Requirements for laser-induced desorption/ionization on submicrometer structures.

Laser-induced and matrix-free desorption/ionization on various submicrometer structures was investigated. First, to examine the effect of surface roughness on ionization, a silicon wafer or stainless steel was scratched with sandpaper. The fluences of a 337-nm nitrogen laser, required for ionization of synthetic polymers and reserpine, were markedly reduced on the scratched stainless steel or silicon as compared to the corresponding untreated surface. Next, arrays of submicrometer grooves, which had been lithographically fabricated on a silicon wafer, yielded protonated angiotensin, and the morphologic orientation demonstrated the positive relation between the laser and groove directions for promoting ionization. The fabricated structure also suggested the submicrometer, but not smaller, or nanometer, structures to be a key factor in direct desorption/ionization on rough surfaces. Finally, submicrometer porous structures of alumina or polyethylene yielded intense molecular ion signals of angiotensin and insulin, in response to direct UV irradiation, when the surface was coated with Au or Pt. The coating provided the additional advantage of prolonged activity for a porous alumina chip, exceeding a month even when the chip was left in the open air. These results indicate that laser-induced desorption/ionization of organic compounds can be implemented on submicrometer structures with an Au- or Pt-coated surface irrespective of the basal materials.

Adsorption↗

Measurement of serum salicylate levels by solid-phase extraction and desorption/ionization on silicon mass spectrometry.

The applicability of the matrix-free laser desorption/ionization on silicon mass spectrometry (DIOS-MS) to measuring serum drug levels was examined by analyzing serum salicylic acid. The optimized and simple solid-phase extraction (SPE) allowed good recovery, 88.9 +/- 5.8%, for 1.4 mM (200 mg/L) of salicylic acid in serum. The negative ion MS allowed measurements of deprotonated molecules without interference from other signals. Using a deuterium-labeled internal standard, good linearity was obtained in the 0.14 to 4.2 mM (20-600 mg/L) range, which was sufficient for monitoring the therapeutic anti-inflammatory dose. SPE followed by DIOS-MS is anticipated to be a method of measuring drug levels in blood and may allow high throughput analysis.

Humans↗

Oxidation of ferrocene derivatives in desorption/lonization on porous silicon.

In matrix-assisted laser desorption/ionization (MALDI), the true molecular structures of some analytes are not represented by the observed ions due to a redox reaction. In earlier reports, electron transfer from analyte to chemical matrix has been proposed for the oxidation of ferrocene derivatives in MALDI. To address such a redox phenomenon in laser desorption/ionization processes, two ferrocene derivatives, FcCH2CH2Fc and FcCH2NMe2 [Fc:(CsHs)Fe(CsH4)], were analyzed by a matrix-free method, desorption/ionization on porous silicon (DIOS). The oxidized species, Fc+CH2NMe2 and FcCH2CH2Fc+, were detected in the DIOS mass spectra. The results suggested that electron transfer from the analytes to the sample target occurs during the ionization process.

Journal Article↗

Mass spectrometric analysis of low molecular mass polyesters by laser desorption/ionization on porous silicon.

A low molecular mass polyester was analyzed by desorption/ionization on porous silicon (DIOS) mass spectrometry. The results were compared with those of matrix-assisted laser desorption ionization (MALDI) mass spectrometry using matrixes of alpha-cyano-4-hydroxycinnamic acid (CHCA) and 10,15,20-tetrakis(pentafluorophenyl)porphyrin (F20TPP). The CHCA matrix was not suitable for characterization of low molecular mass components of the polyester because the matrix-related ions interfered with the component ions. On the other hand, the F20TPP matrix showed no interference because no matrix-related ions appeared below m/z 822. However, the solvent selection for determining optimal conditions of sample preparation was limited, because F20TPP does not dissolve readily in any of the available organic solvents. In the DIOS spectra, the polymer ions were observed at high sensitivity without a contaminating ion. No matrix is needed for DIOS spectra of low molecular mass polyesters, facilitating sample preparation and selectivity of a precursor ion in post-source decay measurements.

Molecular Weight↗

Reduction of organic dyes in matrix-assisted laser desorption/ionization and desorption/ionization on porous silicon.

Reduction of analytes in matrix-assisted laser desorption/ionization (MALDI) often obscures the actual determination of molecular structure. To address the redox reactions in laser desorption/ionization processes, the organic dyes Methylene Blue, Janus Green B, Crystal Violet and Rhodamine B were analyzed by MALDI or by desorption/ionization on porous silicon (DIOS). Susceptibility to reduction in MALDI was dependent on both the reduction potentials of analytes and the molar ratio of analyte to matrix molecules. Addition of Cu(II) ions as an electron scavenger suppressed the reduction of Methylene Blue in MALDI. The results suggested that electron transfer to analytes from the sample target and/or from the matrix contributed to the reduction. In DIOS, the reductions of organic dyes were more prominent than in MALDI, and were not prevented by Cu(II) ion doping, probably due to direct contact of the analytes with silicon which had little electric resistance.

Azo Compounds↗

Analysis of polypropyleneglycols using electrospray ionization mass spectrometry. Effects of cationizing agents on the mass spectra.

In electrospray ionization mass spectrometry (ESI-MS) of polypropyleneglycol (PPG), effects of cationizing agents were examined. When NaI was used as a cationizing agent, the distribution of multiply-charged ions in the spectra was greatly affected by the ratio of cationizing agent and PPG. However, the distribution was not affected by the use of CH(3)COONH(4). With an increase of cone voltage, fragmentation occurred by in-source collision-induced dissociation (CID) when CH(3)COONH(4) was used. On the contrary, no decomposition of the PPG backbone was observed with NaI. Instead, the intensity of the lower-charged ions, whose mass-to-charge (m/z) ratios are larger, increased because of the elimination of Na(+) with increase of cone voltage. Under optimum conditions for ESI-MS analysis, PPGs that have different molecular weights, different initiators or end groups were easily and accurately characterized. A tandem mass spectrometry (MS/MS) study of NH(4)(+) adduct ions of PPG indicated that a vinyl-terminated linear structure is formed at the end group during the fragmentation.

Journal Article↗