Flow injection potentiometric system for the simultaneous determination of inositol phosphates and phosphate: phosphorus nutritional evaluation on seeds and grains.

A simple flow injection potentiometric (FIP) system, which uses a tubular cobalt electrode, has been developed for phosphorus nutritional evaluation of seeds and grains. Inorganic phosphorus, P(i), is determined using a 1 x 10(-2) mol.L(-1) potassium phthalate buffer solution adjusted at pH 4. A sensitivity of 47 mV/decade and an operating range from 10 to 1000 mg.L(-1) (1 x 10(-4)-1 x 10(-2) M) of dihydrogen phosphate are obtained. The inositol phosphates amount, which is referred to the organic phosphorus, P(org), is directly determined from extracts using a 1 x 10(-2) mol.L(-1) Tris-HCl buffer solution adjusted at pH 8. A sensitivity of 127 mV/decade and an operating range of 10-1000 mg.L(-1) (2.5 x 10(-4)-5 x 10(-3) M) of P(org) (expressed as inositol hexakisphosphoric acid monocalcium) are achieved. Some samples of seed and grain are analyzed by an ICP-OES and a spectrophotometric method to compare results to the developed flow system; no significant differences at the 95% confidence level are observed using a paired t test. Other samples such as animal nursing feed, soybean meal, and corn are also analyzed with the proposed FIP system, showing a good correlation to the ICP-OES values.

Edible Grain↗

In-soil potassium sensor system.

A potentiometric sensor system based on potassium ion-selective electrodes was developed for agricultural purposes. Sensors were built using PVC ion-selective membranes over an inner solid contact prepared with graphite-epoxy composites. A copper plate was used as a reference electrode. A two-stage electronic circuit composed of current and voltage amplifiers was designed to interface the sensors to a distributed data acquisition system. Three ion-selective sensors and three off-the-shelf temperature sensors and their associated circuits were mounted in a PVC tube to set up a soil probe. The electronic controls were placed in an airtight box fixed at the upper part of the probe. The system was evaluated in the field, where the sensors presented sensibility within the range of 69-71 mV dec(-)(1). Extracts of soil samples were analyzed by a current flame photometry approach, and the results, compared with the probe measurements, showed a linear relationship (r (2) = 0.992 and 0.995, respectively, to 5 and 20 cm depths), which implies viability and instrumentation reliability for agricultural applications.

Ion-Selective Electrodes↗