PubMed Health⌕ Search

Biomedical subjects

Shigetoshi Shimamoto

Publications and source records attributed to Shigetoshi Shimamoto.

3 recordsLinked to original sources

Prospective study of HDR (192Ir) versus MDR (137Cs) intracavitary brachytherapy for carcinoma of the uterine cervix.

PURPOSE: The aim of this study was to compare the results of high-dose rate (HDR) and medium-dose rate (MDR) intracavitary brachytherapy for carcinoma of the uterine cervix on the basis of a prospective study and to determine the dose rate conversion factor (DRCF) from low-dose rate (LDR) to MDR via HDR, because a DRCF of 0.54 from LDR to HDR has been widely accepted. MATERIALS AND METHODS: Between August 1991 and July 1999, 104 patients were entered into this trial to compare results between HDR (n=54) and MDR (n=50). Three patients were excluded from this study, leaving 54 HDR patients and 47 MDR patients eligible. Method and dose of external beam radiotherapy were the same for both groups. For HDR intracavitary brachytherapy, point A dose was adjusted to 32 Gy/4 fractions for stages I and II, to 30 Gy/4 fractions for stage III, and to 22.5 Gy/3 fractions for stage IV. The corresponding values for MDR were 35.6 Gy/4 fractions, 34 Gy/4 fractions, and 25.5 Gy/3 fractions. The average dose rate at point A was 30 Gy/hour (9.0-65.2) for HDR and 1.7 Gy/hour (1.3-2.2) for MDR. We assumed a DRCF of 0.9 from MDR to HDR. RESULTS: The 3-year cause-specific survival rates for HDR were 85%, 83%, 75%, and 0% for stages I, II, III, and IV, respectively. The corresponding figures for MDR were 100%, 82%, 58%, and 40%. Six of the HDR patients (11%) and 2 of the MDR patients (4%) developed Kottmeier's grade 2 or 3 late complications. A DRCF of 0.6 from LDR to MDR could be derived from a DRCF of 0.9 from MDR to HDR and one of 0.54 from LDR to HDR. CONCLUSIONS: There were no statistically significant differences in cause-specific survival and incidence of late complications between HDR and MDR. A DRCF of 0.6 from LDR to MDR could be determined. However, because the results of this trial were preliminary, a further study is needed.

Adult↗

[CyberKnife]

The CyberKnife is an image-guided robotic system designed for stereotactic radiosurgery. This system uses a lightweight, x-band linear accelerator, computer-controlled robotic arm, a pair of orthogonal x-ray imagers (TLS: Target Locating System), and a computer workstation. During the treatment, the TLS determines the location of the lesion and communicates these coordinates to the robot. The robot adjusts the position of the beam to the target. The accuracy of this system is 0.7 mm (median) at Osaka University. The CyberKnife system offers new options for radiosurgery/therapy. Stereotactic fractionated radiotherapy can now be performed with the same accuracy as single-fraction stereotactic radiosurgery. The frameless nature of CyberKnife allows tumors in the chest and abdomen to be treated as well. The real time tracking system option enables one to treat tumors that move with respiration, such as lesions in lung. Tumors in the lower spine, pancreas, and lung have already been treated in the USA. A description of the components, accuracy, and future of the CyberKnife will be presented.

Journal Article↗

CyberKnife stereotactic irradiation for metastatic brain tumors.

BACKGROUND: The CyberKnife provides a new technique for performing frameless stereotactic irradiation. So far, few reports have been published on clinical outcomes obtained with the CyberKnife. This report summarizes our clinical experience with CyberKnife irradiation for metastatic brain tumors. MATERIALS AND METHODS: Seventy-seven lesions (48 patients) were evaluated and analyzed, and 66 lesions in 41 patients were treated with stereotactic radiosurgery (SRS). The prescribed dose was 9 to 30 Gy. RESULTS: Freedom from progression of the tumors was more likely with a prescribed dose of at least 24 Gy than with one of less than 20 Gy (p=0.0244; log-rank test). The CR (complete response) rate was significantly higher when D99 was at least 24 Gy (p=0.0045). There were no severe side effects. CONCLUSION: Stereotactic irradiation with the CyberKnife for metastatic brain tumors is effective and safe. D99 should be at least 24 Gy for CyberKnife SRS treatment.

Brain Neoplasms↗