PubMed Health⌕ Search

Biomedical subjects

Shuji Tanada

Publications and source records attributed to Shuji Tanada.

At least 19 recordsLinked to original sources

Cardiac imaging using 256-detector row four-dimensional CT: preliminary clinical report.

PURPOSE: Along with the increase of detector rows on the z-axis and a faster gantry rotation speed, the spatial and temporal resolutions of the multislice computed tomography (CT) have been improved for noninvasive coronary artery imaging. We investigated the feasibility of the second specification prototype 256-detector row four-dimensional CT for assessing coronary artery and cardiac function. MATERIALS AND METHODS: The subjects were five patients with coronary artery disease. Contrast medium (40-60 ml) was intravenously administered at the rate of 3-4 ml/s. The patient's whole heart was scanned for 1.5 s to cover at least one cardiac cycle during breathholding without electrocardiographic gating. Parameters used were 0.5 mm slice thickness, 0.5 s/rotation, 120 Kv, and 350 mA, with a half-scan reconstruction algorithm (temporal resolution 250 ms). Twenty-six transaxial datasets were reconstructed at intervals of 50 ms. RESULTS: The assessability of the coronary arteries in AHA segments 1, 2, 3, 5, 6, 7, 9, and 11 was visually evaluated, resulting in 29 of 32 (90.9%) segments being assessable. Functional assessment was also performed using animated movies without banding artifacts in all cases. CONCLUSIONS: The 256-detector row four-dimensional CT can assess the coronary artery and cardiac function using data during 1.5 s without banding artifacts.

Aged↗

Preliminary study: color map of hepatocellular carcinoma using dynamic contrast-enhanced 256-detector row CT.

To distinguish hepatocellular carcinoma (HCC) from normal liver tissue, a color map was made by dynamic contrast-enhanced 256-detector row CT developed at our institute. Dynamic enhanced CT of the liver of three patients with HCC was studied. The CT has 912 (transverse) x 256 (cranio-caudal) elements, each measuring approximately 0.5 mm x 0.5mm at the center of rotation. Scanning for 10 s (1.0 s/rotation) was started 30 s after intravenous injection of contrast medium. The reconstruction increment was 0.62 mm with a time interval of 0.1s and a matrix size of 512 x 512 x 256. Color maps were generated to show the gradient of the regression line of the time-density change. Due to volume acquisition, the 3D color map can be created using continuous 10-s scanning. The densities of the HCC and liver were decreased and increased during scanning, respectively. The HCC was detected clearly in the color map as a downward-sloping region. Dynamic enhanced 256-detector row CT could be useful for detecting malignant tumors in the liver with a short scan time.

Aged↗

Superiority of synchrony of 256-slice cone beam computed tomography for acquiring pulsating objects. Comparison with conventional multislice computed tomography.

PURPOSE: A prototype 256-slice cone beam computed tomography (CT) provides complete volumetric data within a single gantry rotation (1 s/rotation) with 0.5 mm slice-thickness. MATERIALS AND METHODS: Calcified phantoms (200-400 HU) were attached to the balloon of a pulsating phantom and moved at a rate of 5-90/min. Acquisition was performed during one to-and-fro motion at each pulsation rate without electrocardiogram (ECG)-gating. Each period was divided into 10 phases, and compared to conventional multislice CT scanning without ECG-gating. RESULTS: At 5-20/min, the configuration of calcified phantoms continued to the through-plane without gaps. At 60/min, duplicated calcified phantoms at end-systole and end-diastole were observed without motion. At 90/min, motion could be observed without gaps but was more blurred, and total calcified volume, Agatston scores, mean and max CT values of three phantoms were almost equal compared with those at static state. However, at 60/min, total calcified volume, scores, mean and max CT values of three phantoms were decreased to 64%, 37%, 80% and 56%, respectively, compared with those at static state. In multislice CT, even at lower rates, there were gaps in the through-plane. At 60/min, total calcified volume, scores, mean and max CT values of three phantoms were decreased to only 8%, 3%, 79% and 53%, respectively, compared with static state. CONCLUSION: This new prototype's unique character (synchrony) enables the acquisition of pulsating objects. These can be acquired without gaps in the through-plane even in the absence of ECG-gating. However, its present temporal resolution only permits accurate quantitative evaluation of calcium up to 20/min.

Electrocardiography↗

Noise properties for three weighted Feldkamp algorithms using a 256-detecotor row CT-scanner: case study for hepatic volumetric cine imaging.

In cone-beam geometry, image quality may be degraded or artifacts may occur if the cone angle is substantially wide. This is because a cone-beam scan along a circular orbit does not collect the complete set of data required to make an exact reconstruction of all volumetric data. To increase temporal resolution and thus image quality in cone-beam geometry, Silver proposed the new half-scan algorithm (NHS-FDK), which extends Parker's weighting function (HS-FDK) by utilizing a larger range up to 2pi. Here, we evaluated these algorithms for hepatic contrast-enhanced CT in cine scan mode using a 256-detector row CT. The full-scan (FS-FDK) images show uniform distribution of the image noise and CT-number uniformity. Image noise and CT-number uniformity with HS-FDK and NHS-FDK images follow the initial projection angle. HS-FDK images therefore have more changeable higher intensity (brighter) and a lower intensity (darker) areas than respective FS-FDK and NHS-FDK images. We concluded that, considering the trade-off between image quality and temporal resolution, the NHS-FDK algorithm is useful in volumetric cine imaging for the abdomen.

Aged↗

Properties of the prototype 256-row (cone beam) CT scanner.

We evaluated Feldkamp artifacts, which are specific to cone-beam computed tomography (CT), in phantom and clinical studies using the 256-multidetector-row CT (256MDCT), and compared the reconstruction accuracy of axial and helical scans. Image noise, slice sensitivity profile (SSP) and artifacts with the 256MDCT were evaluated using a phantom, and the results were compared to those of a 64MDCT. We also examined chest and abdomen scans produced with the 256MDCT in volunteers. For the axial scan, Feldkamp artifacts were visualized as high-frequency streak-like artifacts that are oriented horizontally at the edge of the scan region in the phantom study. Similar results were obtained with the volunteers in soft-tissue regions near either bony structures or air pockets. Feldkamp artifacts with the 256MDCT can lead to misdiagnosis if not correctly identified and minimized via helical scanning. Image noise was less for axial than helical scans, while SSP was better with helical than axial scans. Feldkamp artifacts observed in the 256MDCT images, however, did not generally affect the interpretation of images. The 256MDCT promises more accurate diagnosis, and will provide volumetric cine images of wider cranio-caudal coverage, enabling new applications of CT.

Adult↗

A dose-finding study of duloxetine based on serotonin transporter occupancy.

RATIONALE: Positron emission tomography (PET) has been utilized for determining the dosage of antipsychotic drugs. To evaluate the dosage of antidepressants such as selective serotonin reuptake inhibitors, serotonin transporter occupancy (5-HTT) is also a useful index. OBJECTIVES: We investigated the degree of 5-HTT occupancy with different doses of the antidepressant duloxetine and the time-course of 5-HTT occupancy using PET. METHODS: PET scans with [11C]DASB were performed before and after a single administration of duloxetine (5-60 mg), and three consecutive scans were performed after a single dose or repeated doses of 60 mg of duloxetine. RESULTS: 5-HTT occupancies by duloxetine were increased by 35.3 to 86.5% with dose and plasma concentration increments. The ED50 value of 5-HTT occupancy was 7.9 mg for dose and 3.7 ng/ml for plasma concentration. In the time-course of 5-HTT occupancy, mean occupancies were 81.8% at 6 h, 71.9% at 25 h, and 44.9% at 53 h after a single administration, and 84.3% at 6 h, 71.9% at 49 h, and 47.1% at 78 h after repeated administrations. CONCLUSIONS: Based on 5-HTT occupancy, 40 mg and more of duloxetine was needed to attain 80% occupancy, and 60 mg of duloxetine could maintain a high level of 5-HTT occupancy with a once-a-day administration schedule.

Adult↗

Physical evaluation of the weighted Feldkamp algorithms applied to the 256-detector row CT scanner for volumetric cine imaging.

RATIONALE AND OBJECTIVES: To improve effective scan time and image quality in cone-beam computed tomography (CT), Parker's weighting function (half scan [HS]-Feldkamp-Davis-Kress [FDK]) extended to a larger range up to 2pi was proposed as new half-scan algorithm (NHS-FDK). We conducted a practical physical evaluation of NHS-FDK and HS-FDK using 256-detector row CT. MATERIALS AND METHODS: Three types of weighting function (full-scan [FS-FDK], HS-FDK, and NHS-FDK) were evaluated by using 256-detector row CT for five variables, ie, point spread function, image noise, CT number uniformity, Feldkamp artifact, temporal resolution, and clinical evaluation. RESULTS: Image noise, Feldkamp artifact, and temporal resolution were dependent on weighting function. Image noise magnitude was independent of projection angle for all regions of interest with FS-FDK, but showed a symmetric pattern with projection angle with HS-FDK and NHS-FDK. With regard to temporal resolution, NHS-FDK did not remove the motion artifact in the heart except in such slower motion organs as the pulmonary vessels, whereas HS-FDK reduced the motion artifact in the heart. HS-FDK had an even more incomplete data region in the Radon space than FS-FDK, suggesting that it would provide poor image quality distant to the midplane in the longitudinal direction. In practical testing in human subjects, HS-FDK showed inferior performance in all variables except temporal resolution. CONCLUSION: Despite its inferiority to FS-FDK for static objects, HS-FDK may be useful in chest imaging. Contrary to previous findings using static images, NHS-FDK failed to show advantages over HS-FDK or FS-FDK in a moving phantom and human subjects.

Adult↗

Molecular therapy of human neuroblastoma cells using Auger electrons of 111In-labeled N-myc antisense oligonucleotides.

UNLABELLED: Auger electrons can create breaks in nucleic acids, giving them possible therapeutic utility. We investigated the therapeutic effect of Auger electrons emitted by 111In-labeled phosphorothioate antisense oligonucleotides on human neuroblastoma cells in which N-myc was overexpressed. METHODS: Human SK-N-DZ neuroblastoma cells (5 x 10(6) cells) were treated with cationic reverse-phase evaporation vesicles (REVs) encapsulating 111In-labeled antisense (40 MBq/2 nmol of oligonucleotides/mumol of total phospholipids) that had an average diameter of 250 nm. Hybridization of the radiolabeled oligonucleotides with N-myc messenger RNA (mRNA), N-myc expression, and cell proliferation were investigated. The tumorigenicity of treated cells was analyzed in nude mice. Nonradiolabeled antisense, 111In-labeled sense, or empty cationic REVs were used as controls. RESULTS: 111In-Labeled antisense, which hybridized with N-myc mRNA, was detected in cells at 12 and 24 h after the initiation of treatment. Reduced N-myc expression and inhibited cell proliferation were shown in the same cells at 48 h after the completion of treatment. N-myc expression-suppressed cells produced intraperitoneal tumors in nude mice, but the average weight of the tumors was lower than that of tumors in control mice. CONCLUSION: Auger electrons emitted from 111In in close proximity to their target N-myc mRNA may prolong the time to cell proliferation in human neuroblastoma cells due to inhibition of the translation of N-myc. Auger electron therapy therefore has potential as an internally delivered molecular radiotherapy targeting the mRNA of a tumor cell.

Animals↗

Optimizing T2-weighted magnetic resonance sequences for surface coil microimaging of the eye with regard to lid, eyeball and head moving artifacts.

PURPOSE: To acquire high-resolution magnetic resonance (MR) images, we developed a new blinking artifact reduced pulse (BARP) sequence with a surface coil specialized for microscopic imaging (47 mm in diameter). MATERIALS AND METHODS: To reduce eye movement, we ascertained that the subjects' eyes were kept open and fixated to the target in the 1.5-T MR gantry. To reduce motion artifacts from blinking, we inserted rest periods for blinking (1.5 s within every 5 s) during MR scanning (T2-weighted fast spin echo; repetition time, 5 s; echo time, 100 ms; echo train, 11; matrix, 256 x 128; field of view, 5 cm; 1-mm thickness x 30 slices). Three scans (100 s x 3) were performed for each normal subject, and they were added together after automatic adjustment for location to reduce quality loss caused by head motion. RESULTS: T2-weighted MR images were acquired with a high resolution and a high signal-to-noise ratio. Motion artifacts were reduced with BARP, as compared with those with random blinking. Intraocular structures such as the iris and ciliary muscles were clearly visualized. Because the whole eye can be covered with a 1-mm thickness by this method, three-dimensional maps can easily be generated from the obtained images. CONCLUSION: The application of BARP with a surface coil of the human eye might become a useful and widely adopted procedure for MR microimaging.

Algorithms↗

Functional network in the prefrontal cortex during episodic memory retrieval.

A recent consistent finding in neuroimaging studies of human memory is that the prefrontal cortex (PFC) is activated during episodic memory retrieval. To date, however, there has been no direct evidence to explain how activity in the right and left PFC and in the anterior and posterior PFC are functionally interconnected. The goal of the present study was to obtain such evidence by event-related functional magnetic resonance imaging (MRI) and the functional connectivity method. Subjects were first asked to try to remember a series of associate-word lists outside the MRI scanner in preparation for a later recognition test. In the MRI scanning phase, they were asked to make recognition judgments in regard to old words, semantically related lure words, and unrelated new words. The analysis of functional connectivity revealed that the posterior PFC in each hemisphere had strong functional interconnections with the contralateral posterior PFC, whereas the anterior PFC in each hemisphere had only weak functional interconnections with the contralateral anterior PFC. No strong functional interconnections were found between the anterior and posterior PFC in either hemisphere. These findings support the hypothesis of an associative contribution of the bilateral posterior PFC to episodic memory retrieval and a dissociative contribution of the bilateral anterior PFC.

Adult↗

Clinical potentials of the prototype 256-detector row CT-scanner.

RATIONALE AND OBJECTIVES: To evaluate clinical potentials of the 256-detector row computed tomography (CT) in healthy volunteers. MATERIALS AND METHODS: Eight healthy males (22-63 years) participated in the present study. They underwent a noncontrast-enhanced examination with a contiguous axial scan mode either for head, chest, abdomen, or pelvis. Dose was the same as routinely used for multislice CT examinations. Image quality was interpreted by three board-certified radiologists. RESULTS: With the 256-detector row CT, 0.5-0.8 mm isotropic volumetric data could be acquired in one rotation. Main promising findings are as follows. Three-dimensional structures were visualized clearly in the multiple planes without secondary reconstruction, whereas the axial images had nearly the same image quality as conventional CT. Shading or streak artifacts were observed at the edge of the scan region. The latter are also known as Feldkamp artifacts. Coronal chest images showed a motion artifact from the heart beating. CONCLUSION: The 256-detector row CT promises to be useful in clinical applications with its ability to provide three-dimensional visualization of fine structures. The Feldkamp artifacts observed did not generally affect interpretation of images. Investigations are now continuing on image correction along the craniocaudal direction to improve the overall image quality.

Adult↗

Estimation of plasma IC50 of donepezil hydrochloride for brain acetylcholinesterase inhibition in monkey using N-[11C]methylpiperidin-4-yl acetate ([11C]MP4A) and PET.

Donepezil hydrochloride is a potent and selective inhibitor for brain acetylcholinesterase (AChE) and is currently used worldwide for the treatment of Alzheimer's disease. Until now, there is no in vivo study on the relation between the plasma concentration and the brain AChE inhibition. The purpose of this study was to estimate in vivo plasma IC(50) of donepezil in living monkeys by measuring plasma donepezil concentration (LC/MS/MS) and brain AChE activity with positron emission tomography (PET) and N-[(11)C]methylpiperidin-4-yl acetate, which is an acetylcholine analog recently developed by us for quantifying in vivo brain AChE activity. PET scans with donepezil at two doses, 100 microg/kg (donepezil-1; N=5) or 250 microg/kg (donepezil-2; N=5), were performed using the same monkeys at 4-week intervals. Before each PET scan, baseline PET scans (N=10 in total) were performed without donepezil. The plasma donepezil concentrations 14 min after intravenous injection were proportional to the doses, 17.2+/-2.9 ng/ml (donepezil-1) and 44.0+/-5.0 ng/ml (donepezil-2), and the mean AChE inhibitions in four neocortical regions as evaluated by PET were also dose-dependent, 27% (donepezil-1) and 53% (donepezil-2). In IC(50) estimation, measured plasma donepezil concentrations were corrected for the change during PET scan. The IC(50) values (estimate+/-SE) were 42+/-9.0 (ng/ml; donepezil-1), 34+/-3.2 (donepezil-2), and 37+/-4.1 (combined data). The present method may be useful for in vivo evaluation of other AChE inhibitors and novel drugs.

Acetylcholinesterase↗

Cardiovascular circulation and hepatic perfusion of pigs in 4-dimensional films evaluated by 256-slice cone-beam computed tomography.

BACKGROUND: In both cardiac and hepatic disorders it is desirable to accurately visualize the direction and scale of blood flow in the whole organ in pulsating 3-dimensional (D) images, which are known as 4-D images. METHODS AND RESULTS: The present study used 256-slice cone-beam computed tomography (CT) (Athena, Sony-Toshiba) at one rotation per second and a section thickness of 0.5 mm to show the dynamics of cardiovascular circulation and hepatic perfusion by contrast injection in 4-D films of pigs. Four pigs (20 kg each) were anesthetized with isoflurane. The distal tips of the catheters were positioned in the inferior vena cava (IVC) (pigs 1-3) and in the proper hepatic artery (pig 4). Volumetric scanning and injection of contrast material were started simultaneously and continued for 25 s with image reconstruction at 1-s intervals. In pigs 1-3, 4-D filming revealed the dynamics of cardiovascular circulation, first in the IVC, followed by the right ventricle and pulmonary artery, then the left ventricle, left atrium, pulmonary vein, and finally, the right heart disappeared and only the left heart and aorta remained visible. In pig 4, the hepatic arterial trees, followed by the venous trees, could be easily visualized in turn on the 4-D images. CONCLUSIONS: This technology successfully demonstrated cardiovascular circulation and hepatic perfusion in 4-D and will have clinical applicability.

Animals↗

Clinical potentials for dynamic contrast-enhanced hepatic volumetric cine imaging with the prototype 256-MDCT scanner.

OBJECTIVE: To achieve dynamic contrast-enhanced hepatic volumetric cine imaging, we developed a prototype 256-MDCT scanner. This study examined the feasibility of the technique for human hepatic imaging in three hepatocellular carcinoma patients. CONCLUSION: Volumetric cine imaging successfully visualized dynamic contrast enhancement of the hepatocellular carcinoma. It is helpful to evaluate the phase of contrast enhancement or for functional studies of the head, renal artery, coronary artery, and liver.

Aged↗

Carbon-11-methionine positron emission tomography imaging of chordoma.

OBJECTIVE: Chordoma is a rare malignant bone tumor that arises from notochord remnants. This is the first trial to investigate the utility of (11)C-methionine (MET) positron emission tomography (PET) in the imaging of chordoma before and after carbon-ion radiotherapy (CIRT). DESIGN AND PATIENTS: Fifteen patients with chordoma were investigated with MET-PET before and after CIRT and the findings analyzed visually and quantitatively. Tumor MET uptake was evaluated by tumor-to-nontumor ratio (T/N ratio). RESULTS: In 12 (80%) patients chordoma was clearly visible in the baseline MET-PET study with a mean T/N ratio of 3.3+/-1.7. The MET uptake decreased significantly to 2.3+/-1.4 after CIRT ( P<0.05). A significant reduction in tumor MET uptake of 24% was observed after CIRT. Fourteen (93%) patients showed no local recurrence after CIRT with a median follow-up time of 20 months. CONCLUSION: This study has demonstrated that MET-PET is feasible for imaging of chordoma. MET-PET could provide important tumor metabolic information for the therapeutic monitoring of chordoma after CIRT.

Aged↗

[(11)C]methionine positron emission tomography and survival in patients with bone and soft tissue sarcomas treated by carbon ion radiotherapy.

PURPOSE: The development of the novel carbon ion radiotherapy (CIRT) in the treatment of refractory cancers has resulted in the need for a way to accurately evaluate patient prognosis. We evaluated whether L-[methyl-(11)C]-methionine (MET) uptake and its change after CIRT were the early survival predictors in patients with unresectable bone and soft tissue sarcomas. EXPERIMENTAL DESIGN: MET positron emission tomography was prospectively performed in 62 patients with unresectable bone and soft tissue sarcomas before and within 1 month after CIRT. Tumor MET uptake was measured with the semiquantitative tumor:nontumor ratio (T/N ratio). The MET uptake in the tumor and relevant clinical parameters were entered into univariate and multivariate survival analysis. RESULTS: The overall median survival time was 20 months. Patients with a baseline T/N ratio of 6 (2-year survival rate: 69.4% versus 32.3%; P = 0.01). Patients with a post-CIRT ratio of 4.4 (2-year survival rate: 63.7% versus 41.3%; P = 0.01). A significant higher survival rate was observed in patients with post-therapeutic MET uptake change of >30% than patients in lower change group (2-year survival rate: 74.6% versus 41.6%; P = 0.049). The multivariate analysis showed that both baseline and post-CIRT T/N ratio were statistically significant independent predictors of patient survival. Tumors with larger T/N ratio had a significantly poorer prognosis. CONCLUSIONS: MET uptake as measured by either baseline or post-CIRT T/N ratio was an independent predictor of survival in patients with bone and soft tissue sarcomas treated by carbon ion radiotherapy, whereas post-therapeutic MET uptake change might have potential value for the same purpose.

Adolescent↗

A simple method for the detection of abnormal brain regions in Alzheimer's disease patients using [11C]MP4A: comparison with [123I]IMP SPECT.

We have developed a radiolabeled lipophilic acetylcholine analogue, N-[11C]methylpiperidin-4-yl acetate ([11C]MP4A) to measure brain acetylcholinesterase (AChE) activity by positron emission tomography (PET) in vivo. Aiming to develop a new SPECT tracer similar to MP4A, we first proposed a simple method for diagnosing Alzheimer's disease (AD) using [11C]MP4A PET. We performed [11C]MP4A PET and N-isopropyl [123I]iodoamphetamine ([123I]IMP) SPECT in 13 patients with AD and in 17 normal controls (NC). We calculated the ratio of radioactivity of the cortical region of interest (ROI) to that of the cerebellum measured with [11C]MP4A PET (MP4A ratio) and the ratio of regional cerebral blood flow (rCBF) to that of the cerebellum measured with [123I]IMP SPECT (IMP ratio). Eleven cortical ROIs were placed in the frontal, sensorimotor, temporal, parietal, and occipital cortices in both hemispheres and in the posterior cingulate cortex, and z-score was calculated in each ROI in patients with AD compared with NC. When the z-score was 2 or more in a ROI, it was defined as a positive ROI. When a patient had 3 or more positive ROIs, the patient was diagnosed as having AD. The reduction in the MP4A ratio was greater than that in the IMP ratio in all cortical ROIs except for in the right parietal cortex and cingulate cortex in patients with AD. MP4A ratio method showed 92% sensitivity and the IMP ratio method 69% sensitivity for the diagnosis of AD. These results encourage us to develop a new SPECT tracer similar to MP4A for the diagnosis of AD.

Acetates↗