PubMed Health⌕ Search

Biomedical subjects

Shenghua Xu

Publications and source records attributed to Shenghua Xu.

4 recordsLinked to original sources

Optical factors determined by the T-matrix method in turbidity measurement of absolute coagulation rate constants.

Turbidity measurement for the absolute coagulation rate constants of suspensions has been extensively adopted because of its simplicity and easy implementation. A key factor in deriving the rate constant from experimental data is how to theoretically evaluate the so-called optical factor involved in calculating the extinction cross section of doublets formed during aggregation. In a previous paper, we have shown that compared with other theoretical approaches, the T-matrix method provides a robust solution to this problem and is effective in extending the applicability range of the turbidity methodology, as well as increasing measurement accuracy. This paper will provide a more comprehensive discussion of the physical insight for using the T-matrix method in turbidity measurement and associated technical details. In particular, the importance of ensuring the correct value for the refractive indices for colloidal particles and the surrounding medium used in the calculation is addressed, because the indices generally vary with the wavelength of the incident light. The comparison of calculated results with experiments shows that the T-matrix method can correctly calculate optical factors even for large particles, whereas other existing theories cannot. In addition, the data of the optical factor calculated by the T-matrix method for a range of particle radii and incident light wavelengths are listed.

Journal Article↗

Study on improving the turbidity measurement of the absolute coagulation rate constant.

The existing theories dealing with the evaluation of the absolute coagulation rate constant by turbidity measurement were experimentally tested for different particle-sized (radius = a) suspensions at incident wavelengths (lambda) ranging from near-infrared to ultraviolet light. When the size parameter alpha = 2pi a/lambda > 3, the rate constant data from previous theories for fixed-sized particles show significant inconsistencies at different light wavelengths. We attribute this problem to the imperfection of these theories in describing the light scattering from doublets through their evaluation of the extinction cross section. The evaluations of the rate constants by all previous theories become untenable as the size parameter increases and therefore hampers the applicable range of the turbidity measurement. By using the T-matrix method, we present a robust solution for evaluating the extinction cross section of doublets formed in the aggregation. Our experiments show that this new approach is effective in extending the applicability range of the turbidity methodology and increasing measurement accuracy.

Models, Chemical↗

Improved procedure on the microscopic approach to determine colloidal stability.

We present an improved procedure on the approach to determine the stability of polystyrene spheres at microscopic particle levels by means of artificially induced particle collisions with the aid of optical tweezers [J. Chem. Phys. 119, 2399 (2003)]. The basic consideration on this new development is that the major contribution to the sticking probability for a particle pair caught into the optical trap for a short period is from its single collision; therefore, if the trapping duration for the pair is taken to be short, the accumulated sticking probability will be a good approximation for the single collision. The experimental procedure associated with this approximation does not resort to exactly controlling the short trapping duration or request the trapping duration correction as previously reported, and therefore it is more practical and applicable for a broader range of the stability ratio. The experimental results under different electrolyte concentrations by the new procedure are consistent with those from the turbidity measurements.

Journal Article↗

Axial optical trapping forces on two particles trapped simultaneously by optical tweezers.

Optical tweezers, which utilize radiation pressure to control and manipulate microscopic particles, are used for a large number of applications in biology and colloid science. In most applications a single optical tweezers is used to control one single particle. However, two or more particles can be trapped simultaneously. Although this characteristic has been used in applications, no theoretical analysis of the trapping force or the status of the trapped particles is available to our knowledge. We present our calculation, using a ray optics model, of the axial trapping forces on two rigid particles trapped in optical tweezers. The spherical aberration that results from a mismatch of the refractive indices of oil and water is also considered. The results show that the forces exerted by the optical tweezers on the two particles will cause the two particles to touch each other, and the two particles can be stably trapped at a joint equilibrium point. We also discuss the stability of axial trapping. The calculation will be useful in applications of optical tweezers to trap multiple particles.

Journal Article↗