Effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies.

The purpose of this study was to investigate the effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies using multi-detector row CT (MDCT). Following the standard CT perfusion study protocol, continuous (cine) scans (1 s/rotation x 60 s) consisting of four 5 mm thick contiguous slices were performed using an MDCT scanner with a tube voltage of 80 kVp and a tube current of 200 mA. We generated the simulated images with tube currents of 50 mA, 100 mA and 150 mA by adding the corresponding noise to the raw scan data of the original image acquired above using a noise simulation tool. From the original and simulated images, we generated the functional images of cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) in seven patients with cerebrovascular disease, and compared the correlation coefficients (CCs) between the perfusion parameter values obtained from the original and simulated images. The coefficients of variation (CVs) in the white matter were also compared. The CC values deteriorated with decreasing tube current. There was a significant difference between 50 mA and 100 mA for all perfusion parameters. The CV values increased with decreasing tube current. There were significant differences between 50 mA and 100 mA and between 100 mA and 150 mA for CBF. For CBV and MTT, there was also a significant difference between 150 mA and 200 mA. This study will be useful for understanding the effect of x-ray tube current on the accuracy of cerebral perfusion parameters obtained by CT perfusion studies using MDCT, and for selecting the tube current.

Aged↗

Deconvolution analysis of dynamic contrast-enhanced data based on singular value decomposition optimized by generalized cross validation.

PURPOSE: To present an implementation of generalized cross validation (GCV) for automatically determining the regularization parameter--i.e., the threshold value in deconvolution analysis based on truncated singular value decomposition (TSVD) of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) data--and to investigate the usefulness of this approach in comparison with TSVD with a fixed threshold value (TSVD-F). METHODS: Using computer simulations, we generated a time-dependent concentration of the contrast agent in the volume of interest (VOI) from the arterial input function (AIF) modeled as a gamma-variate function under various cerebral blood flows (CBFs), cerebral blood volumes (CBVs), and signal-to-noise ratios (SNRs) for three different types of residue functions (exponential, triangular, and box-shaped). We also considered the effects of delay and dispersion in AIF. The TSVD with GCV (TSVD-G) and TSVD-F with a fixed threshold value of 0.2 were used to estimate CBF values from the simulated concentration-time curves in the VOI and AIF, and the estimated values were compared with the assumed values. Additionally, the optimal threshold value was determined from the threshold value in TSVD-F giving the mean CBF value closest to the assumed value and was compared with the threshold value determined with TSVD-G. RESULTS: With TSVD-G, the CBF estimation was substantially improved over a wide range of CBFs for all types of residue functions at the cost of more noise than was seen with TSVD-F. The dependency of the threshold value determined with TSVD-G on the CBF, CBV, and SNR was similar to that of the optimal threshold value, with some discrepancy being observed for the box-shaped residue function, although they did not always agree in terms of absolute value. CONCLUSION: Given an improved SNR, TSVD-G is useful for quantification of CBF with deconvolution analysis of DCE-MRI data.

Algorithms↗