PubMed Health⌕ Search

Biomedical subjects

Shouxin Ren

Publications and source records attributed to Shouxin Ren.

2 recordsLinked to original sources

Simultaneous spectrophotometric determination of four metals by two kinds of partial least squares methods.

Simultaneous determination of Ni(II), Cd(II), Cu(II) and Zn(II) was studied by two methods, kernel partial least squares (KPLS) and wavelet packet transform partial least squares (WPTPLS), with xylenol orange and cetyltrimethyl ammonium bromide as reagents in the medium pH = 9.22 borax-hydrochloric acid buffer solution. Two programs, PKPLS and PWPTPLS, were designed to perform the calculations. Data reduction was performed using kernel matrices and wavelet packet transform, respectively. In the KPLS method, the size of the kernel matrix is only dependent on the number of samples, thus the method was suitable for the data matrix with many wavelengths and fewer samples. Wavelet packet representations of signals provide a local time-frequency description, thus in the wavelet packet domain, the quality of the noise removal can be improved. In the WPTPLS by optimization, wavelet function and decomposition level were selected as Daubeches 12 and 5, respectively. Experimental results showed both methods to be successful even where there was severe overlap of spectra.

Cadmium↗

Wavelet packet transform and artificial neural network applied to simultaneous kinetic multicomponent determination.

This paper presents a novel method, named wavelet packet transform based multilayer feedforward neural network with Levenberg-Marquardt and back propagation algorithm (WPTLMBP), developed for simultaneous kinetic determination of Cu(II), Fe(III), and Ni(II). Wavelet packet representations of signals provided a local time-frequency description, thus in the wavelet packet domain the quality of noise removal can be improved. The artificial neural network was applied for non-linear multivariate calibration. In this study, by optimization, wavelet packet function, decomposition level and number of hidden nodes for WPTLMBP method were selected as Db2, 2, and 4 respectively. A program PWPTLMBP was designed to perform simultaneous kinetic determination of Cu(II), Fe(III), and Ni(II). The relative standard error of prediction (RSEP) for all components with WPTLMBP, LM-BP-MLFN, and PLS methods were 6.39, 10.4, and 8.30%, respectively. Experimental results showed the proposed method to be successful and better than the others.

Copper↗