3 +/- 13.1 second(-1)), maximum (735.8 +/- 32.4 second(-1)), and minimum (-224.5 +/- 17.0 second(-1)) wall shear rate, as well as the highest oscillatory shear index (0.21 +/- 0.02). All values were significantly different (P < 0.05) from both the brachial artery and the common carotid artery values. The highest mean (333.3 +/- 13.6 second(-1)) and minimum (117.9 +/- 24.5 second(-1)) wall shear rates and the lowest oscillatory shear index (0 +/- 0) were found in the common carotid artery. CONCLUSION: It is possible to measure wall shear rate in vivo in different arteries using MRI with very high resolution. The findings exhibit the in vivo environment of wall shear rates and suggest a nonuniform distribution of wall shear rates throughout the arterial system.

Adult↗

Three-dimensional phase contrast velocity mapping acquisition improves wall shear stress estimation in vivo.

The purpose of this study was to evaluate and apply high-resolution three-dimensional phase contrast mapping for estimation of wall shear stress in vivo. A silicon pipe of 8 mm diameter with a 8.3 ml/s steady flow and the entrance of the carotid bifurcation in 10 young healthy volunteers aged 23.6 +/- 3.1 years was studied. Very high resolution three-dimensional and two-dimensional phase contrast mapping sequences with spatial resolutions of 0.31 x 0.31 x 1.5 mm(3) and 0.31 x 0.31 x 3 mm(3), respectively, were compared in vivo and in vitro. Wall shear stress was calculated using multi-sectored, three-dimensional paraboloid fitting. In comparison to the two-dimensional measurements, the three-dimensional method with only half the slice thickness gave higher signal-to-noise ratio and velocity-to-noise ratios both in vivo and in vitro. Wall shear stress derived from the three-dimensional velocity measurements did not differ from the two-dimensional velocity measurements either in vitro or in vivo. Mean wall shear stress was lowest and oscillatory shear index was highest at the outer wall, towards the carotid bifurcation. Three-dimensional velocity mapping increases resolution and image quality and allows estimation of wall shear stress patterns circumferentially and longitudinally in human arteries.

Adult↗