Comparison of brachial-ankle pulse wave velocity in Japanese and Russians.

Pulse wave velocity (PWV) is a well-known indicator of arterial stiffness and a marker of the presence of vascular lesions. Cardiovascular mortality in Russia has become the highest in the world. The Japanese are enjoying long lives, and the mortality caused by cardiovascular diseases has thus far remained at lower levels than that in Russia. In this study, we focused on brachial-ankle pulse wave velocity (baPWV) obtained from normal human subjects in Russia as well as in Japan, and compared their respective cardiovascular risks. We evaluated baPWV in 337 Japanese and 138 Russian healthy subjects. The baPWV was recorded using a PWV diagnosis device. BaPWV was measured between 2 locations of the arterial tree. The baPWV in the Russian group was significantly higher than that obtained in the Japanese of two groups categorized by age (40-59 years and 60- years). Further, body mass index (BMI), systolic blood pressure (SBP) and diastolic blood pressure in the Russian group were significantly higher than those obtained in Japanese in three age groups (under 39 years, 40-59 years, and 60- years). Moreover, the baPWV indicated a positive correlation with age, BMI and SBP in both Japanese and Russians, although the increasing trend of the baPWV against age of the Russian group had a larger value than that of the Japanese. Therefore, we suggest that arterial stiffness might be promoted earlier in the Russian group, which might be the main cause of the increased cardiovascular risk in Russia.

Adult↗

Non-blood contacting electro-hydraulic artificial myocardium (EHAM) improves the myocardial tissue perfusion.

Artificial heart (AH) and ventricular assist devices (VAD) are widely used in the clinical setting to assist severe heart failure patients. The concept of direct cardiac compression (DCC) has been in use for several decades and has advantages over intravascular VAD. The process involves compressing the dysfunctional heart from its epicardial surface to avoid the thromboembolic events and decrease the complications and mortality. An Electro-hydraulic Artificial Myocardium (EHAM) system was designed and fabricated by Tohoku University. This system may assist cardiac contraction and create pulsatile blood flow. The aim of this study was to clearly define the hemodynamic efficiency of the EHAM system in myocardial tissue perfusion during its application in acute animal experiment. Eight healthy adult goats were used; left lateral thoracotomy was performed and the chest was opened by the resection of the 4th and 5th ribs. Hemodynamic parameters including ECG, blood pressure and cardiac output were continuously monitored. Myocardial tissue perfusion was measured by using Omega flow laser fiber attached to the surface of the heart. During the EHAM compression, and increase in blood pressure and myocardial tissue perfusion was observed in all animals when compared with pre-assisted mode. To conclude, EHAM effectively improves myocardial tissue perfusion and increases the pressure on the initiation of direct cardiac compression immediately. Thus it can be a potentially valuable adjunct in the management of severe heart failure.

Animals↗

Tissue velocity imaging of coronary artery by rotating-type intravascular ultrasound.

Intravascular ultrasound (IVUS) provides not only the dimensions of coronary artery but the information of tissue components. In catheterization laboratory, soft and hard plaques are classified by visual inspection of echo intensity. So-called soft plaque contains lipid core or thrombus and it is believed to be more vulnerable than a hard plaque. However, it is not simple to analyze the echo signals quantitatively. When we look at a reflection signal, the intensity is affected by the distance of the object, the medium between transducer and objects and the fluctuation caused by rotation of IVUS probe. The time of flight is also affected by the sound speed of the medium and Doppler shift caused by tissue motion but usually those can be neglected. Thus, the analysis of RF signal in time domain can be more quantitative than intensity of RF signal. In the present study, a novel imaging technique called "intravascular tissue velocity imaging" was developed for searching a vulnerable plaque. Radio-frequency (RF) signal from a clinically used IVUS apparatus was digitized at 500 MSa/s and stored in a workstation. First, non-uniform rotation was corrected by maximizing the correlation coefficient of circumferential RF signal distribution in two consecutive frames. Then, the correlation and displacement were calculated by analyzing the radial difference of RF signal. Tissue velocity was determined by the displacement and the frame rate. The correlation image of normal and atherosclerotic coronary arteries clearly showed the internal and external borders of arterial wall. Soft plaque with low echo area in the intima showed high velocity while the calcified lesion showed the very low tissue velocity. This technique provides important information on tissue character of coronary artery.

Coronary Artery Disease↗

A Japanese-Russian collaborative study on aging and atherosclerosis.

In Russia, the average life span is decreasing. This phenomenon has not been previously observed in the western hemisphere during periods of relative peace. Although this trend can be attributed to various causes, the available statistics suggest that approximately 55% of the total mortality in Russia at the present time is due to cardiovascular events. Similarly, cardiovascular events are also increasing in Japan and are associated with changes in eating habits. A Japanese-Russian international collaborative study was therefore initiated to investigate this. Data on 102 normal Russian subjects were obtained from a total of 345 patients treated at the Smolensk State Medical Academy outpatients' clinic. The data on the Japanese patients were collected at Tohoku University, Tohoku Rosai Hospital, and Fukuda Denshi Company. Sixty-seven healthy male Japanese volunteers were compared with 44 healthy male Russian patients. In this study, Vasera VS1000 (Fukuda Denshi, Tokyo) was utilized to measure pulse wave velocity (PWV). Linear regression analysis was performed, and the results showed that brachial-ankle PWV (baPWV) was significantly higher in the Russian compared with the Japanese study group. With regard to aging, PWV was found to increase both in the Japanese and Russian subjects, with a significant increase in the latter group during their 40s compared with the Japanese, and with this tendency being carried forward into the 50s. This may be the principal cause for the higher incidence of cardiovascular events reported among Russians. Furthermore, when a straight line regression analysis was performed, the zero axis intercept in both cases showed almost the same value. These results indicated that the PWV may be almost the same in Japanese and Russian populations at the time of birth. In conclusion, at the time of birth, there is no difference in the atherosclerotic status of Japanese and Russian infants. However, over time atherosclerosis becomes more apparent and progresses significantly in the case of Russian subjects. This finding is observed through the analysis of PWV. The present authors intend to continue their study aimed at preventing the further development of atherosclerosis through medical intervention.

Aging↗

Brachio-ankle pulse wave velocity and cardio-ankle vascular index (CAVI).

In order to diagnose arteriosclerosis in any part of the body, pulse wave velocity (PWV) measurement is a useful approach. However, it is considered that the technique of PWV measurement should be simplified. A new method for measuring PWV has therefore been proposed in Japan. The PWV of the brachial artery (ba) and the ankle was measured by applying air pressure with the aid of a volume plethysmograph. Comparisons between the baPWV measurement method and the conventional method are currently being performed. Since satisfactory results have been obtained to date, baPWV has gained popularity throughout Japan. Since this method measures PWV in the arm and foot, it may be said that aortic PWV is not reflected though a large amount of past PWV measurements. BaPWV is influenced by blood pressure. With the baPWV technique, blood pressure compensation is not carried out. Furthermore, the pulse pressure is measured by air pressure; therefore any stimulus that exerts pressure on an artery may influence these results. Due to these reasons, a cardie-ankle vascular index (CAVI) has been proposed in which the pressure wave form indicating the closing of the aortic valve appears in the form of an arterial pressure wave after a fixed delay time. This delay is the time difference between the actual closing of the aortic valve and the measuring point. Prior to the introduction of baPWV, PWV was measured in the carotid artery and foot. As in traditional PWV, baPWV uses the delay time, but between the brachial artery and the ankle artery. However, the carotid artery differs from the brachial artery, and the measured value differs depending on whether the arteriosclerosis is present in the carotid artery or the brachial artery. CAVI is calculated from the ECG, PCG, brachial artery waveform and ankle artery waveform using a special algorithm. This new method represents a breakthrough in the diagnosis of atherosclerosis.

Ankle↗

An artificial myocardium assist system: electrohydraulic ventricular actuation improves myocardial tissue perfusion in goats.

UNLABELLED: Artificial hearts and ventricular assist devices have been widely used clinically to assist patients with severe heart failure. Unfortunately, direct contact between the device and the patient's blood leads to thromboembolic events, and then the need for anticoagulation and infections contribute significantly to complication and mortality. Compressing the dysfunctional heart from its epicardial surface, a nonblood-contacting method of direct mechanical ventricular actuation could provide ventricular support, pulsatile blood flow, and avoid interactions between blood and the surface of the artificial assistance system. An ElectroHydraulic Artificial Myocardial (EHAM) assist system that might assist heart muscle contraction has been developed. The purpose of this study is to determine the efficiency of the EHAM system in perfusing myocardial tissue in an acute animal experiment. METHOD: Healthy adult goats (n = 8) were used in acute animal experiments. A left lateral thoracotomy was done and the chest was opened through the 4th and 5th rib resection. Hemodynamic parameters were continuously monitored including ECG, aortic blood pressure, left ventricular pressure, and pulmonary artery pressure. Myocardial tissue perfusion was measured by using an Omega flow laser fiber attached on the surface of the heart. RESULTS: All the animals achieved significantly increased blood pressure, pulmonary artery flow, and myocardial tissue perfusion during the EHAM compression compared with the nondriving (pre-assisted) mode. CONCLUSIONS: The EHAM system can effectively improve myocardial tissue perfusion and increase blood pressure thus demonstrating a potential for treating failing cardiac performance.

Animals↗

Artificial myocardium with an artificial baroreflex system using nano technology.

Where is the place which should be helped in a patient with congestive heart failure? The answer may be contraction of the heart. At Tohoku University, development research of "the artificial myocardium" has been conducted, using a ball screw type electromagnetic motor. Furthermore, super-miniaturization is being attempted at present. Thus, a system with shape memory alloy is being developed. The cooling speed problem was solved by the application of the Peltier element. A drive at a speed equal to that of a heartbeat was realized by the application of this system. At present, a ventricular assist device is used for patients waiting for a heart transplant in Japan. An air driven type system disturbs a patient's QOL remarkably because it is connected to the drive device. With our concept, energy is provided by using the electromagnetic force from outside of the body by the use of transcutaneous energy transmission system. Magnetic shielding by amorphous fibers was used at Tohoku University to improve the total efficiency. A natural heart can alter the cardiac output corresponding to the demand. Artificial internal organs must participate in the system of the living body, too. Tohoku University has developed a resistance based artificial heart control algorithm, which simulated a baroreflex system to cope with every demand. Nano level sensing equipment is now under development at Tohoku University. At present, development is being conducted aiming at an "intelligent artificial myocardium".

Baroreflex↗