Three-dimensional velocity mapping of lung motion using vessel bifurcation pattern matching.

We present a new quantification technique for three-dimensional (3D) lung motion by means of tracking the anatomical features inside the lung using a set of sequential 3D-CT images (a 4D-CT image). The method is based on the conservation of topology, such as connections and junctions of vessels, during the motion. Lung CT images are used to do lung volume modeling, lung vessel extracting and thinning, and coordinates of vessel bifurcations are derived as feature points. Such feature points are tracked in a series of 3D-CT images, i.e., the points are individually tracked between two successive 3D-CT images, in which the lung is deformed. Consequently, 3D displacement vectors are obtained. The feature point tracking is carried out using point pattern matching with a probabilistic relaxation method. We examined this technique using a lung 3D-CT image and artificially deformed one, and separately scanned CT images for a rigid bifurcation phantom. The studies estimated that the error of the vectors is within approximately 1 voxel, i.e., 1 mm or less. Therefore, the accuracy is expected to be high enough for radiation therapy. This technique enables us to quantify realistic 3D organ motion without any fiducial markers. It can be applied to the quantification of tumor (target volume) deformation by gridding interpolation into all voxels. We expect it to be useful for dose estimation in mobile organs and for 4D treatment planning in radiation therapy.

Algorithms↗

Commissioning of a conformal irradiation system for heavy-ion radiotherapy using a layer-stacking method.

The commissioning of conformal radiotherapy system using heavy-ion beams at the Heavy Ion Medical Accelerator in Chiba (HIMAC) is described in detail. The system at HIMAC was upgraded for a clinical trial using a new technique: large spot uniform scanning with conformal layer stacking. The system was developed to localize the irradiation dose to the target volume more effectively than with the old system. With the present passive irradiation method using a ridge filter, a scatterer, a pair of wobbler magnets, and a multileaf collimator, the width of the spread-out Bragg peak (SOBP) in the radiation field could not be changed. With dynamic control of the beam-modifying devices during irradiation, a more conformal radiotherapy could be achieved. In order to safely perform treatments with this conformal therapy, the moving devices should be watched during irradiation and the synchronousness among the devices should be verified. This system, which has to be safe for patient irradiations, was constructed and tested for safety and for the quality of the dose localization realized. Through these commissioning tests, we were successfully able to prepare the conformal technique using layer stacking for patients. Subsequent to commissioning the technique has been applied to patients in clinical trials.

Calibration↗

Estimating uncertainties of the geometrical range of particle radiotherapy during respiration.

PURPOSE: To propose a method for estimating uncertainties of the range calculation in particle radiotherapy associated with patient respiration. MATERIALS AND METHODS: A set of sequential CT images at every 0.2 s was reconstructed from continuous X-ray projection data accumulated by dynamic helical scanning. At the same time that CT data was acquired, the respiratory signal of the patient and the X-ray on/off signal on CT scanner were recorded. Each CT image was timed according to the phase of respiration waveform. Conversion of the CT number to the water equivalent path length (WEL) was performed with our treatment planning system that included a conversion table. As an illustration, the CT images of a patient with liver cancer at the right upper lobe were analyzed. The geometric size of the liver and WELs from body surface to isocenter were measured in each CT image. RESULTS: Variations of WEL from body surface to isocenter at the anterior-posterior and posterior-anterior direction were 6.2 mm and 18.9 mm, respectively. Liver size changed by 35.2 mm. However, these variations were shown to be considerably reduced by gated irradiation. CONCLUSIONS: A method using sequential CT images with respiration waveform was proposed. It appeared to be useful in evaluating the uncertainties of the range calculation associated with patient breathing.

Artifacts↗

A CT calibration method based on the polybinary tissue model for radiotherapy treatment planning.

A method to establish the relationship between CT number and effective density for therapeutic radiations is proposed. We approximated body tissues to mixtures of muscle, air, fat and bone. Consequently, the relationship can be calibrated only with a CT scan of their substitutes, for which we chose water, air, ethanol and potassium phosphate solution, respectively. With simple and specific corrections for non-equivalencies of the substitutes, a calibration accuracy of 1% will be achieved. We tested the calibration method with some biological materials to verify that the proposed method would offer the accuracy, simplicity and specificity required for a standard in radiotherapy treatment planning, in particular with heavy charged particles.

Adipose Tissue↗