PubMed Health⌕ Search

Biomedical subjects

Shoichi Kusano

Publications and source records attributed to Shoichi Kusano.

29 records · Page 2Linked to original sources

Coil compaction after embolization of the superior mesenteric artery pseudoaneurysm.

A 58-year-old man with an abscess of the psoas muscle was returned to our hospital with hematemesis. Two years earlier, he had undergone coil embolization for a superior mesenteric artery (SMA) pseudoaneurysm secondary to pancreatitis. Based on the physical examination, serum amylase level, and abdominal radiographs, a diagnosis of acute exacerbation of pancreatitis and coil compaction of the SMA pseudoaneurysm was made. The patient underwent re-embolization for the coil compaction using interlocking detachable coils. His condition improved gradually, and he was discharged 3 weeks later. To our knowledge, this is the first report of coil compaction of SMA pseudoaneurysm.

Acute Disease↗

Decision-tree sensitivity analysis for cost-effectiveness of whole-body FDG PET in the management of patients with non-small-cell lung carcinoma in Japan.

BACKGROUND: Whole-body 2-fluoro-2-D-[18F]deoxyglucose [FDG] positron emission tomography (WB-PET) may be more cost-effective than chest PET because WB-PET does not require conventional imaging (CI) for extrathoracic staging. METHODS: The cost-effectiveness of WB-PET for the management of Japanese patients with non-small-cell lung carcinoma (NSCLC) was assessed. Decision-tree sensitivity analysis was designed, based on the two competing strategies of WB-PET vs. CI. WB-PET was assumed to have a sensitivity and specificity for detecting metastases, of 90% to 100% and CI of 80% to 90%. The prevalences of M1 disease were 34% and 20%. One thousand patients suspected of having NSCLC were simulated in each strategy. We surveyed the relevant literature for the choice of variables. Expected cost saving (CS) and expected life expectancy (LE) for NSCLC patients were calculated. RESULTS: The WB-PET strategy yielded an expected CS of $951 US to $1,493US per patient and an expected LE of minus 0.0246 years to minus 0.0136 years per patient for the 71.4% NSCLC and 34% M1 disease prevalence at our hospital. PET avoided unnecessary bronchoscopies and thoracotomies for incurable and benign diseases. Overall, the CS for each patient was $833US to $2,010US at NSCLC prevalences ranging from 10% to 90%. The LE of the WB-PET strategy was similar to that of the CI strategy. The CS and LE minimally varied in the two situations of 34% and 20% M1 disease prevalence. CONCLUSIONS: The introduction of a WB-PET strategy in place of CI for managing NSCLC patients is potentially cost-effective in Japan.

Algorithms↗

Measuring portal venous perfusion with contrast-enhanced CT: comparison of direct and indirect methods.

RATIONALE AND OBJECTIVES: Two algorithms can be used to measure portal venous perfusion (PVP) with contrast material-enhanced single-level liver computed tomography. The "direct" and "indirect" algorithms use data from the portal vein and aorta, respectively. This study compared PVP values obtained with direct and with indirect algorithms in a series of patients. MATERIALS AND METHODS: Both techniques were applied in 27 patients with cirrhosis (14 men and 13 women; mean age, 56.1 years +/- 9.4) and 18 control patients (seven men and 11 women; 52.8 years +/- 12.3). A single section through the liver was scanned after intravenous injection of ioversol (40-mL bolus; 320 mg of iodine per milliliter). RESULTS: Both techniques showed reduced PVP in patients with cirrhosis (0.63 for direct and 0.17 for indirect method) compared with control patients (1.06 and 0.26, respectively), but only the direct method agreed with physiologic expectations based on animal and human studies. In separating cirrhotic and control patients, the area under the receiver operating characteristic curve was significantly greater for the direct method (0.91 vs 0.78; P = .03). CONCLUSION: Both direct and indirect methods are feasible and distinguish well between cirrhotic and control patients, but the direct method is more physiologic and is preferable if portal venous data are available.

Algorithms↗

Clinically useful detection criteria for sentinel nodes in patients with breast cancer using a radioisotope technique.

BACKGROUND: The radioisotope technique has been used to identify sentinel nodes in patients with breast cancer. However, quantitative analysis of the radioactivity for detecting the sentinel nodes was not previously examined. In this study, we considered a clinically useful criterion for detecting sentinel nodes by a detailed analysis of 312 sentinel nodes using the radioisotope technique. PATIENTS AND METHODS: Patients with T1-2, N0 breast cancer were eligible for this study. The nodes with the highest radioactivity after injection of technetium-labeled tin colloids were identified as hot nodes. The radioactivities of the hot nodes and the background counts of the axillary basin were examined in order to establish new criteria for detecting the sentinel nodes. RESULTS: Between May 1997 and December 2001, 312 hot nodes were detected in 183 of 186 patients (98.4%). Since the false-negative rate for metastasis in hot nodes was only 2.1% (1/48), they could serve as sentinel nodes to predict the nodal status. However, there was a wide distribution of the hot nodes and the background in terms of absolute counts and a criterion for the sentinel nodes could not be established in terms of the absolute counts. When we adopted the criterion of sentinel nodes with a >/=100 count ratio in relation to the background, only 169 hot nodes (54.3%) met our definition. When the criterion of a >or=10 count ratio was adopted, all hot nodes met our definition and all other nodes remained non-sentinel nodes. CONCLUSION: The criterion for defining sentinel nodes in our method is a node with a >or=10 count ratio with respect to the background. It is recommended that an analysis based on such objective data should be investigated in order to provide surgeons with more accurate and clinically useful criteria for detecting sentinel nodes.

Adult↗

Transfemoral superior ophthalmic vein approach via the facial vein for the treatment of carotid-cavernous fistulas--two case reports.

Two elderly female patients with carotid-cavernous fistulas (CCFs) were treated by transvenous embolization through a transfemoral superior ophthalmic vein approach via the facial vein. Complete occlusion of CCFs was not achieved with this technique exclusively, but the technique was effective in these cases. This technique provides an alternative to other transvenous approaches for the treatment of CCFs.

Aged↗

Intracranial meningeal involvement in Churg-Strauss syndrome.

We describe the case of a 54-year-old woman with a clinical diagnosis of Churg-Strauss syndrome (CSS). The patient had a fever of unknown origin, severe headache, progressing left ophthalmoplegia, and visual acuity disturbance. MR imaging revealed diffuse and thick hypointense lesions on T2-weighted images in the frontal meninges and anterior falx cerebri with diffuse enhancement. Similar lesions were also detected in the left superior ophthalmic fissure to the cavernous sinus. Nodular lesions in the fourth ventricle, which might have been the cause of hydrocephalus, were hypointense on T2-weighted images. These MR imaging findings suggested remote granulomatous involvement in the meninges and choroid plexus associated with CSS. To our knowledge, remote meningeal involvement in association with CSS has not been previously reported.

Brain↗

Carcinoid tumor of the ampulla of Vater. Magnetic resonance imaging findings.

Carcinoid tumors arising from the ampulla of Vater are rare, and their magnetic resonance (MR) imaging findings have not been reported in the literature to date. We report a case of carcinoid tumor of the ampulla of Vater and discuss the characteristic MR imaging findings. The tumor was isointense relative to the muscle on both the T1- and T2-weighted images with heterogeneous enhancement after gadolinium administration. Both the common bile and the pancreatic ducts were dilated on the MR cholangiopancreatography.

Aged↗

Magnetic resonance imaging findings of Machado-Joseph disease: histopathologic correlation.

PURPOSE: To determine the characteristic magnetic resonance imaging (MRI) findings of early- and late-stage Machado-Joseph disease (MJD) and to examine correlation with pathologic specimens. PATIENTS AND METHODS: Four patients genetically diagnosed with MJD and a familial case of MJD were all examined using MRI. Machado-Joseph disease was pathologically confirmed in one of the four genetically diagnosed patients, and the findings were compared with the MRI results. RESULTS: In all three patients who had MJD for less than 8 years, MRI confirmed mild cerebellar atrophy, particularly in the vermis, and atrophic changes in the superior cerebellar peduncle. Mild pontine atrophy was observed in these three patients. Atrophic changes in the pontine tegmentum were more prominent than those of the pontine base in these patients. Two of the three patients showed mild frontal atrophy. Of the five total patients, two had the disease for over 10 years and showed progressive atrophy of the brainstem and mild frontal atrophy. These two patients also showed pallidal atrophy. One autopsied case in which the disease duration was 17 years showed a typical pathologic picture of MJD. Macroscopic findings for this patient showed marked atrophy of the pons, mild cerebellar atrophy (particularly in the vermis), marked atrophy of the superior cerebellar peduncle, severe involvement of motor nuclei, and atrophy and discoloration of the pallidum and subthalamic nuclei. CONCLUSION: In the early stages of MJD, mild pontine atrophy, particularly in the tegmentum, and mild cerebellar atrophy are typical MRI findings. Atrophic changes in the brainstem may be progressive. Pallidal atrophy may be observed in patients with long disease duration. These findings correlated with the pathologic findings.

Adult↗

Primary peritoneal clear cell carcinoma.

The computed tomography (CT) and magnetic resonance imaging findings of primary peritoneal clear cell carcinoma in a 53-year-old woman are reported. A CT scan showed a complex cystic mass with solid components that involved the right upper quadrant and displaced the liver and the right kidney. Magnetic resonance imaging revealed a multicystic mass with hemorrhage and heterogeneous solid protrusions. The diagnosis of primary peritoneal clear cell carcinoma was made by histopathologic study of the surgical specimen.

Adenocarcinoma, Clear Cell↗

Invasive ductal carcinoma of the breast with a large central acellular zone associated with matrix-producing carcinoma.

Matrix-producing carcinoma is a variant of metaplastic carcinoma of the breast that consists of overt carcinoma with direct transition to a cartilagenous and osseous stromal matrix. A clinicopathological association between MPC and high-grade invasive ductal carcinoma with a large central acellular zone has been recently discussed. However, few reports have ever shown the radiological, pathological and immunohistochemical correlation of this unique tumor. We present a case of 27-year-old woman with matrix-producing carcinoma with a large central acellular zone, which was characterized by a large homogeneous hypodense center with well-marginated, ring-like enhancement on contrast enhanced computerized tomography.

Adult↗

Soft copy using image processing in place of hard copy for detection of subtle pulmonary lesions: is it actually cost-effective?

PURPOSE: To comparatively assess the interpretation performance of hard-copy versus soft-copy presentations for detecting subtle pulmonary lesions and to estimate soft-copy cost-effectiveness. METHODS: Computed radiography was used to obtain images with a 1,600x 1,200 matrix having 8 bits of gray-scale definition. The two separate image formats (hard and soft copy), which consisted of 60 chest radiograph combinations, were shown to five board-certified radiologists. The costs of hard copies, chemicals, waste disposal, and labor were calculated. RESULTS: The mean accuracies and Az values were 0.63 (hard) vs. 0.64 (soft) and 0.657 (hard) vs. 0.729 (soft), respectively. Reading one set of hard copies took on average 8.0 sec less than reading soft copies (30.3 vs. 38.3 sec). Estimated savings resulting from replacement of hard copy with soft were US$128,004 per year or US$6.20 per patient at our hospital. CONCLUSION: Conversion from hard copy to soft copy, using image processing, is feasible and cost-effective.

Adult↗