PubMed Health⌕ Search

Biomedical subjects

Shin Mizukami

Publications and source records attributed to Shin Mizukami.

4 recordsLinked to original sources

Varying DNA base-pair size in subangstrom increments: evidence for a loose, not large, active site in low-fidelity Dpo4 polymerase.

We describe the first systematic test of steric effects in the active site of a Y-family DNA polymerase, Dpo4. It has been hypothesized that low-fidelity repair polymerases in this family more readily accept damaged or mismatched base pairs because of a sterically more open active site, which might place lower geometric constraints on the incipient pair. We have tested the origin of low fidelity by use of five nonpolar thymidine analogues that vary in size by a total of 1.0 A over the series. The efficiency and fidelity of base-pair synthesis was measured by steady-state kinetics for single-nucleotide insertions. Analogues were examined both as incoming deoxynucleoside triphosphate (dNTP) derivatives and as template bases. The results showed that Dpo4 preferred to pair the thymidine shape mimics with adenine and, surprisingly, the preferred size was at the center of the range, the same optimum size as recently found for the high-fidelity Klenow fragment (Kf) of Escherichia coli DNA Pol I. However, the size preference with Dpo4 was quite small, varying by a factor of only 30-35 from most to least efficient thymidine analogue. This is in marked contrast to Kf, which showed a rigid size preference, varying by 1100-fold from best to worst. The fidelity for the non-hydrogen-bonding analogues in pairing with A over T, C, or G was much lower in Dpo4 than in the previous high-fidelity enzyme. The data establish that, unlike Kf, Dpo4 has very low steric selectivity and that steric effects alone cannot explain the fidelity (albeit low) that Dpo4 has for a correct base pair; the findings suggest that hydrogen bonds may be important in determining the fidelity of this enzyme. The results suggest that the low steric selectivity of this enzyme is the result of a conformationally flexible or loose active site that adapts with small energetic cost to different base-pair sizes (as measured by the glycosidic C1'-C1' distance), rather than a spatially large active site.

Base Pairing↗

Adjustment of twist angles in pseudo-helical lanthanide complexes by the size of metal ions.

Control of self-assembled nanostructures is a promising technique for nanotechnology. We have examined as to whether nanostructures could be controlled by the size of the central metal ion. Lanthanides are a natural choice for such a study as the size of their trivalent ions changes with atomic number gradually. For this investigation, a series of rare earth complexes ([LaL(1)], [CeL(1)], [SmL(1)], [TbL(1)], [YL(1)], and [LuL(1)]) with a tripodal heptadentate ligand L(1) were synthesized, and their X-ray crystallographic analysis was performed. Although the structures of the ligand (H(3)L(1)) and of the metal complex ([ML(1)]) were quite different, all complexes were almost isostructural pseudohelices. The result of the crystallographic studies demonstrated that the twist angles of helices in the complexes depend on the ionic size of the central metal. A detailed analysis helped determine which portion of the helical strand contributed to the total helicity, and the major cause for the difference in helicity among the lanthanides is discussed. Moreover, this result is the first example showing that La(I) (II) and Lu(I) (II) complexes with the same tripodal heptadentate ligand are isostractural.

Journal Article↗

A fluorescent anion sensor that works in neutral aqueous solution for bioanalytical application.

Anion recognition and anion sensing are of interest because anions play many important roles in living organisms. Most currently known anion sensors work only in organic solution, but sensors for biological applications are required to function in neutral aqueous solution. We have designed and synthesized a novel fluorescent sensor for anions. The sensor molecule 1-Cd(II) contains 7-amino-4-trifluoromethylcoumarin as a fluorescent reporter and Cd(II)-cyclen (1,4,7,10-tetraazacyclododecane) as an anion host. In neutral aqueous solution, Cd(II) of 1-Cd(II) is coordinated by the four nitrogen atoms of cyclen and the aromatic amino group of coumarin. When various anions are added to 100 mM HEPES buffer solution (pH 7.4) containing 1-Cd(II), the aromatic amino group of coumarin is displaced from Cd(II), causing a change of the excitation spectrum. While pyrophosphate and citrate were detected with high sensitivity, fluoride and perchlorate produced no response. Among organic anions, ATP and ADP gave strong signals, while cAMP showed little signal. By utilizing the different affinities of the sensor for AMP and cAMP, the activity of phosphodiesterase, which cleaves cyclic nucleotide, was monitored in real-time. The sensor should have many biochemical and analytical applications and the sensing principle should be widely applicable to the sensing of other molecules.

3',5'-Cyclic-AMP Phosphodiesterases↗