PubMed Health⌕ Search

Biomedical subjects

Sid P Bacon

Publications and source records attributed to Sid P Bacon.

16 recordsLinked to original sources

Measuring the critical band for speech.

The current experiments were designed to measure the frequency resolution employed by listeners during the perception of everyday sentences. Speech bands having nearly vertical filter slopes and narrow bandwidths were sharply partitioned into various numbers of equal log- or ERBN-width subbands. The temporal envelope from each partition was used to amplitude modulate a corresponding band of low-noise noise, and the modulated carriers were combined and presented to normal-hearing listeners. Intelligibility increased and reached asymptote as the number of partitions increased. In the mid- and high-frequency regions of the speech spectrum, the partition bandwidth corresponding to asymptotic performance matched current estimates of psychophysical tuning across a number of conditions. These results indicate that, in these regions, the critical band for speech matches the critical band measured using traditional psychoacoustic methods and nonspeech stimuli. However, in the low-frequency region, partition bandwidths at asymptote were somewhat narrower than would be predicted based upon psychophysical tuning. It is concluded that, overall, current estimates of psychophysical tuning represent reasonably well the ability of listeners to extract spectral detail from running speech.

Adolescent↗

The effect of a steep high-frequency hearing loss on growth-of-masking functions in simultaneous masking for f(m)<f(s).

In normal-hearing subjects, the slope of the growth-of-masking (GOM) function obtained in simultaneous masking when the masker frequency (f(m)) is much less than the signal frequency (f(s)) often changes from a value near 2.0 to a value near 1.0 at high levels. The purpose of the present study was to evaluate whether this change in slope reflects a basal shift in the peak of the signal's basilar-membrane vibration pattern. To discourage the use of basally shifted peak excitation, GOM functions were obtained in seven subjects with a precipitously sloping high-frequency hearing loss. The signal was located at the normal-hearing edge of the loss, and the masker was located 3 equivalent rectangular bandwidths below f(s). In addition, GOM functions for an f(s) of 2000 Hz were obtained in four subjects with normal hearing, either "in quiet" or in the presence of a restrictor tone with a frequency of 2400 or 2600 Hz and a level of 90 dB SPL. Overall, the results generally are not consistent with the change in slope at high levels being due to a basal shift in the peak of the signal's basilar-membrane vibration pattern. Instead, the results are consistent with a decrease in compression at high input levels at the place corresponding to f(s).

Acoustic Stimulation↗

Compression estimates using behavioral and otoacoustic emission measures.

Cochlear compression in normal-hearing listeners was estimated at octave frequencies from 250 to 4000 Hz using a forward-masking paradigm. Temporal masking curves (TMCs) for a 10-dB SL signal were obtained with two maskers -- one equal in frequency to the signal and another an octave below the signal. The ratio of the slope of the off-frequency function to that of the mid-level portion of the on-frequency function was computed as an estimate of the amount of compression at each frequency. Compression was less frequency selective at low frequencies, so an average of the off-frequency slopes at high frequencies (1000, 2000, and 4000 Hz) was used in computing the ratio for each signal frequency. Results indicated strong compression (approximately 0.15-0.30) at all frequencies using the averaged off-frequency slopes, indicating little difference in compression across frequencies. Distortion product otoacoustic emission (DPOAE) input-output (I-O) functions were obtained for each subject at 1000, 2000, and 4000 Hz. The slopes of the DPOAE I-O functions and the psychophysical growth rates were similar to one another, reinforcing the assumption that the forward-masking procedure is providing an estimate of cochlear compression, at least at frequencies from 1000 to 4000 Hz.

Acoustic Impedance Tests↗

An across-frequency processing deficit in listeners with hearing impairment is supported by acoustic correlation.

It has been recently suggested that listeners having a sensorineural hearing impairment (HI) may possess a deficit in their ability to integrate speech information across different frequencies. When presented with a task that required across-frequency integration of speech patterns, listeners with HI performed more poorly than their normal-hearing (NH) counterparts (E. W. Healy & S. P. Bacon, 2002; C. W. Turner, S.-L. Chi, & S. Flock, 1999). E. W. Healy and S. P. Bacon (2002) also showed that performance of the listeners with HI fell more steeply when increasing amounts of temporal asynchrony were introduced to the pair of widely separated patterns. In the current study, the correlations between the fluctuating envelopes of the acoustic stimuli were calculated, both when the patterns were aligned and at various between-band asynchronies. It was found that the rate at which acoustic correlation fell as a function of asynchrony closely matched the rate at which intelligibility fell for the NH listeners. However, the intelligibility scores produced by the listeners with HI fell more steeply than the acoustic analysis would suggest. Thus, these data provide additional support for the hypothesis that individuals having sensorineural HI may have a deficit in their ability to integrate speech information present at different frequencies.

Auditory Perceptual Disorders↗

Psychophysical estimates of nonlinear cochlear processing in younger and older listeners.

The primary goal of this project was to compare the performance of younger and older listeners on a number of psychophysical measures thought to be influenced by nonlinear cochlear processing. Younger (mean of 25.6 years) and older (mean of 63.8 years) listeners with normal hearing were matched (within 5 dB) according to their quiet thresholds at the two test frequencies of 1200 and 2400 Hz. They were similarly matched at the adjacent octave frequencies of 600 and 4800 Hz (within 5 dB at one and 9 dB at the other). Performance was compared on measures of auditory filter shape, psychophysical suppression, and growth of forward masking. There was no difference between the two age groups on these psychophysical estimates reflecting nonlinear processing, suggesting that aging per se does not affect the cochlear nonlinearity, at least for the ages sampled here. The results did, however, consistently demonstrate an age-related increase in the susceptibility to forward masking.

Acoustic Stimulation↗

Temporal effects in simultaneous masking with on- and off-frequency noise maskers: effects of signal frequency and masker level.

Temporal effects in simultaneous masking were measured as a function of masker level for an on-frequency broadband masker and an off-frequency narrow-band masker for signal frequencies of 750, 1730, and 4000 Hz. The on-frequency masker was 10 equivalent rectangular bandwidths (ERBs) wide and centered at the signal frequency; the off-frequency masker was 500 Hz wide and its lower frequency edge was 1.038 ERBs higher in frequency than the signal. The primary goal of the study was to determine whether previously observed differences regarding the effects of signal frequency and masker level on the temporal effect for these two different types of masker might be due to considerably different signal levels at threshold. Despite similar masked thresholds, the effects of signal frequency and masker level in the present study were different for the two masker types. The temporal effect was significant for the two highest frequencies and absent for the lowest frequency in the presence of the broadband masker, but was more or less independent of frequency for the narrow-band masker. The temporal effect increased but then decreased as a function of level for the broadband masker (at the two higher signal frequencies, where there was a temporal effect), but increased and reached an asymptote for the narrow-band masker. Despite the different effects of signal frequency and masker level, the temporal effects for both types of masker can be understood in terms of a basilar-membrane input-output function that becomes more linear during the course of masker stimulation.

Acoustic Stimulation↗

Relative importance of temporal information in various frequency regions for consonant identification in quiet and in noise.

The relative importance of temporal information in broad spectral regions for consonant identification was assessed in normal-hearing listeners. For the purpose of forcing listeners to use primarily temporal-envelope cues, speech sounds were spectrally degraded using four-noise-band vocoder processing Frequency-weighting functions were determined using two methods. The first method consisted of measuring the intelligibility of speech with a hole in the spectrum either in quiet or in noise. The second method consisted of correlating performance with the randomly and independently varied signal-to-noise ratio within each band. Results demonstrated that all bands contributed equally to consonant identification when presented in quiet. In noise, however, both methods indicated that listeners consistently placed relatively more weight upon the highest frequency band. It is proposed that the explanation for the difference in results between quiet and noise relates to the shape of the modulation spectra in adjacent frequency bands. Overall, the results suggest that normal-hearing listeners use a common listening strategy in a given condition. However, this strategy may be influenced by the competing sounds, and thus may vary according to the context. Some implications of the results for cochlear implantees and hearing-impaired listeners are discussed.

Acoustic Stimulation↗

Learning in discrimination of frequency or modulation rate: generalization to fundamental frequency discrimination.

Fifteen initially inexperienced subjects were trained for 4 weeks (12 2-h sessions) in frequency discrimination with pure tones around 88, 250, or 1605 Hz, or amplitude modulation rate discrimination of noise bands, using modulation rates around 88 or 250 Hz. Before, in the middle of, and after this training period, pure-tone frequency discrimination thresholds (DLFs), harmonic complex tone fundamental frequency discrimination thresholds (DLF0s), and amplitude modulation rate discrimination thresholds (DLFMs) were measured in several conditions including the trained one. Training in pure-tone frequency discrimination resulted in significantly larger improvements in DLF0s when the test complexes contained resolved harmonics than when they were composed of unresolved harmonics. This result supports the hypothesis that the discrimination of the F0 of resolved harmonics shares common underlying mechanisms with the frequency discrimination of pure tones. Training in rate discrimination did not result in larger DLF0 improvements for unresolved than for resolved harmonics.

Acoustic Stimulation↗

Cochlear compression: perceptual measures and implications for normal and impaired hearing.

This article provides a review of recent developments in our understanding of how cochlear nonlinearity affects sound perception and how a loss of the nonlinearity associated with cochlear hearing impairment changes the way sounds are perceived. The response of the healthy mammalian basilar membrane (BM) to sound is sharply tuned, highly nonlinear, and compressive. Damage to the outer hair cells (OHCs) results in changes to all three attributes: in the case of total OHC loss, the response of the BM becomes broadly tuned and linear. Many of the differences in auditory perception and performance between normal-hearing and hearing-impaired listeners can be explained in terms of these changes in BM response. Effects that can be accounted for in this way include poorer audiometric thresholds, loudness recruitment, reduced frequency selectivity, and changes in apparent temporal processing. All these effects can influence the ability of hearing-impaired listeners to perceive speech, especially in complex acoustic backgrounds. A number of behavioral methods have been proposed to estimate cochlear nonlinearity in individual listeners. By separating the effects of cochlear nonlinearity from other aspects of hearing impairment, such methods may contribute towards identifying the different physiological mechanisms responsible for hearing loss in individual patients. This in turn may lead to more accurate diagnoses and more effective hearing-aid fitting for individual patients. A remaining challenge is to devise a behavioral measure that is sufficiently accurate and efficient to be used in a clinical setting.

Acoustic Stimulation↗

Effectiveness of narrow-band versus tonal off-frequency maskers.

The present study was a follow-up to a pilot study in which it was found that a 500-Hz-wide narrow-band noise (NBN) masker produced more masking than a tonal (T) masker for signal frequencies both above and below the masker frequency. The aim of the present study was to determine to what extent these results were influenced by an interaction of the relatively rapid temporal envelope fluctuations of the NBN and the short (10-ms) duration of the signal. In the first experiment, the masking produced by a regular NBN, a low-noise noise (LNN), and a T was compared. The LNN produced less masking than the NBN, and about as much as the T, suggesting that the inherent amplitude fluctuations in the NBN were largely responsible for the greater masking produced by that masker. In the second experiment, the masking produced by a regular NBN was compared with that by a T for a signal duration of 10 or 200 ms. The difference in masking between the two maskers was reduced or eliminated when the signal duration was 200 ms, because the threshold in the presence of the NBN masker decreased more with increasing signal duration. This could reflect a decreased "confusion" between the signal and the inherent fluctuations of the NBN masker.

Acoustic Stimulation↗

Modulation detection interference in listeners with normal and impaired hearing.

Listeners were asked to detect amplitude modulation (AM) of a target (or signal) carrier that was presented in isolation or in the presence of an additional (masker) carrier. The signal was modulated at a rate of 10 Hz, and the masker was unmodulated or was modulated at a rate of 2, 10, or 40 Hz. Nine listeners had normal hearing, 4 had a bilateral hearing loss, and 4 had a unilateral hearing loss; those with a unilateral loss were tested in both ears. The listeners with a hearing loss had normal hearing at 1 kHz and a 30- to 40-dB loss at 4 kHz. The carrier frequencies were 984 and 3952 Hz. In one set of conditions, the lower frequency carrier was the signal and the higher frequency carrier was the masker. In the other set, the reverse was true. For the impaired ears, the carriers were presented at 70 dB SPL. For the normal ears, either the carriers were both presented at 70 dB SPL or the higher frequency carrier was reduced to 40 dB SPL to simulate the lower sensation level experienced by the impaired ears. There was considerable individual variability in the results, and there was no clear effect of hearing loss. These results suggest that a mild, presumably cochlear hearing loss does not affect the ability to process AM in one frequency region in the presence of competing AM from another region.

Acoustic Impedance Tests↗

Across-frequency comparison of temporal speech information by listeners with normal and impaired hearing.

Listeners with normal hearing (NH) and with sensorineural hearing impairment (HI) were tested on a speech-recognition task requiring across-frequency integration of temporal speech information. Listeners with NH correctly identified a majority of key words in everyday sentences when presented with a synchronous pair of speech-modulated tones at 750 and 3,000 Hz. They could tolerate small amounts (12.5 ms) of across-frequency asynchrony, but performance fell as the delay between bands was increased to 100 ms. Listeners with HI performed more poorly than those with NH when presented with synchronous across-frequency information. Further, performance of listeners with HI fell as a function of asynchrony more steeply than that of their NH counterparts. These results suggest that listeners with HI have particular difficulty comparing and effectively processing temporal speech information at different frequencies. The increased influence of asynchrony indicates that these listeners are especially hindered by slight disruptions in across-frequency information, which implies a less robust comparison mechanism. The results could not be attributed to differences in signal or sensation level, or in listener age, but instead appear to be related to the degree of hearing loss. This across-frequency deficit is unlikely to be attributed to known processing difficulties and may exist in addition to other known disruptions.

Aged↗

Auditory stream segregation on the basis of amplitude-modulation rate.

In this study, auditory stream segregation based on differences in the rate of envelope fluctuations--in the absence of spectral and temporal fine structure cues--was tested. The temporal sequences to segregate were composed of fully amplitude-modulated (AM) bursts of broadband noises A and B. All sequences were built by the reiteration of a ABA triplet where A modulation rate was fixed at 100 Hz and B modulation rate was variable. The first experiment was devoted to measuring the threshold difference in AM rate leading subjects to perceive the sequence as two streams as opposed to just one. The results of this first experiment revealed that subjects generally perceived the sequences as a single perceptual stream when the difference in AM rate between the A and B noises was smaller than 0.75 oct, and as two streams when the difference was larger than about 1.00 oct. These streaming thresholds were found to be substantially larger than, and not related to, the subjects' modulation-rate discrimination thresholds. The results of a second experiment demonstrated that AM-rate-based streaming was adversely affected by decreases in AM depth, but that segregation remained possible as long as the AM of either the A or B noises was above the subject's AM-detection threshold. The results of a third experiment indicated that AM-rate-based streaming effects were still observed when the modulations applied to the A and B noises were set individually, either at a constant level in dB above AM-detection threshold, or at levels at which they were of the same perceived strength. This finding suggests that AM-rate-based streaming is not necessarily mediated by perceived differences in AM depth. Altogether, the results of this study indicate that sequential sounds can be segregated on the sole basis of differences in the rate of their temporal fluctuations in the absence of other temporal or spectral cues.

Adult↗

Effects of signal delay on auditory filter shapes derived from psychophysical tuning curves and notched-noise data obtained in simultaneous masking.

Psychophysical tuning curves (PTCs) measured in simultaneous masking usually sharpen as a short duration signal is moved from the onset to the temporal center of a longer duration masker. Filter shapes derived from notched-noise maskers have not consistently shown this effect. One possible explanation for this difference is that the signal level is fixed in the PTC paradigm, whereas the masker level is usually fixed in the notched-noise paradigm. In the present study, the signal level was fixed at 10 dB SL in both paradigms. The signal was 20 ms in duration, and presented at the onset or temporal center of the 400-ms masker. The masker was a pure tone presented in quiet (PTC) or in the presence of a pure-tone "restrictor" intended to limit off-frequency listening (PTCr), or it was a noise with a spectral notch placed symmetrically or asymmetrically about the 2-kHz signal frequency. Filter shapes were derived from the PTC, PTCr, and notched-noise data using the roex (p, w, t) model. The effects of signal delay and masking paradigm on filter bandwidth were analyzed with a two-factor repeated-measures ANOVA. There was a significant effect of signal delay (the filters sharpened with time) and masking paradigm (the filters derived from the notched-noise data were significantly wider than those derived from either of the PTC measurements, which did not differ from one another). Although the interaction between delay and paradigm was not significant, the filter derived from the notched-noise data sharpened more with time than did the other filters, and thus the bandwidth of the filters from the three paradigms were more similar at the longer delay than at the shorter delay. It is likely that the tuning-curve and notched-noise paradigms measure the same underlying filtering, but that various other factors contribute differentially to the derived filter shapes.

Adult↗