PubMed Health⌕ Search

Biomedical subjects

Shinji Takemoto

Publications and source records attributed to Shinji Takemoto.

8 recordsLinked to original sources

Adhesion of mouse fibroblasts on hexamethyldisiloxane surfaces with wide range of wettability.

Surface wettability is an important physicochemical property of biomaterials, and it would be more helpful for understanding this property if a wide range of wettability are employed. This study focused on the effect of surface wettability on fibroblast adhesion over a wide range of wettability using a single material without changing surface topography. Plasma polymerization with hexamethyldisiloxane followed by oxygen (O2)-plasma treatment was employed to modify the surfaces. The water contact angle of sample surfaces varied from 106 degrees (hydrophobicity) to almost 0 degrees (super-hydrophilicity). O2 functional groups were introduced on polymer surfaces during O2-plasma treatment. The cell attachment study confirmed that the more hydrophilic the surface, the more fibroblasts adhered in the initial stage that includes super-hydrophilic surfaces. Cells spread much more widely on the hydrophilic surfaces than on the hydrophobic surfaces. There was no significant difference in fibroblast proliferation, but cell spreading was much greater on the hydrophilic surfaces. The fibronectin adsorbed much more on a hydrophilic surface while albumin dominated on a hydrophobic surface in a competing mode. These findings suggest the importance of the surface wettability of biomaterials on initial cell attachment and spreading. The degree of wettability should be taken into account when a new biomaterial is to be employed.

Animals↗

Control of bisphosphonate release using hydroxyapatite granules.

The efficacy of hydroxyapatite (HAp) as a carrier was investigated to establish a method of local administration of bisphosphonates (Bps), which has currently been administered systemically. HAp granules (300-500 microm in size) with different physicochemical features were prepared by altering the sintering temperature. To ascertain the physicochemical properties of the HAp granules, their crystallinity was assessed using X-ray diffraction, the surface morphology was examined under scanning electron microscopy, and the specific surface area and calcium dissolution were evaluated. Different Bps-HAp composites were subsequently prepared and the concentration of Bps released from these composites was measured. The influence of Bps-HAp composites on the rate of osteoclast survival was also evaluated. The results revealed that (1) HAp solubility depends on the sintering temperature; (2) The concentration of released Bps could be controlled by regulating the sintering temperature of HAp as a carrier; and (3) Bps released from Bps-HAp composites reduced the number of osteoclasts. These findings indicated that Bps-HAp composites could be locally administered as a drug delivery system to areas with bone resorption.

Animals↗

Corrosion behavior and surface characterization of titanium in solution containing fluoride and albumin.

The objective of this study was to demonstrate the role of albumin on the corrosion behavior of titanium in a solution containing 2.0 g/l fluoride and either 0.1 or 1.0 g/l albumin. The corrosion behavior and surface characterization of passive films on titanium immersed in such a solution were examined. In addition, the change in pH and the concentration of dissolved titanium in the solution were examined. The results showed that the corrosion of titanium in a solution containing fluoride was distinct, and that adding albumin to the solution containing fluoride suppressed corrosion. Fluorine was detected on the titanium surface immersed in the solution containing fluoride, and dissolution of the titanium was confirmed. The titanium immersed in a solution containing both fluoride and albumin had an albumin film regardless of the albumin concentration. In addition, the amount of dissolved titanium from the titanium immersed in the solution was less than when the solution contained no albumin. It was suggested that the formation of adsorbed albumin films on or in the passive film acted to not only protect the titanium from attack by the fluoride but also suppressed dissolution of the titanium-fluoride compounds.

Albumins↗

Influence of fabrication techniques on retention force of fiber-reinforced composite posts.

The purpose of this study was to compare the retention force of FRC posts which were built up using direct and direct-indirect fabrication techniques with two fiber-reinforced core build-up systems (FibreKor and i-TFC). Posts were cemented in endodontically treated bovine single roots with resin cement using either direct or direct-indirect technique. Following which, the retention force of post-and-cores and fracture sites were examined. It was found that both the retention force and fracture site depended on the fabrication technique and resin cements. Post-and-cores built up with direct-indirect technique had greater retention force than those fabricated using direct technique. Fracture modes most frequently observed were adhesive failure at Resin/Dentin interface, a mixture of adhesive failures at Post/Resin and Resin/Dentin interfaces as well as cohesive failure of resin cements. Based on the results of this study, we concluded that when it comes to post-and-core build-up for endodontically treated tooth, the direct-indirect technique is more effective than the direct technique on the retention force of FRC posts.

Analysis of Variance↗

Selective protein adsorption and blood compatibility of hydroxy-carbonate apatites.

We examined the blood compatibility and protein adsorption on hydroxyapatite and hydroxy-carbonate apatite. Those apatites were synthesized under a 0, 5, or 15% CO(2)-containing N(2) atmosphere by a wet-chemical method with a strong ammonia alkali solution of calcium nitrate and diammonium hydrogen phosphate (5:3 in molar ratio) and subsequent calcination in the range of 105-700 degrees C. From infrared (IR) analysis, the carbonate ions substituted both phosphate ions and hydroxyl ions in the hydroxyapatite lattice; the intensities of IR bands assignable to phosphate ions and hydroxyl ions were reduced on calcinations. The specific surface areas of synthesized apatites decreased with increasing calcination temperature. Blood-clotting properties were evaluated in terms of active partial thromboplastin time, prothrombin time, and the amount of fibrinogen for the plasma in contact with the apatites, indicating that all the apatites barely influenced the blood clotting system. The apatites were in contact with a solution containing both bovine serum albumin (BSA) and beta(2)-microglobulin (beta(2)-MG), and the amounts of those proteins adsorbed on them were examined: the amount of absorbed BSA and beta(2)-MG gradually increased with the calcination temperature below 500 degrees C, while it showed a sudden increase when more than 600 degrees C. Hydroxy-carbonate apatite synthesized under a 15% CO(2)-containing N(2) atmosphere and calcined below 400 degrees C had the greatest selectivity in adsorbing beta(2)-MG. Thus, a higher selectivity for beta(2)-MG adsorption was empirically correlated to carbonate ions incorporated in the hydroxyapatite lattice.

Adsorption↗

Platelet adhesion on titanium oxide gels: effect of surface oxidation.

The correlations between titanium oxide layers on oxidized titanium (Ti) substrates and platelet adhesion were examined. Ti substrates were prepared by three different oxidation methods: the first one was treated with hydrogen peroxide (H2O2) solution, the second one was heated in air at moderate temperatures, and the third one was processed with both H2O2 and heating. The titanium oxide layers formed on the Ti substrates were characterized by wettability, chemical composition, thickness, and crystal phase. The platelet adhesion on these oxide layers was examined and correlated to the characterizations of the surface layers. The number of adhesive platelets seemingly correlated with the contact angle towards distilled water, because the number increased close to 70-80 degrees of the contact angle. The effect of surface oxidation on platelet adhesion was examined in detail and it was found that the composition and thickness of the oxide layer influenced platelet adhesion rather than wettability. Thick titanium oxide layers formed on Ti substrates by heating displayed less platelet adhesion than thin oxide layers on untreated Ti substrates. The largest number of adhesive platelets was found on H2O2-oxidized substrates; the substrates found on amorphous titanium oxide contained the Ti-peroxide radical species. The number of platelets, on the other hand, could hardly be observed on Ti substrates treated with H2O2 and subsequently heated above 300 degrees C. The titanium oxide layer on the substrate was thick and we found it to consist of only a few radical species. That is, the effect of heat treatment accelerates the growth of the oxide layer, and decomposes or decreases the number of radical species. Ti substrates with H2O2 and heat treatment above 300 degrees C held the least number of platelets, and were concluded to be the most inhibitory for platelet adhesion.

Blood Platelets↗

Corrosion behavior and surface characterization of Ti-20Cr alloy in a solution containing fluoride.

The purpose of this study was to investigate the correlation between corrosion resistance and surface composition of an experimental Ti-20 mass% Cr casting alloy in a saline solution containing fluoride. The alloy had a greater resistance to corrosion in a fluoride-containing saline solution than did commercially pure titanium. However, with confirmed dissolution of titanium and chromium, it meant that the fluoride in the saline solution corroded the alloy slightly. X-ray photoelectron spectroscopy analysis revealed that the surface composition of the alloy consisted of titanium and chromium oxides containing hydroxide. The [Ti]/([Ti] + [Cr]) ratio in the surface oxide film decreased when immersed in fluoride-containing saline solution, that is, the surface oxide film became chromium-rich oxide. Therefore, the alloy obtained good corrosion resistance to fluoride due to formation of a chromium-rich oxide film.

Chromium Alloys↗

Bioactivity of metallic biomaterials with anatase layers deposited in acidic titanium tetrafluoride solution.

A simple and versatile treatment was developed to provide various metallic biomaterials such as Ti, NiTi, Ta and SUS 316L stainless steel with in vitro bioactivity or ability to deposit carbonate-incorporated apatite in a simulated body fluid (Kokubo solution). A well-crystallized anatase layer deposited on the metallic biomaterials surfaces after soaking them at 60 degrees C for 24 h in an aqueous solution of titanium tetrafluoride (40 mM) whose pH was adjusted to 1.9 with HCl. The as-coated anatase layers did not deposit apatite. When heated at 300 degrees C they were so bioactive as to deposit apatite within 5 day(s) in the Kokubo solution. The trace amount of fluorine weakly bound in the as-coated anatase layers was suggested to be one of the factors that suppressed the bioactivity.

Journal Article↗