PubMed Health⌕ Search

Biomedical subjects

Shinji Okumura

Publications and source records attributed to Shinji Okumura.

2 recordsLinked to original sources

The role of objective plane angulation on the mandibular image using cross-sectional tomography.

Cross-sectional jaw images in the buccolingual direction obtained by conventional or computerized tomography are used in the image diagnosis of dental implant treatment. This study was performed to clarify the subjective image quality of the mandibular depiction by shifting the angles of the tomographic objective plane. A panoramic machine with a linear tomographic function was used to obtain cross-sectional tomographic images on bilateral first molar regions of 10 dried human mandibles. The angles of tomographic objective planes were shifted horizontally within a range of +/- 20 degrees at intervals of 5 degrees from the tomographic objective plane, which was automatically determined. The image qualities of 4 anatomical structures-alveolar crest, buccal and lingual cortical bone, and mandibular canal-were subjectively scored on a 5-point scale method. As a result, the permitted tomographic objective angles were from -1.7 degrees to 2.5 degrees, a range of 4.2 degrees for all 4 anatomical structures. When this result was compared with a previous geometric result, the permitted range of the angles was quite narrow. The tomographic objective angles should be manually set in accordance with an optimal tomographic plane for individual patients by using the positioning technique in linear tomography.

Alveolar Process↗

Image artifact in dental cone-beam CT.

PURPOSE: The purpose of this study was to investigate the appearance and possible cause of an artifact seen in limited-volume cone-beam CT imaging. METHODS: A water-filled plastic cylinder was used as a phantom of the head. A test object was constructed as a bone-equivalent phantom to be imaged. The test object was variously positioned at the center of the phantom and near its margins. CT images of the test object were acquired using a 3DX Accuitomo system. RESULTS: In slice images with the test object positioned near the margin of the phantom, arch-shaped defects or deformities were observed on the side of the object. There was a negative correlation between the artifact and the CT value of the object. The artifact was larger in images scanned with a higher voltage. CONCLUSION: The probability that this artifact is caused by halation from the image intensifier (II) system is suggested.

Artifacts↗