PubMed Health⌕ Search

Biomedical subjects

Shinji Yoshioka

Publications and source records attributed to Shinji Yoshioka.

12 recordsLinked to original sources

Structural assignment of isomeric 2-aminopyridine-derivatized monosialylated biantennary N-linked oligosaccharides using negative-ion multistage tandem mass spectral matching.

To investigate the possibility of structural assignment based on negative-ion tandem multistage (MSn) mass spectral matching, four isomers of 2-aminopyridine (PA)-derivatized monosialylated oligosaccharides (i.e., complex-type N-glycans with an alpha2-3- or alpha2-6-linked sialic acid on alpha1-6 or alpha1-3 antennae) were analyzed using high-performance liquid chromatography/electrospray ion trap time-of-flight mass spectrometry (HPLC/ESI-IT-TOFMS). The negative ion [M-2H]2- is observed predominantly in the MS1 spectra without the loss of a sialic acid. The MS2 spectra derived from it are sufficiently reproducible that MS2 spectral matching based on correlation coefficients can be applied to the assignment of these isomers. The isomers containing a sialic acid on alpha1-6 or alpha1-3 antennae can be distinguished by MS2 spectral matching, but the alpha2-3 and alpha2-6 linkage types of sialic acid cannot be distinguished by their MS2 spectra. However, MS3 spectra derived from fragment ions containing a sialic acid (i.e., C4- and D-type ions) clearly differentiate the alpha2-3 and alpha2-6 linkage types of sialic acid in their MS3 spectral patterns. This difference might be rationalized in terms of a proton transfer from the reducing-end mannose to the negatively charged sialic acid. These two moieties are very close in the structural conformations of the precursor C4-type fragment ions of alpha2-6 linkage type, as predicted by molecular mechanics calculations. Thus, negative-ion MSn (n = 2, 3) spectral matching was demonstrated to be useful for the structural assignment of these four monosialylated PA N-glycan isomers.

Aminopyridines↗

Capillary high-performance liquid chromatography/electrospray ion trap time-of-flight mass spectrometry using a novel nanoflow gradient generator.

A type of high-performance liquid chromatography (HPLC) based on a novel nanoflow gradient generator (Asymptotic-Trace-10-Port-Valve (AT10PV) nanoGR generator) was developed and coupled with an electrospray ion trap time-of-flight mass spectrometer (ESI-IT-TOF MS). Stability of the nanoflow GR HPLC system was tested at flow rates of 20 and 50 nL/min by using a nanoflow meter. Average flow rates in a 2-h run were 51.2 nL/min with RSD 0.7% and 21.0 nL/min with RSD 1.8%. Repeatability of analysis of the nanoHPLC/ESI-IT-TOF MS system was also tested by injecting 1.0 microL of trypsin digested bovine serum albumin (BSA) (100 fmol) into a monolithic silica-ODS column (30 microm i.d., 150 mm in length) through a packed silica-ODS trapping column (particle size 5 microm, 150 microm i.d., 10 mm in length). At a flow rate of 50 nL/min, the result demonstrated a reasonably good repeatability of peak retention times (RSD: 0.32-1.1%) and base-ion peak areas (RSD: 4.4-6.6%).

Chromatography, High Pressure Liquid↗

Simultaneous analysis of 2-aminopyridine-derivatized neutral and sialylated oligosaccharides from human serum in the negative-ion mode by sonic spray ionization ion trap mass spectrometry.

Neutral and acidic (sialylated) 2-aminopyridine-derivatized (PA) oligosaccharides were analyzed by using reversed-phase high-performance liquid chromatography/ion trap mass spectrometry (RP-HPLC/IT MS) with a sonic spray ionization (SSI) source. Under the RP-HPLC separation using a buffer of 1 mM ammonium acetate (pH4.3) at a flow rate of 0.2 mL/min, both PA-oligosaccharides in the negative-ion mode showed a comparable degree of ionization efficiency, differing from that of the positive-ion mode, which exhibits a wide gap between their ionization efficiencies. In addition, the ion intensities of both PA-oligosaccharides were higher in the negative-ion mode than in the positive-ion mode. These results strongly suggest that the negative-ion mode of SSI-MS is suitable for simultaneous analysis of neutral and acidic (sialylated) oligosaccharides in RP-HPLC/MS. In the present study, RP-HPLC/SSI-IT MS in the negative-ion mode was used in the analysis of PA-oligosaccharides from human serum and its usefulness was investigated. As a result, 32 neutral and sialylated PA-oligosaccharides from human serum were identified with differentiating isomeric oligosaccharides and relatively quantified by a single HPLC/MS run. This method is useful for simple and rapid analysis of the overall distribution of neutral and sialylated oligosaccharides in a complex sample such as serum.

Aminopyridines↗

Structural assignment of isomeric 2-aminopyridine-derivatized oligosaccharides using negative-ion MSn spectral matching.

To investigate the possibility of structural assignment based on negative-ion MS2 spectral matching, three isomeric pairs of 2-aminopyridine (PA)-derivatized non-fucosylated, fucosylated, and sialylated oligosaccharides (complex type N-glycans) were analyzed using high-performance liquid chromatography/ion trap mass spectrometry (HPLC/ITMS) with a sonic-spray ionization (SSI) source. In the SSI negative-ion mode the deprotonated molecule [M-2H]2- becomes prominent. Negative-ion MS2 spectra derived from such ions contain many fragment types (B and Y, C and Z, A, and D) and therefore are more informative than the positive-ion MS2 spectra derived from [M+H+Na]2+ ions, which usually consist mainly of B and Y fragment ions. In particular the internal ions (D- and E-type ions) provided useful information about the alpha1-6 branching patterns and the bisecting GlcNAc residue. Spectral matching based on the correlation coefficients between negative-ion MS2 spectra was performed in a manner similar to the positive-ion MS2 spectral matching previously reported. It was demonstrated that negative-ion MS2 spectral matching is as useful and applicable to the structural assignment of relatively large non-fucosylated, fucosylated, and sialylated PA-oligosaccharide isomers as its positive-ion counterpart.

Aminopyridines↗

Arterial air embolism during percutaneous pulmonary marking under computed tomography guidance.

Percutaneous pulmonary marking under computed tomography (CT) guidance is often used to identify the location of small nodules prior to pulmonary wedge resection by video assisted thoracoscopic surgery. Although pneumothorax and pulmonary hemorrhage are known complications that accompany this method, arterial air embolism is an extremely rare and occasionally fatal complication. We report a case of arterial air embolism during percutaneous pulmonary marking under CT guidance. Percutaneous pulmonary marking was performed in the prone position in a 59-year-old male with a right lung nodule. The chest CT performed immediately after this procedure revealed an air-fluid level in the heart. The skin of the patient's back appeared cyanotic and neurological dysfunction was noted in his left thigh, although his vital signs were stable. Four hours later, the air in the heart and aorta disappeared, as observed by a chest CT. The patient underwent pulmonary resection 12 days later.

Embolism, Air↗

Assignment and quantification of 2-aminopyridine derivatized oligosaccharide isomers coeluted on reversed-phase HPLC/MS by MSn spectral library.

2-Aminopyridine (PA)-derivatized oligosaccharides from IgG were analyzed by using reversed-phase HPLC/mass spectrometry (RP-HPLC/MS) and a MS(n) spectral library, in particular, focusing on two pairs of isomers incompletely separated or coeluted in chromatograms. We previously reported that MS(n) spectral matching considering both major fragment ions (m/z) and intensities is useful and applicable to the structural assignment of PA-oligosaccharide isomers. In this study, MS(n) spectral matching based on the MS(n) spectral library was applied to the assignment of these PA-oligosaccharide isomers in IgG. Its usefulness was investigated by comparing it to the conventional two-dimensional mapping method based on retention time indexes. Specifically, we focus on the assignment and quantification of the isomers, which are coeluted in chromatograms. From this, we propose a new method using MS(n) spectral matching and the working curve on which are plotted the relative intensities of selected fragment ions in their MS(2) spectra versus various mixtures of the isomers. This new method demonstrated that the obtained quantities coincide very well with those estimated after separating by a combination of lectin and reversed-phase columns. This means that separation by RP-HPLC/MS is greatly simplified because complete separation of the isomers is no longer required. Application of this new method was tested by using the two other pairs of fucosylated and nonfucosylated PA-oligosaccharides from IgG. The results showed that this method works for them as well.

Aminopyridines↗

Nanoflow gradient generator for capillary high-performance liquid chromatography-nanoelectrospray mass spectrometry.

A novel nanoflow gradient generator using a 10-port switching valve with two injection loops installed, which is referred to here as the "Asymptotic-Trace-10-Port-Valve" (AT10PV) nanoGR generator, has been applied to capillary high-performance liquid chromatography (HPLC)-microelectrospray (microESI) or nanoelectrospray (nanoESI) time-of-flight mass spectrometry (TOF MS). In this study, performance of this capillary HPLC-micro/nanoESI-MS system was tested at a flow rate of 200 nl/min by using three typical peptides (angiotensins I, II, and III: 50 fmol each). The result demonstrated that this system provides reasonably good repeatability of peak retention times (R. S.D. of less than 0.5%). Sequential runs of a series of sample injections were performed in the same manner as conventional analysis at microflow rates.

Chromatography, High Pressure Liquid↗

Nanoflow gradient generator for capillary high-performance liquid chromatography.

A novel method of generating a nanoflow gradient elution for a capillary high-performance liquid chromatography (HPLC) system has been developed. An important feature of this system is that any gradient (GR) profile generated by a conventional microflow GR pump can be asymptotically traced and converted as a corresponding nanoflow GR profile simply by using a 10-port switching valve with two injection loops installed. Consequently, it has been called an "asymptotic trace 10-port valve" (AT10PV) nanoflow GR generator. Performance of the AT10PV nanoflow GR generator was tested in the range of flow rates from 50 to 500 nL/min. The test demonstrated that the AT10PV nanoflow GR generator can asymptotically trace the original gradient profile with good reproducibility. A capillary HPLC system using the AT10PV nanoflow GR generator provides reasonably good repeatability of peak retention times on the chromatogram of the tryptic digest of a BSA sample, RSD of less than 0.3% at a flow rate of 200 nL/min. It also enables sequential running of a series of sample injections in the same manner as conventional analysis at microflow rates.

Acetone↗

Structural assignment of isomeric 2-aminopyridine-derivatized oligosaccharides using MSn spectral matching.

Two isomeric pairs of 2-aminopyridine (PA)-derivatized fucosylated and non-fucosylated oligosaccharides (complex-type N-glycans of IgG) were analyzed using liquid chromatography/ion trap mass spectrometry (LC/ITMS) with a sonic spray ionization source and by varying the collision-induced dissociation voltage. Reproducibility of MS(n) (n = 2) spectra obtained by LC/ITMS was tested considering both fragment ions (m/z) and intensities. A comparison of their MS(n) spectra and evaluation of similarities (or matching), based on correlation coefficients between MS(n) spectra, was investigated as a possibility for structural assignment of the isomers. It is shown that such MS(n) spectral matching is useful and applicable to the structural assignment of relatively large fucosylated and sialylated PA-oligosaccharides released from IgG based on Bn- and Yn-type fragmentations of the corresponding [M+H+Na](2+) ions.

Aminopyridines↗

A new analytical method for gonyautoxins based on postcolumn HPLC.

A new ion-pairing high-performance liquid chromatography (HPLC) method on a C30 column with a volatile mobile phase was developed to separate the gonyautoxin group (GTXs) from contaminants, allowing the utilization of liquid chromatography/mass spectrometry (LC/MS) with higher performance. A mobile phase consisting of 5 mmol/L heptafluorobutyric acid and 2% acetonitrile in 10 mmol/L ammonium acetate was adopted for separation of GTXs because the C30 column strongly retains GTXs under acidic conditions. The newly adopted method could efficiently separate GTXs from contaminants, especially in the toxic short-necked clam, whereas the routine HPLC so far used has poor resolution to separate GTXs from unknown interfering substances. In our method, GTXs were eluted in the order of GTX5, GTX3, GTX4, GTX2 and GTX1 from the C30 column, and were successfully determined by sonic spray ionization mass spectrometry (SSI-MS) with high sensitivity. This method is characterized by the combination of HPLC using a fluorescence detection system for PSP, and SSI-MS for measurement of the mass number.

Chromatography, High Pressure Liquid↗

Pulmonary lesions detected in population-based CT screening for lung cancer: reliable findings of benign lesions.

PURPOSE: To identify the characteristics of benign pulmonary lesions in order to reduce false-positive rates in screening computed tomography (CT) and in order to reduce frequency of follow-up high-resolution CT (HRCT). MATERIALS AND METHODS: We evaluated 238 screening-detected benign lesions and 23 screening-detected lung cancers for 12 characteristics: spiculation, well-defined margin, concave margin, polygonal shape, notch/lobulation, solid component, ground-glass opacity (GGO), air bronchogram, cavity, bubble-like appearance, pleural indentation, and vascular convergence. We also measured the lesion diameters to set a threshold for benign lesions. We tested combinations of these characteristics to differentiate benign lesions from lung cancers. RESULTS: By using certain combinations of the characteristics that showed statistically significant differences between benign lesions and lung cancers, benign lesions could be extracted without contamination by lung cancer in screening CT, when the combination included solid component as a positive finding. In HRCT, more than 80% of the benign lesions could be extracted without contamination by lung cancer when the combination included GGO as a negative finding. CONCLUSION: It seems possible to reduce the frequency of follow-up HRCT to establish a diagnosis of benign lesions using certain combinations of the characteristics of benign nodules.

Aged↗