9 recordsLinked to original sources

An augmented reality system for MR image-guided needle biopsy: initial results in a swine model.

PURPOSE: To evaluate an augmented reality (AR) system in combination with a 1.5-T closed-bore magnetic resonance (MR) imager as a navigation tool for needle biopsies. MATERIALS AND METHODS: The experimental protocol had institutional animal care and use committee approval. Seventy biopsies were performed in phantoms by using 20 tube targets, each with a diameter of 6 mm, and 50 virtual targets. The position of the needle tip in AR and MR space was compared in multiple imaging planes, and virtual and real needle tip localization errors were calculated. Ten AR-guided biopsies were performed in three pigs, and the duration of each procedure was determined. After successful puncture, the distance to the target was measured on MR images. The confidence limits for the achieved in-plane hit rate and for lateral deviation were calculated. A repeated measures analysis of variance was used to determine whether the placement error in a particular dimension (x, y, or z) differed from the others. RESULTS: For the 50 virtual targets, a mean error of 1.1 mm +/- 0.5 (standard deviation) was calculated. A repeated measures analysis of variance indicated no statistically significant difference (P > .99) in the errors in any particular orientation. For the real targets, all punctures were inside the 6-mm-diameter tube in the transverse plane. The needle depth was within the target plane in 11 biopsy procedures; the mean distance to the center of the target was 2.55 mm (95% confidence interval: 1.77 mm, 3.34 mm). For nine biopsy procedures, the needle tip was outside the target plane, with a mean distance to the edge of the target plane of 1.5 mm (range, 0.07-3.46 mm). In the animal experiments, the puncture was successful in all 10 cases, with a mean target-needle distance of 9.6 mm +/- 4.85. The average procedure time was 18 minutes per puncture. CONCLUSION: Biopsy procedures performed with a combination of a closed-bore MR system and an AR system are feasible and accurate.

Animals↗

Radiofrequency thermal ablation: correlation of hyperacute MR lesion images with tissue response.

PURPOSE: To investigate the hypothesis that the outer boundary of the hyperintense region observed in hyperacute (several minutes post-ablation) T2 and gadolinium contrast-enhanced (CE) T1-weighted magnetic resonance (MR) lesion images is an accurate predictor of eventual cell death from radiofrequency (RF) thermal ablation. MATERIALS AND METHODS: A low-field, open MR imaging system was used to guide an ablation electrode into a thigh muscle of five rabbits and acquire in vivo T2 and CE T1-weighted MR volumes. Ablation occurred by applying RF current for two minutes with the electrode's temperature maintained at 90 degrees +/- 2 degrees C. After fixation, we sliced and photographed the tissue at 3 mm intervals, using a specially designed apparatus, to obtain a volume of tissue images. Digital images of hematoxylin and eosin (H&E) and Masson trichrome-stained histologic samples were obtained, and distinct regions of tissue damage were labeled using a video microscopy system. After the MR and histology images were aligned using a three-dimensional registration method, we compared tissue damage boundaries identified in histology with boundaries marked in MR images. RESULTS: The lesions have distinct zones of tissue damage histologically: a central zone of necrotic cells surrounded by an outer zone with cells that appeared non-viable and associated with marked interstitial edema. In 14 histology images from five lesions, the inner and outer boundaries of the outer zone were compared with the boundaries of a hyperintense rim that surrounds a central hypointense region in the T2 and CE T1-weighted MR images. For T2 and CE T1-weighted MR images, respectively, the mean absolute distance was 1.04 +/- 0.30 mm (mean +/- SD) and 1.00 +/- 0.34 mm for the inner boundaries, and 0.96 +/- 0.34 mm and 0.94 +/- 0.44 mm for the outer boundaries. The mean absolute distances for T2 and CE T1-weighted MR images were not sufficiently different to achieve statistical significance (P = 0.745, 0.818, for the inner and outer boundary, respectively). CONCLUSION: In hyperacute T2 and CE T1-weighted MR lesion images, observations strongly suggest that the outer boundary of the hyperintense rim corresponds to the region of eventual cell necrosis within a distance comparable to our ability to measure. This is good evidence that during RF ablation procedures, MR lesion images can be used to accurately localize the zone of irreversible tissue damage at the lesion margin.

Animals↗

MRI-guided radiofrequency thermal ablation of normal lung tissue: in vivo study in a rabbit model.

OBJECTIVE: The purpose of this study was to assess the feasibility of MRI to guide and monitor radiofrequency ablation of normal pulmonary tissue in a rabbit model. MATERIALS AND METHODS: Percutaneous puncture and lung radiofrequency ablation were performed in six New Zealand white rabbits under MRI control using a 0.2-T open MRI scanner. Technical feasibility and complication detection were evaluated. The ablation zone appearance and size were assessed using MRI, CT, and gross pathology. Interclass correlation coefficients (ICCs) of the maximum short-axis diameters of the lesions on gross pathology and the corresponding diameters as measured on each MRI pulse sequence and on CT scans were calculated. RESULTS: MRI guidance of percutaneous puncture and radiofrequency ablation of pulmonary tissue is feasible. A pneumothorax was detected and treated using MRI. In the specimen, the mean coagulation necrosis diameter was 9.8 mm. The T1-weighted spoiled gradient-echo fast low-angle shot images showed the highest ICC (0.81) for the thermal lesion diameter. CONCLUSION: Our results indicate that MRI guidance is feasible and useful for radiofrequency ablation of normal pulmonary tissue.

Animals↗

Three-dimensional comparison of interventional MR radiofrequency ablation images with tissue response.

OBJECTIVE: Solid tumors are being treated using radiofrequency (RF) ablation under interventional magnetic resonance imaging (MRI) guidance. We are investigating the ability of MRI to monitor ablation treatments by comparing MR images of thermal lesions to histologically assayed tissue damage. MATERIAL AND METHODS: An open MRI system was used to guide an ablation electrode into five rabbit thigh muscles and acquire post-ablation MR image volumes. We developed a methodology using a 3D computer registration to make spatial correlations. After MR and histology images were registered with an accuracy of 1.32+/-0.39 mm (mean+/-SD), a boundary of necrosis identified in the histology was compared with the outer boundary of the hyperintense region in MR images. RESULTS: For 14 T2-weighted MR images, the absolute distance between boundaries was 0.96+/-0.34 mm (mean+/-SD). Since the small discrepancy between boundaries is comparable to our registration accuracy, the boundaries may match exactly. Similar correlations to histology were obtained with a deformable model segmentation method. CONCLUSIONS: This is good evidence that MR thermal lesion images can be used during RF ablation treatments to accurately localize the zone of necrosis at the lesion margin.

Animals↗

Three-dimensional method for comparing in vivo interventional MR images of thermally ablated tissue with tissue response.

PURPOSE: To investigate the ability of magnetic resonance (MR) to monitor radio-frequency (RF) ablation treatments by comparing MR images of thermal lesions to histologically assayed cellular damage. We developed a new methodology using three-dimensional registration for making spatial correlations. MATERIALS AND METHODS: A low-field, open MRI system was used to guide an ablation probe into rabbit thigh muscle and acquire MR volumes after ablation. After fixation, we sliced and photographed the tissue at 3-mm intervals, using a specially designed apparatus, to obtain a volume of tissue images. Histologic samples were digitized using a video microscopy system. For our three-dimensional registration method, we used the tissue images as the reference, and registered histology and MR images to them using two different computer alignment steps. First, the MR volume was aligned to the volume of tissue images by registering needle fiducials placed near the tissue of interest. Second, we registered the histology images with the tissue images using a two-dimensional warping technique that aligned internal features and the outside boundary of histology and tissue images. RESULTS: The MR and histology images were very well aligned, and registration accuracy, determined from displacement of needle fiducials, was 1.32 +/- 0.39 mm (mean +/- SD), which compared favorably to the MR voxel dimensions (0.70 mm in-plane and 3.0 mm thick). A preliminary comparison of MR and tissue response showed that the region inside the elliptical hyperintense rim in MR closely corresponds to the region of necrosis as established by histology, with a mean absolute distance between MR and histology boundaries of 1.17 mm, slightly smaller than the mean registration error. The MR region slightly overestimated the region of necrosis, with a mean signed distance between boundaries of 0.85 mm. CONCLUSION: Our results suggest that our methodology can be used to achieve three-dimensional registration of histology and in vivo MR images. In MR lesion images, the inner border of the hyperintense region corresponds to the border of irreversible cell damage. This is good evidence that during RF ablation treatments, iMRI lesion images can be used for real-time feedback.

Animals↗

Radio-frequency-induced thermal lesions: subacute magnetic resonance appearance and histological correlation.

PURPOSE: To investigate the relationship between subacute magnetic resonance (MR) images of radio-frequency (RF) ablation lesions and tissue viability as determined from histological tissue samples. MATERIALS AND METHODS: We generated lesions (N = 5) in a rabbit thigh model. Four days later, we obtained in vivo T(2)- and contrast-enhanced (CE) T(1)-weighted images and ex vivo histological samples approximately perpendicular to the electrode path. Using three-dimensional registration and warping, we spatially compared manually segmented boundaries apparent on MR images to boundaries separating distinct histological zones determined from hematoxylin and eosin (H&E) and Masson trichrome (MT) stains, as well as birefringence studies. RESULTS: Lesions have a characteristic MR appearance: an outer hyperintense margin (M2) separating background tissue (M3) from an inner core (M1), in both T(2) and CE T(1) images. Histologically, there are two zones of damage: an outer zone of likely nonviable cells (H2) separating background tissue (H3) from an inner core of coagulated nonviable cells (H1). We measured distances between automatically computed correspondence points along histological and MR boundaries. For T(2) and CE T(1) images, respectively, M1 vs. H1 distances were 0.72 +/- 0.99 mm (mean +/- SD) and 0.10 +/- 0.95 mm, while outer M2 vs. H2 boundary distances were 0.26 +/- 1.16 mm and 0.05 +/- 1.08 mm. The discrepancy between histological and MR boundaries was larger than the variability in segmenting MR images, but probably within registration error. There were no significant differences between T(2) and CE T(1) boundaries. CONCLUSION: Lesion boundaries apparent in both T(2)- and CE T(1)-weighted MR scans, performed several days postablation, similarly predict the histological response. That is, the lesion core (M1) corresponds to nonviable coagulated cells (H1), while the hyperintense margin (M2) corresponds to likely nonviable cells undergoing necrotic changes (H2).

Animals↗

Endoscopically inserted endoluminal receiver coil for high-resolution magnetic resonance imaging of the pancreas: Initial results in an animal model.

BACKGROUND: This study assessed the feasibility of high-resolution magnetic resonance imaging of the pancreas by means of an endoscopically inserted endoluminal magnetic resonance receiver coil. METHOD: A 0.032-inch diameter internal magnetic resonance imaging receiver coil was endoscopically inserted into the pancreatic duct in 4 pigs through the accessory channel of a standard duodenoscope to obtain high-resolution magnetic resonance images by using T1- and T2-weighted sequences. RESULTS: The pig anatomy precluded the usual transoral approach; however, transgastric access allowed endoscopic transpapillary insertion of a receiver coil into the pancreatic duct in all animals without the need for sphincterotomy. The small swine pancreas could then be visualized by magnetic resonance imaging with a 0.3 x 0.3-mm in-plane resolution. CONCLUSION: High-resolution pancreas magnetic resonance imaging is feasible by using an endoscopically inserted endoluminal receiver coil. The smaller stomach and larger pancreatic duct diameter in humans will facilitate clinical application of the imaging procedure.

Animals↗

MR imaging-guided vascular procedures using CO2 as a contrast agent.

OBJECTIVE: The purpose of this study was to test the use of CO(2) as a black blood contrast agent for MR imaging-guided vascular procedures in an animal model. MATERIALS AND METHODS: Repeated intraarterial CO(2) injections were performed through a catheter located in the aorta and the renal arteries of three fully anesthetized pigs. Real-time images were acquired using a steady-state free precession sequence. RESULTS: During the CO(2) injections, the bright blood in the aorta and the main renal artery was totally replaced, and this procedure resulted in an immediate, statistically significant signal loss in the vessel lumen. In more peripheral vessels, CO(2) improved the vessel conspicuity substantially. Confirmation of vessel patency distal to the catheter tip position was possible. CONCLUSION: The use of carbon dioxide in combination with a bright blood MR imaging sequence improves vessel conspicuity and provides immediate information about blood flow distal to the catheter. This technique may be used to facilitate MR imaging-guided intravascular procedures.

Animals↗