PubMed Health⌕ Search

Biomedical subjects

Shigeo Wada

Publications and source records attributed to Shigeo Wada.

12 recordsLinked to original sources

Particle method for computer simulation of red blood cell motion in blood flow.

A particle method for the computer simulation of blood flow was proposed to analyze the motion of a deformable red blood cell (RBC) in flowing blood plasma. The RBC and plasma were discretized by particles that have the characteristics of an elastic membrane and a viscous fluid, respectively. The membrane particles were connected to their neighboring membrane particles by springs, and the motion of the particles was determined on the basis of the minimum energy principle. The incompressible flow of plasma that was expressed by the motion of the fluid particles was determined by the moving-particle semi-implicit (MPS) method. The RBC motion and plasma flow were weakly coupled. The two-dimensional simulation of blood flow between parallel plates demonstrated the capability of the proposed method to express the blood flow phenomena observed in experiments, such as the downstream motion of the RBC and the deformation of the RBC into a parachute shape.

Blood Circulation↗

Influence of the opening mode of the mitral valve orifice on intraventricular hemodynamics.

We analyzed intraventricular blood flow numerically to study the influence of the mode of mitral valve opening on the flow field in the left ventricle. Four different types of opening mode were examined: gradually axisymmetric, gradually anteroposterior (anatomical), gradually bilateral (anti-anatomical), or instantaneous opening and closing. In these models, the shape of the valve orifice was the same when the mitral valve was opened fully. The results demonstrated that the framework of the velocity profile of transmitral flow was built during the phase of mitral valve opening, which was characterized by the mode of valve opening. After the mitral valve opened completely, the transmitral velocity profile developed while maintaining its topological features. Consequently, each mode of mitral valve opening had its own pattern of intraventricular flow, although mitral valve opening accounted for less than 4% of a cardiac cycle. Particle tracking in the resulting flow field revealed that ventricular ejection was more efficient in the anteroposterior and axisymmetric opening modes. These results addressed the importance of the mode of mitral valve opening in intraventricular flow dynamics.

Blood Flow Velocity↗

Computational flow dynamics in abdominal aortic aneurysm using multislice computed tomography.

Following the introduction of a new multislice computed tomography (MSCT) scanner, it has become possible to produce high-speed CT angiography (CTA), the preferred method for imaging in emergent abdominal vascular conditions. Unlike catheter angiography, multislice CTA not only depicts the vessels but also allows perfusion in adjacent organs to be assessed. To make the most effective diagnostic use of multi-detector row CTA and three-dimensional image post-processing, radiologists must be familiar with the optimal CTA protocols and the typical CT findings in various emergent vascular conditions using computational flow dynamics (CFD). This article describes a technical approach to estimating the blood flow state of human abdominal aortic aneurysms (AAA) in more detail by constructing realistic three-dimensional (3D) vessel models using CFD methods, focusing on pre- and postoperative cases.

Aged↗

Effects of a ventricular untwisting on intraventricular diastolic flow and color M-mode Doppler echocardiograms.

Intraventricular hemodynamics during diastole was numerically analyzed in order to investigate effects of a ventricular untwisting on flow and a pattern of a color M-mode Doppler echocardiogram. Results showed that the ventricular untwisting affected secondary flows by inducing spiral flows in the ventricular cavity especially in the apical region. On the other hand, flows in the long-axis plane were not affected. Timing of formation, size and growing manner of the annular vortex were almost the same regardless of the presence of the ventricular untwisting; the vortex firstly arose in the base region, expanded towards the apex and eventually occupied the upper half of the ventricular cavity. A pattern of a color M-mode Doppler echocardiogram, that is, a spatiotemporal map of velocity along the long axis, was topologically the same as quantitatively confirmed by comparison of propagation velocity (0.43 m/s and 0.42 m/s for the case without and with the ventricular untwisting, respectively). These results suggested that this technique can exclusively capture flow dynamics produced by ventricular expansion with little influence of the ventricular untwisting. Therefore, we concluded that this is advantageous for assessing a left ventricular diastolic function.

Biomechanical Phenomena↗

The application of computer simulation in the genesis and development of intracranial aneurysms.

The genesis and development of intracranial aneurysm have long been of interest but remain not understood. In the present study we simulate the progression of intracranial aneurysms by constructing a computational model of a curved artery. It is hypothesized that high local wall shear stress above a threshold value will lead to degeneration of the arterial wall mechanical properties. And this degenerative effect may continue even after the wall shear stress has become lower than the threshold, which is referred to as the "time remaining effect" in this study. We performed several groups of studies using both assumptions and aneurysm development is observed as result of the interplay between high wall shear stress, wall degeneration and wall deformation. In the growth of aneurysms with "time-remaining effect", the increase of aneurysmal height accelerates in later steps. It is concluded that computer simulation can yield insight into the understanding of the pathophysiology of aneurysmal initiation and growth, and help in clarifying the role of certain hemodynamic parameters.

Biomechanical Phenomena↗

Experimental and numerical studies of adenovirus delivery to outflow tissues of perfused human anterior segments.

PURPOSE: To investigate the efficacy of two different methods of adenoviral transfer of genes to trabecular meshwork (TM) and Schlemm's canal (SC) cells in cultured human anterior segments, using both experimental and numerical analyses. METHODS: Replication-deficient adenoviruses having coding sequence for beta-galactosidase (beta-gal) under the control of the cytomegalovirus promoter were used. Efficiency of gene transfer over time was verified by infecting cultured human TM cells and assaying for beta-gal activity. Next, ostensibly normal paired human eyes were prepared by standard techniques and perfused for 2 to 5 days to measure baseline facilities. Eyes were then infected by one of two methods: standard transcorneal puncture, or injection into a 1 mm diameter silastic segment of supply tubing immediately upstream of the perfusion dish. In both cases, the nominal total dose was 2 x 10(8) viral particles. Five days after viral injection, eyes were harvested and fixed, and wedges from each of four quadrants were examined histologically. Sections were assayed for beta-gal activity and/or stained with toluidine blue. In a parallel study, flow and viral transport within perfused anterior segments were numerically simulated for conditions that approximated those used experimentally. RESULTS: Eyes receiving viral particles by transcorneal injection showed variable levels of beta-gal activity and highly variable TM cellular morphology, ranging from excellent preservation to cellular lysis. Eyes receiving an equivalent viral dose via the supply tubing showed higher transfer efficiency, as judged by almost complete TM cell loss (indicative of viral toxicity) and intense extracellular beta-gal activity from the residual cytoplasm. At lower doses (1/3 to 1/1000 of that used in transcorneal injection) beta-gal activity was still present, while TM cell morphology was good at the lower viral doses. Computer modeling showed that the region beneath the cornea was nearly stagnant, and consequently virus introduced into this region by transcorneal injection was delivered very slowly to the TM. This caused the effective delivered viral dose to be low and sensitively dependent on the volume and shape of the transcorneally injected virus bolus. CONCLUSIONS: Injection of adenovirus into supply tubing led to consistent delivery of reporter gene and approximately 300-fold greater efficiency of gene transfer compared to the transcorneal injection method, and is therefore the preferred method for introducing viral particles into perfused anterior segments. These findings were consistent with computer modeling of flow and mass transport in perfused anterior segments. Although these quantitative results are specific to adenovirus, this general trend should hold for a wide range of perfused compounds.

Adenoviruses, Human↗

Patient Record Information System (PaRIS) for primary health care centers in Indonesia.

This study explores the Patient Record Information System (PaRIS) for primary health care centers in a developing country such as Indonesia. The specific geography of the thousand islands country Indonesia is the reason for transportation difficulties as well as communication problems. This causes a serious adverse effect on the public healthcare service especially in the rural area within the country. Hence, a sustainable system is required that makes use of appropriate Information and Communication Technology (ICT). We developed a clinical information system with modest communication technology combined with a unique database distribution system. The Internet and its free software are the main tools for this system. It is a good opportunity for a developing country such as Indonesia to apply open free software in regard to the healthcare sector. This cost effective and sustainable system can enhance the work of physicians in order to provide better and applicable public health care service.

Ambulatory Care Information Systems↗

Theoretical prediction of low-density lipoproteins concentration at the luminal surface of an artery with a multiple bend.

To elucidate the mechanisms of localization of atherosclerotic lesions in man, the effects of various physical and hemodynamic factors on transport of atherogenic low-density lipoproteins (LDL) from flowing blood to the wall of an artery with a multiple bend were studied theoretically by means of a computer simulation under the conditions of a steady flow. It was found that due to a semipermeable nature of an arterial wall to plasma, flow-dependent concentration polarization of LDL occurred at the luminal surface of the vessel, creating a region of high LDL concentration distal to the apex of the inner wall of each bend where the flow was locally disturbed by the formation of secondary and recirculation flows and where wall shear stresses were low. The highest surface concentration of LDL occurred distal to the acute second bend where atherosclerotic intimal thickening developed. At a Re0=500, the values calculated using estimated diffusivities of LDL in whole blood and plasma were respectively 35.1% and 15.6% higher than that in the bulk flow. The results are consistent with our hypothesis that the localization of atherosclerotic lesions results from the flow-dependent concentration polarization of LDL which creates locally a hypercholesterolemic environment even in normocholesterolemic subjects, thus augmenting the uptake of LDL by vascular endothelial cells existing at such sites.

Arteries↗

Prediction of LDL concentration at the luminal surface of a vascular endothelium.

To find out whether concentration polarization of low-density lipoprotein (LDL) occurs at the surface of a vascular endothelium or not, transport of LDL in flowing blood to an water-permeable endothelium was studied theoretically by means of CFD. Calculations were carried out for an endothelium exposed to a Couette flow by assuming that the surface geometry of the endothelium could be expressed by a cosine function. Two typical cases were considered for the permeability of endothelium to water; one was uniform permeability everywhere in the endothelium, and the other was uneven permeability which was augmented at the intercellular junction. It was found that, in both cases, the surface concentration of LDL increased in going distally from the entrance, taking locally high and low values at the valleys and hills of the endothelium, respectively, and the variation was larger in the case of endothelium with uneven permeability. These results clearly showed that concentration polarization of LDL which might affect the uptake of LDL by the arterial wall certainly occurs at the surface of the endothelium even if the flow is disturbed microscopically by the uneven surface of the endothelium.

Biological Transport↗